Page 3

GENERAL SAFETY

To meet commercial hot water use needs, the high limit safety control on this water heater is adjustable up to 210°F. However, water temperatures over 125°F can cause instant severe burns or death from scalds. When supplying general purpose hot water, the rec- ommended initial setting for the temperature control is 125°F.

Safety and energy conservation are factors to be con- sidered when setting the water temperature on the thermostat. The most energy-efficient operation will result when the temperature setting is the lowest that satisfies the needs of the application.

Water temperature over 125°F can cause instant severe burns or death from scalds. Children, disabled and elderly are at highest risk of being scalded.

Feel water before bathing or showering.

Temperature limiting valves are available.

NOTE: When this water heater is supplying general purpose hot water for use by individuals, a thermo- statically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of scald injury. Contact a licensed plumber or the local plumbing authority for further information.

Maximum water temperatures occur just after the heater’s burner has shut off. To determine the water temperature being delivered, turn on a hot water faucet and place a thermometer in the hot water stream and read the thermometer.

Water temperature over 125°F can cause instant severe burns or death from scalds.

Children, disabled, and elderly are at highest risk of being scalded.

See instruction manual before set- ting temperature at water heater.

Feel water before bathing or show- ering.

Temperature limiting valves are available, see manual.

Time/Temperature

Relationships in Scalds

The following chart details the relationship of water temperature and time with regard to scald injury and may be used as a guide in determining the safest water temperature for your applications.

Water

Time to Produce

Temp.

Serious Burn

 

 

120°F

More than 5 minutes

 

 

125°F

1-1/2 to 2 minutes

 

 

130°F

About 30 seconds

 

 

135°F

About 10 seconds

 

 

140°F

Less than 5 seconds

 

 

145°F

Less than 3 seconds

 

 

150°F

About 1-1/2 seconds

 

 

155°F

About 1 second

 

 

Table courtesy of The Shriners Burn Institute

Table A: Time to Produce Serious Burn

3

Image 3
Contents Installation and Operating Instructions Page Time/Temperature Relationships in Scalds General SafetyCold Water Start InstallationOperation Connecting Power to the ControllerCold Start Sequence Operation Mode Selection SwitchElodrive Actuator Rotation Knob Setting TroubleshootingCold Water Start Troubleshooting Guide Wiring Diagram Cold Water RUN Model Pump Injection & Heater Pump Comparison Hi DeltaBefore Starting Injection Pump Cover InstallationPlace the cover on the pump Typical Boiler Piping Hi Delta shown Sequence of Operation START-UP ProcedureWiring Diagram Step Cold Water Run Troubleshooting GuideCold Water Start Illustrated Parts ListsCall OUT Description HI Delta MVB Cold Water Run Call Description HI Delta MVB OUT