Raypak 751 Pool Heating, Automatic Chlorinators and Chemical Feeders, Winterizing Your Heater

Page 19

POOL HEATING

CAUTION: Power to the heater should be interlocked with the main system pump to make sure the heater does not fire without the main system pump in operation. Improper flow control can damage the heater. Uncontrolled flow (too high) or restricted flow (too low) can seriously affect heater operation. Follow these instructions to make sure your heater is properly installed.

The ADB unit is equipped with an external pump and bypass arrangement that blends outlet water with the inlet to increase the inlet water temperature, thereby reducing the likelihood of condensation forming on the heat exchanger. The pump also serves to circulate water through the heater form the main system piping.

CAUTION: ADB bypass piping should be copper and/or CPVC. PVC piping should NOT be used.

To complete the installation of the pool heater, the pool thermostat needs to be installed in the main return water line. This will ensure that the heater will be ener- gized at the right time. If the main water line is too far away from the heater and the capillary bulb will not reach it, locate the pool thermostat adjacent to the main line and run wires back to the heater. See Figure 13 and 14.

Adjustment of the bypass valve is critical to proper operation of the heater. The bypass valve should be adjusted to achieve a minimum inlet water tempera- ture of 105°F and an outlet water temperature of 125°F. When starting with a cold pool, make initial adjustments. Make final adjustments when pool water approaches desired temperature. Refer to Table G for flow rates.

Automatic Chlorinators and Chemical Feeders

All chemicals must be introduced and completely dilut- ed into the pool or spa water before being circulated through the heater. Do not place chlorine tablets or bromine sticks in the skimmer. High chemical concen- trations will result when the pump is not running (i.e. overnight).

Chlorinators must feed downstream of the heater and have an anti-siphoning device to prevent chemical backup into the heater when the pump is shut off.

NOTE: High chemical concentrates from feeders and chlorinators that are out of adjustment will cause very rapid corrosion to the heat exchanger in the heater. Such damage is not covered under the warranty.

Winterizing Your Heater

When heaters installed outdoors in freezing climate areas are to be shut down for the winter, please observe the following procedure:

1.Turn off manual main gas and main gas shut off. Remove the drain plug or open the drain valves located on the bottom header.

Pool and Spa Water Chemistry

NOTE: Chemical imbalance can cause severe damage to your heater and associated equipment. Maintain your water pH between 7.4 and 7.8 and total alkalinity between 100 and 150 p.p.m. If the mineral content and dissolved solids in the water become too high, scale forms inside the heat exchanger tubes, reducing heater efficiency and also damaging the heater (max TDS at 3000 ppm). If the pH drops below 7.2, the heater will be severely damaged.

*Loop is secondary piping to heater from main system

Table G: Flow Rates

NOTE: Heat exchanger damage resulting from chemical imbalance is not covered under the warranty.

19

Image 19
Contents Advanced Design Boiler Page Contents Pay Attention to These Terms Model Identification Before InstallationInstallations at Elevation Product ReceiptComponent Locations Component LocationsTime/Temperature Relationships in Scalds General SafetyEquipment Base InstallationInstallation Codes Indoor InstallationsDirect Vent Outdoor InstallationsCombustion and Ventilation Air Indoor UnitsInstallations1 Canadian Installations2 Canadian Installations InstallationsConventional Combustion Air Supply General Low Temperature SystemTemperature & Pressure Gauge Water PipingHydronic Heating Single Boiler Primary/Secondary Piping Dual Boiler Piping Domestic HOT Water Piping Single Boiler Domestic Hot Water with One Storage Tank Page Pool and Spa Water Chemistry Pool HeatingAutomatic Chlorinators and Chemical Feeders Winterizing Your HeaterSingle Boiler Pool Application Double Boiler Pool Application GAS Supply ConnectionsGas Supply Pressure Gas Supply ConnectionElectrical Power Connections Electrical Connections Domestic Hot Water Field Wiring ConnectionsGeneral Definition of Appliance Categories Venting ConnectionsVent Terminal Location Venting Configurations Venting Installation TipsADB-1501 Natural Draft Vertical Vent Termination Natural Draft Vertical Venting System InstallationADB-1501 Horizontal Thru-Wall Direct Venting/Combustion Air Category Horizontal Thru-wall Direct Vent TerminationÁDB-1501 Vertical Direct Venting/Combustion Air Category Vertical Direct Vent Termination Vertical Direct Venting System InstallationContact the manufacturer for details Horizontal Thru-wall Venting System Category IV Installation PVC, ABS Page Galvanized ADB-751 Venting Material e.g Subtract 10 ft per Condensate Trap Alignment Condensate DrainControls Central Point Wiring CPWCPW Board Blower Fan Post-purge Pump Turn-off DelayFreeze Protection Feature Blower Fan Pre-purgeLight Color Indication Diagnostics BoardFigure L-2 Wiring DiagramIgnition Control Module Flow SwitchHigh Limit Manual Reset High Limit Auto ResetFill the System High and Low Gas Pressure Switches Manual ResetPRE-START-UP Low Water Cut Off OptionalBlower T Fitting Detail Pre-Start-up CheckTools Needed ADB Initial START-UPPreparation for Start-up Page Follow-up Main Burner AdjustmentSafety Inspection Post START-UP CheckOperating Instructions MaintenanceSuggested Minimum Maintenance Schedule OperationMonthly Connecting the Condensing Heat Exchanger CHXCleaning Boiler Heating Surfaces DailyConnecting Add-on Condensing Heat Exchanger to ADB Vent Switch AdjustmentInside Combustion Air Contamination AppendixEmissions Settings and Test Information Bluff Head Body Burner Warranty

751 specifications

The Raypak 751 is a high-efficiency, gas-powered pool and spa heater renowned for its advanced technology and durability. Designed with innovative features, the Raypak 751 prioritizes user convenience and energy efficiency, making it an excellent choice for pool owners seeking reliable heating solutions.

One of the standout features of the Raypak 751 is its robust heat exchanger, built from the finest materials to ensure long-lasting performance. This model utilizes a copper heat exchanger which is highly conductive, allowing for rapid heating of water and maintenance of consistent temperatures. Its design also minimizes scale buildup, extending the longevity of the heater.

The Raypak 751 is equipped with advanced digital controls that make it user-friendly. The intuitive interface allows for precise temperature settings and monitoring, ensuring optimal performance. Additionally, the heater features a temperature display that provides real-time updates, giving users peace of mind when adjusting their pool's environment.

Energy efficiency is a hallmark of the Raypak 751, thanks to its low NOx burner technology. This feature meets stringent environmental regulations while also lowering operational costs. By optimizing fuel usage, the heater not only contributes to reducing greenhouse gas emissions but also provides a more economical heating option for pool and spa owners.

The rugged construction of the Raypak 751 is another characteristic that sets it apart. Its heavy-duty cabinet is designed to withstand the elements, ensuring reliable operation in various weather conditions. The heater is available in multiple configurations, including both natural gas and propane options, allowing for flexible installation depending on the user's needs.

Furthermore, the Raypak 751 incorporates safety features, such as an integrated pressure switch that prevents operation when water flow is insufficient. This protects both the heater and associated plumbing from damage due to overheating or dry firing.

In summary, the Raypak 751 combines cutting-edge technology with user-centric features to deliver a superior pool heating experience. Its high-efficiency performance, durable construction, and advanced safety features make it a top choice for anyone looking to enhance their pool or spa. Whether for residential or commercial applications, the Raypak 751 ensures warmth and comfort, enriching the overall swimming experience.