Raypak 751 manual Pay Attention to These Terms

Page 4

WARNINGS

Pay Attention to These Terms

DANGER:

Indicates the presence of immediate hazards which will cause severe

 

personal injury, death or substantial property damage if ignored.

 

 

WARNING:

Indicates the presence of hazards or unsafe practices which could cause

 

severe personal injury, death or substantial property damage if ignored.

 

 

CAUTION:

Indicates the presence of hazards or unsafe practices which could cause

 

minor personal injury or product or property damage if ignored.

 

 

NOTE:

Indicates special instructions on installation, operation, or maintenance which

are important but not related to personal injury hazards.

 

 

 

DANGER: Make sure the gas on which the heater will operate is the same type as that specified on the heater rating plate.

WARNING: Should overheating occur or the gas supply valve fail to shut, do not turn off or disconnect the electrical supply to the heater. Instead, shut off the gas supply at a location external to the heater.

WARNING: Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

WARNING: To minimize the possibility of improper operation, serious personal injury, fire, or damage to the heater:

Always keep the area around the heater free of combustible materials, gasoline, and other flammable liquids and vapors.

Heater should never be covered or have any blockage to the flow of fresh air to the heater.

WARNING: Risk of electrical shock. More than one disconnect switch may be required to de-energize the equipment before servicing.

WARNING - CALIFORNIA PROPOSITION

65:This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

CAUTION: Operation of this heater in low temperature systems requires special piping to ensure correct operation.

CAUTION: If this heater is to be installed above radiation level, it must be provided with a low water cut-off device at the time of heater installation.

CAUTION: This heater requires forced water circulation when the burner is operating. See minimum and maximum flow rates. Severe damage will occur if the heater is operated without proper water flow circulation.

4

Image 4
Contents Advanced Design Boiler Page Contents Pay Attention to These Terms Before Installation Installations at ElevationProduct Receipt Model IdentificationComponent Locations Component LocationsGeneral Safety Time/Temperature Relationships in ScaldsInstallation Installation CodesIndoor Installations Equipment BaseOutdoor Installations Combustion and Ventilation AirIndoor Units Direct VentInstallations1 Canadian Installations2 Canadian Installations InstallationsConventional Combustion Air Supply Low Temperature System Temperature & Pressure GaugeWater Piping GeneralHydronic Heating Single Boiler Primary/Secondary Piping Dual Boiler Piping Domestic HOT Water Piping Single Boiler Domestic Hot Water with One Storage Tank Page Pool Heating Automatic Chlorinators and Chemical FeedersWinterizing Your Heater Pool and Spa Water ChemistrySingle Boiler Pool Application GAS Supply Connections Double Boiler Pool ApplicationGas Supply Connection Gas Supply PressureElectrical Power Connections Field Wiring Connections Electrical Connections Domestic Hot WaterVenting Connections General Definition of Appliance CategoriesVent Terminal Location Venting Installation Tips Venting ConfigurationsADB-1501 Natural Draft Vertical Venting System Installation Natural Draft Vertical Vent TerminationADB-1501 Horizontal Thru-wall Direct Vent Termination Horizontal Thru-Wall Direct Venting/Combustion Air CategoryÁDB-1501 Vertical Direct Venting/Combustion Air Category Vertical Direct Venting System Installation Vertical Direct Vent TerminationContact the manufacturer for details Horizontal Thru-wall Venting System Category IV Installation PVC, ABS Page Galvanized ADB-751 Venting Material e.g Subtract 10 ft per Condensate Drain Condensate Trap AlignmentControls Central Point Wiring CPWCPW Board Pump Turn-off Delay Freeze Protection FeatureBlower Fan Pre-purge Blower Fan Post-purgeDiagnostics Board Light Color IndicationWiring Diagram Figure L-2Flow Switch High Limit Manual ResetHigh Limit Auto Reset Ignition Control ModuleHigh and Low Gas Pressure Switches Manual Reset PRE-START-UPLow Water Cut Off Optional Fill the SystemPre-Start-up Check Blower T Fitting DetailTools Needed ADB Initial START-UPPreparation for Start-up Page Main Burner Adjustment Safety InspectionPost START-UP Check Follow-upMaintenance Suggested Minimum Maintenance ScheduleOperation Operating InstructionsConnecting the Condensing Heat Exchanger CHX Cleaning Boiler Heating SurfacesDaily MonthlyVent Switch Adjustment Connecting Add-on Condensing Heat Exchanger to ADBAppendix Inside Combustion Air ContaminationEmissions Settings and Test Information Bluff Head Body Burner Warranty

751 specifications

The Raypak 751 is a high-efficiency, gas-powered pool and spa heater renowned for its advanced technology and durability. Designed with innovative features, the Raypak 751 prioritizes user convenience and energy efficiency, making it an excellent choice for pool owners seeking reliable heating solutions.

One of the standout features of the Raypak 751 is its robust heat exchanger, built from the finest materials to ensure long-lasting performance. This model utilizes a copper heat exchanger which is highly conductive, allowing for rapid heating of water and maintenance of consistent temperatures. Its design also minimizes scale buildup, extending the longevity of the heater.

The Raypak 751 is equipped with advanced digital controls that make it user-friendly. The intuitive interface allows for precise temperature settings and monitoring, ensuring optimal performance. Additionally, the heater features a temperature display that provides real-time updates, giving users peace of mind when adjusting their pool's environment.

Energy efficiency is a hallmark of the Raypak 751, thanks to its low NOx burner technology. This feature meets stringent environmental regulations while also lowering operational costs. By optimizing fuel usage, the heater not only contributes to reducing greenhouse gas emissions but also provides a more economical heating option for pool and spa owners.

The rugged construction of the Raypak 751 is another characteristic that sets it apart. Its heavy-duty cabinet is designed to withstand the elements, ensuring reliable operation in various weather conditions. The heater is available in multiple configurations, including both natural gas and propane options, allowing for flexible installation depending on the user's needs.

Furthermore, the Raypak 751 incorporates safety features, such as an integrated pressure switch that prevents operation when water flow is insufficient. This protects both the heater and associated plumbing from damage due to overheating or dry firing.

In summary, the Raypak 751 combines cutting-edge technology with user-centric features to deliver a superior pool heating experience. Its high-efficiency performance, durable construction, and advanced safety features make it a top choice for anyone looking to enhance their pool or spa. Whether for residential or commercial applications, the Raypak 751 ensures warmth and comfort, enriching the overall swimming experience.