Pentair MiniMax NT LN installation manual GAS Pipe Sizing, Pipe Sizing for GAS Line Connections

Page 12

Section III. Installation

12

 

 

GAS PIPE SIZING

Table 2.

PIPE SIZING FOR GAS LINE CONNECTIONS

MAXIMUM EQUIVALENT PIPE LENGTH (Ft.)

Natural Gas at 1000 B.T.U. per Cubic Foot

 

 

1/2”

3/4”

1”

1-1/4”

1-1/2”

2”

2-1/2”

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

NAT

NAT

NAT

NAT

NAT

NAT

NAT

 

 

 

 

 

 

 

 

 

 

 

 

200

-

30’

125’

450’

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

250

-

20’

70’

250’

600’

-

-

 

 

 

 

 

 

 

 

 

 

 

 

300

-

10’

50’

200’

400’

-

-

 

 

 

 

 

 

 

 

 

 

 

 

400

-

-

20’

100’

200’

400’

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“RESIDENTIAL” NATURAL GAS 2 STAGE REGULATION

In many Natural gas line installations, the gas supplier and/or installer may utilize a two stage regulation process where by at the streets main gas supply they will install the first stage gas regulator, which would be at a higher pressure. This higher pressure is usually set at 2 psi or 5 psi and can be for long distances and in a much smaller pipe size. Then within a short distance of the pool heater, generally around

24 inches, they will install a second regulator, which is the second stage. This second stage regulator would be set at the minimum operating pressure for the heater. For “Natural Gas Pentair Pool Heaters” the minimum is 7 inches W.C.

See “Gas Pressure Requirement Charts”

Stage One "High Pressure" Gas Pipe Sizing

2 PSI @ 1000 B.T.U. Per CU. FT.

MAXIMUM EQUIVALENT PIPE LENGTH

 

Model

0 to 50 Ft.

50 to 100

Ft.

100 to 150 Ft.

 

 

 

 

 

 

 

 

200

through 300

1/2

in.

1/2

in.

 

1/2 in.

 

 

 

 

 

 

 

400

3/4 in.

3/4 in.

 

3/4 in.

 

 

 

 

 

 

5 PSI @ 1000 B.T.U. Per CU. FT.

 

 

 

 

 

 

 

 

200

through 400

1/2

in.

1/2

in.

 

1/2 in.

 

 

 

 

 

 

 

 

Table 3.

Stage Two "Low Pressure" Gas Pipe Sizing

Stage 2 set at 7 in. W.C.

MAXIMUM EQUIVALENT PIPE LENGTH

Model

0 to 10 Ft.

10 to 20 Ft.

 

 

 

200 through 300

3/4 in.

3/4 in.

 

 

 

400

3/4 in.

1 in.

 

 

 

Stage 2 set at 7 in. W.C.

200 through 400

3/4 in.

1 in.

 

 

 

Table 4.

P/N 472089

Rev. E 4-19-05

Image 12
Contents MiniMax NT LN Series Customer Service Table of Contents Heater Identification Information Heater Identification Information HINWarranty Information Important NoticesConsumer Information and Safety Code RequirementsInstallation Instructions SpecificationsBelow Pool Installation Below or Above Pool InstallationPlumbing Connections ValvesWater Connections Reversing HeadersReversible Inlet/Outlet Connection, cont’d GAS Line Installations GAS ConnectionsSediment Traps GAS Pipe Sizing Pipe Sizing for GAS Line ConnectionsTesting GAS Pressure GAS Pressure RequirementsIndoor Venting General Requirements Indoor Installation USA only Outdoor Shelter Installation CanadaCombustion AIR Supply Vent AdaptorsFits ALL Models Indoor Installations Minimax NT Venting Guidelines Outdoor Installation Venting Guidelines Side View Outdoor Vent KITElectrical Rating 60 Hz 120 / 240 Volts AC, single phase Electrical ConnectionsWire Color Basic System Operation Minimax NT LN HSI Electronic Ignition LIGHTING/OPERATIONSafety Controls Vacuum AIR Pressure FAN SwitchWater Pressure Switch LOW GAS Pressure SwitchHeat Mode High LimitsOperation of Ignition Module Failure to Light the BURNER-LOCK OUTDigital Display Temperature Controller Ddtc System Indicator LightsSection IV. Operation SET UP Temperature Setting Troubleshooting Instruction Troubleshooting DdtcTroubleshooting General Service CHECKS-IGNITION ModuleMaintenance Instruction Energy Saving TipsSpring and Fall Operation Winter OperationChemical Balance Pool and SPA WaterReplacement Parts NT LN w/DDTC Rev. E Rev. E Pentair Water Pool and Spa, Inc