Raypak 751 manual Bluff Head Body Burner Warranty

Page 56

LIMITED PARTS WARRANTY

ADVANCED DESIGN BOILER™

SCOPE:

Raypak, Inc. ("Raypak") warrants to the original owner that all parts of this boiler which are actually manufactured by Raypak will be free from failure under normal use and service for the specified warranty periods and subject to the conditions set forth in this Warranty. Labor charges and other costs for parts removal or reinstallation, shipping and transportation are not cov- ered by this Warranty but are the owner's responsibility.

HEAT EXCHANGER WARRANTY:

°Ten (10) Years from date of boiler installation. This includes only cupro-nickel with bronze or cast iron waterways.

°Twenty (20) Years from date of boiler installation against "Thermal Shock" (excluded, however, if caused by boiler opera- tion at large changes exceeding 150°F between the water temperature at intake and boiler temperature, or operating at boiler temperatures exceeding 230°F).

BLUFF HEAD BODY BURNER WARRANTY:

°Ten (10) Years from date of boiler installation.

ANY OTHER PART MANUFACTURED BY RAYPAK:

One (1) Year warranty from date of boiler installation, or eighteen (18) months from date of factory shipment based on Raypak's records, whichever comes first.

SATISFACTORY PROOF OF INSTALLATION DATE, SUCH AS INSTALLER INVOICE, IS REQUIRED. THIS WARRANTY WILL BE VOID IF THE BOILER RATING PLATE IS ALTERED OR REMOVED.

ADDITIONAL WARRANTY EXCLUSIONS:

This warranty does not cover failures or malfunctions resulting from:

1.Failure to properly install, operate or maintain the boiler in accordance with our printed instructions provided;

2.Abuse, alteration, accident, fire, flood and the like;

3.Sediment or lime buildup, freezing, or other conditions causing inadequate water circulation;

4.High velocity flow exceeding boiler design rates;

5.Failure of connected systems devices, such as pump or controller;

6.Use of non-factory authorized accessories or other components in conjunction with the boiler system;

7.Failing to eliminate air from, or replenish water in, the connected water system;

8.Chemical, particulate matter or other airborne contamination of combustion air or use of chemical additives to water.

PARTS REPLACEMENT:

Under this Warranty, Raypak will furnish a replacement for any failed part. The failed part must first be returned to Raypak if requested, with transportation charges prepaid, and all applicable warranty conditions found satisfied. The replacement part will be warranted for only the unexpired portion of the original warranty. Raypak makes no warranty whatsoever on parts not manufactured by it, but Raypak will apply any such warranty as may be provided to it by the parts manufacturer.

TO MAKE WARRANTY CLAIM:

Promptly notify the original installer, supplying the model and serial numbers of the unit, date of installation and description of the problem. The installer must then notify his Raypak distributor for instructions regarding the claim. If either is not avail- able, contact Service Manager, Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 or call (805) 278-5300. In all cases proper authorization must first be received from Raypak before replacement of any part.

EXCLUSIVE WARRANTY - LIMITATION OF LIABILITY:

This is the only warranty given by Raypak. No one is authorized to make any other warranties on Raypak's behalf. THIS WARRANTY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. RAYPAK'S SOLE LIA- BILITY AND THE SOLE REMEDY AGAINST RAYPAK WITH RESPECT TO DEFECTIVE PARTS SHALL BE AS PROVIDED IN THIS WARRANTY. IT IS AGREED THAT RAYPAK SHALL HAVE NO LIABILITY, WHETHER UNDER THIS WARRANTY, OR IN CONTRACT, TORT, NEGLIGENCE OR OTHERWISE, FOR ANY SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGE, INCLUDING DAMAGE FROM WATER LEAKAGE. Some states do not allow limitations on how long an implied warranty lasts, or for the exclusion of incidental or consequential damages. So the above limitation or exclusion may not apply to you.

This Limited Warranty gives you specific legal rights. You may also have other rights which may vary from state to state. We suggest that you complete the information below and retain this certificate in the event warranty service is needed. Reasonable proof of the effective date of the warranty (date of installation) must be presented, otherwise, the effective date will be based on the date of manufacture plus thirty (30) days.

56

Image 56
Contents Advanced Design Boiler Page Contents Pay Attention to These Terms Before Installation Installations at ElevationProduct Receipt Model IdentificationComponent Locations Component LocationsGeneral Safety Time/Temperature Relationships in ScaldsInstallation Installation CodesIndoor Installations Equipment BaseOutdoor Installations Combustion and Ventilation AirIndoor Units Direct VentInstallations1 Canadian Installations2 Conventional Combustion Air Supply InstallationsCanadian Installations Low Temperature System Temperature & Pressure GaugeWater Piping GeneralHydronic Heating Single Boiler Primary/Secondary Piping Dual Boiler Piping Domestic HOT Water Piping Single Boiler Domestic Hot Water with One Storage Tank Page Pool Heating Automatic Chlorinators and Chemical FeedersWinterizing Your Heater Pool and Spa Water ChemistrySingle Boiler Pool Application GAS Supply Connections Double Boiler Pool ApplicationGas Supply Connection Gas Supply PressureElectrical Power Connections Field Wiring Connections Electrical Connections Domestic Hot WaterVenting Connections General Definition of Appliance CategoriesVent Terminal Location Venting Installation Tips Venting ConfigurationsADB-1501 Natural Draft Vertical Venting System Installation Natural Draft Vertical Vent TerminationADB-1501 Horizontal Thru-wall Direct Vent Termination Horizontal Thru-Wall Direct Venting/Combustion Air CategoryÁDB-1501 Vertical Direct Venting/Combustion Air Category Vertical Direct Venting System Installation Vertical Direct Vent TerminationContact the manufacturer for details Horizontal Thru-wall Venting System Category IV Installation PVC, ABS Page Galvanized ADB-751 Venting Material e.g Subtract 10 ft per Condensate Drain Condensate Trap AlignmentCPW Board Central Point Wiring CPWControls Pump Turn-off Delay Freeze Protection FeatureBlower Fan Pre-purge Blower Fan Post-purgeDiagnostics Board Light Color IndicationWiring Diagram Figure L-2Flow Switch High Limit Manual ResetHigh Limit Auto Reset Ignition Control ModuleHigh and Low Gas Pressure Switches Manual Reset PRE-START-UPLow Water Cut Off Optional Fill the SystemPre-Start-up Check Blower T Fitting DetailPreparation for Start-up ADB Initial START-UPTools Needed Page Main Burner Adjustment Safety InspectionPost START-UP Check Follow-upMaintenance Suggested Minimum Maintenance ScheduleOperation Operating InstructionsConnecting the Condensing Heat Exchanger CHX Cleaning Boiler Heating SurfacesDaily MonthlyVent Switch Adjustment Connecting Add-on Condensing Heat Exchanger to ADBAppendix Inside Combustion Air ContaminationEmissions Settings and Test Information Bluff Head Body Burner Warranty

751 specifications

The Raypak 751 is a high-efficiency, gas-powered pool and spa heater renowned for its advanced technology and durability. Designed with innovative features, the Raypak 751 prioritizes user convenience and energy efficiency, making it an excellent choice for pool owners seeking reliable heating solutions.

One of the standout features of the Raypak 751 is its robust heat exchanger, built from the finest materials to ensure long-lasting performance. This model utilizes a copper heat exchanger which is highly conductive, allowing for rapid heating of water and maintenance of consistent temperatures. Its design also minimizes scale buildup, extending the longevity of the heater.

The Raypak 751 is equipped with advanced digital controls that make it user-friendly. The intuitive interface allows for precise temperature settings and monitoring, ensuring optimal performance. Additionally, the heater features a temperature display that provides real-time updates, giving users peace of mind when adjusting their pool's environment.

Energy efficiency is a hallmark of the Raypak 751, thanks to its low NOx burner technology. This feature meets stringent environmental regulations while also lowering operational costs. By optimizing fuel usage, the heater not only contributes to reducing greenhouse gas emissions but also provides a more economical heating option for pool and spa owners.

The rugged construction of the Raypak 751 is another characteristic that sets it apart. Its heavy-duty cabinet is designed to withstand the elements, ensuring reliable operation in various weather conditions. The heater is available in multiple configurations, including both natural gas and propane options, allowing for flexible installation depending on the user's needs.

Furthermore, the Raypak 751 incorporates safety features, such as an integrated pressure switch that prevents operation when water flow is insufficient. This protects both the heater and associated plumbing from damage due to overheating or dry firing.

In summary, the Raypak 751 combines cutting-edge technology with user-centric features to deliver a superior pool heating experience. Its high-efficiency performance, durable construction, and advanced safety features make it a top choice for anyone looking to enhance their pool or spa. Whether for residential or commercial applications, the Raypak 751 ensures warmth and comfort, enriching the overall swimming experience.