Raypak 1000, 500 Section M General Safety Precautions, TIME/TEMPERATURE Relationships in Scalds

Page 56

SECTION M: GENERAL SAFETY PRECAUTIONS

To meet commercial water use needs, an external operating control for this hot water boiler is adjustable up to 210°F. However, water temperatures over 125°F can cause instant severe burns or death from scalds. The preferred starting point for setting the control for supplying general purpose hot water is 125°F.

Safety and energy conservation are factors to be considered when setting the water temperature on the thermostat. The most energy efficient operation will result when the temperature setting is the lowest that satisfies the needs consistent with the application.

Water temperature over 125°F can cause severe burns instantly or death from scalds.

Children, disabled and elderly are at highest risk of being scalded.

See instruction manual before setting temperature at water heater.

Feel water before bathing or showering.

Temperature limiting valves are available, see note below.

Maximum water temperatures occur just after the boiler’s burner has shut off. To determine the water temperature being delivered, turn on a hot water faucet and place a thermometer in the hot water stream.

The following chart details the relationship of water temperature and time with regard to scald injury and may be used as a guide in determining the safest water temperature for your applications.

Temperature

Time to Produce Serious Burn

Temperature

Time to Produce Serious Burn

120°F.

More than 5 minutes

140°F.

Less than 5 seconds

125°F.

1-1/2 to 2 minutes

145°F.

Less than 3 seconds

130°F.

About 30 seconds

150°F.

About 1-1/2 seconds

135°F.

About 10 seconds

155°F.

About 1 second

Table courtesy of The Shriners Burn Institute

TIME/TEMPERATURE RELATIONSHIPS IN SCALDS

The temperature of the water in the hot water boiler can be regulated by setting the temperature dial on front of the thermostat. To comply with safety regulations the thermostat was set at its lowest setting before the hot water boiler was shipped from the factory. The illustration below shows the thermostat and how to adjust the water temperature.

To adjust the water temperature, insert a small straight screwdriver into slotted screw in hole in front of thermostat and turn wheel to desired setting.

CAUTION!! - Hotter water Increases the risk of SCALDING!

Adjustment

Screw

There is a Hot Water SCALD Potential if the tank thermostat is set too high.

NOTE: When this hot water boiler is supplying general purpose hot water requirements for use by individuals, a thermo- statically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of scald injury. Contact a licensed plumber or the local plumbing authority for further information.

56

Image 56
Contents For Your Safety For Your Safety What to do if YOU Smell GASPage Table of Contents Section a Before Installing the Boiler Product ReceiptModelidentification Ratings and CertificationFigure A-1 Advanced Design Boiler Component LocationsEquipment Base Section B Boiler InstallationInstallation Codes Figure B-1 Outdoor Installation Minimum Clearances Section C Combustion and Ventilation AIR Direct Combustion AIRPage LOW Temperature System Temperature & Pressure GaugeSection D Water Piping General Reliefvalve PipingSection E Hydronic Heating Piping Pump SelectionPressure Drop in Feet of Head Feedwater Regulator Piping Heating BoilersAIR-SEPARATION/EXPANSION Tank THREE-WAY ValvesSingle Boiler PRIMARY/SECONDARY Piping with CHX DUAL-BOILER PRIMARY/SECONDARY PipingFigure E-3b Dual Boiler -PRIMARY/SECONDARY Piping with CHXSection F Domestic HOT Water Piping Single Boiler Domestic HOT Water with ONE Storage TankFigure F-1c Winterizingyour Heater Section G Pool HeatingAutomatic Chlorinators and Chemical Feeders Single Boiler Pool Application with CHX Spawater ChemistrySingle Boiler Pool Application Figure G-3a Double Boiler Pool ApplicationGAS Supply Pressure Section H GAS Supply ConnectionsGAS Supply Connection Venting of Diaphragm GAS Components Regulator Pressure SettingsGAS Pressure Regulator Section I Electrical Power Connections Check the Power SourceCheck Power Source Surge ProtectionField Wiring Connection Making the Electrical ConnectionsElectrical Connections Domestic HOT Water Section J Venting Connections GeneralPage Support of Vent Stack Venting Configurations Figure J-1 Natural Draft Vertical Vent Termination Page Section J-2 Heat Exchanger CategoryPage Section J-3 CategoryPage Section J-4 Vertical Direct Venting/Combustion Air CategoryVertical Direct Venting System Installation Figure J-5 Page Section J-6 Figure J-6Horizontal Thru-wall Venting System Category IV Installation Figure J-7 Page Figure J-8 Page Outdoor Installation withAdd-On Condensing Heat Exchanger Section K Condensate Drain Condensate Trap AlignmentCPW Board Central Point Wiring CPWSection L Controls Figure L-1 CPW Board Pump Turn-off Delay Manual High Limit Red Wiring Diagram Figure L-2High Limit Manual Reset Manual Reset High Limit Flow SwitchFlow Switch High Limit Auto Reset Auto Reset High LimitPressure Control Device ACU-TRACK GAS Pressure SwitchLOW Water CUT OFF Optional Section M General Safety Precautions TIME/TEMPERATURE Relationships in ScaldsSection N PRE-START-UP Figure O-1 Component and Pressure TAP LocationsPreparation for START-UP Do not Turn on GAS AT this Time Section O ADB Initial START-UPTools Needed START-UP Page CO2 Section P Post START-UP CheckEmissions Guidelines To Turn OFF GAS to Appliance Section Q OperationOperating Instructions Section R Maintenance Suggested Minimum Maintenance ScheduleCleaning Boiler Heating Surfaces Section S Connecting Condensing Heat Exchanger CHX Vent Switch AdjustmentAppendix a InsidecombustionaircontaminationPage Page Page Page Page START-UP Settings Pressure SettingsLitho in U. S. a
Related manuals
Manual 8 pages 63.38 Kb Manual 8 pages 12.19 Kb

1000, 750, 500 specifications

Raypak is a renowned name in the heating industry, particularly known for its high-quality pool and spa heaters. Among their extensive product line, the Raypak 850, 500, 300, 400, and 700 models stand out for their reliability, efficiency, and cutting-edge technologies. Each model is designed to cater to different needs and applications while maintaining Raypak’s commitment to performance.

The Raypak 850 is designed for larger commercial pools or residential setups requiring high output. With a powerful heat exchanger made from copper and bronze, it ensures superior heat transfer and longevity. Its digital control system provides precise temperature regulation, enhancing user experience. Moreover, it features a durable construction with weather-resistant materials, ensuring lasting performance in various environments.

The Raypak 500 model offers a balance between efficiency and compactness. It features eco-friendly technology that reduces energy consumption without sacrificing performance. The integrated thermostat allows users to maintain consistent water temperatures, making it ideal for residential pools. This model is well-regarded for its user-friendly digital display, simplifying operation and monitoring.

For those needing a more moderate capacity, the Raypak 300 is an efficient choice. It combines robust engineering with an easy-to-use interface. Its advanced ignition system improves reliability while minimizing energy waste. The Raypak 300’s compact design allows for easy installation in various spaces, making it an excellent option for smaller pools.

The Raypak 400 heats water quickly and efficiently, making it suitable for both residential pools and spas. It features a high-capacity heating system that ensures optimal performance. With a clear LED display, users can easily monitor their settings, while the integrated diagnostics provide real-time feedback for maintenance and troubleshooting.

Lastly, the Raypak 700 model is known for its versatility and robust performance. It is equipped with advanced safety features, including a high limit switch and water flow detection mechanism, to ensure safe operation. The model's energy-efficient design enhances its eco-friendliness, making it a popular choice among environmentally conscious users.

Collectively, these Raypak models exemplify superior engineering, performance, and user-friendliness. Their innovative features ensure that they meet the varied demands of pool owners while providing reliable heating solutions for leisure and relaxation. Whether for commercial or residential use, the Raypak 850, 500, 300, 400, and 700 offer unmatched quality and efficiency.