Pentair MiniMax NT LN Digital Display Temperature Controller Ddtc, System Indicator Lights

Page 24

Section IV. Operation

24

 

 

DIGITAL DISPLAY TEMPERATURE CONTROLLER (DDTC)

SYSTEM INDICATOR LIGHTS

POWER

REMOTE

 

PRESSURE SW

POOL

 

 

SPA

THERMOSTAT

 

 

 

OFF

HEATING

TEMPERATURE

SETTING

SERVICE

POOL

SPA

 

PRESS ANY ARROW ONCE TO

 

CHECK SET TEMPERATURE

Figure 26.

REMOTE BUTTON

POOL BUTTON

SPA BUTTON

OFF BUTTON

TEMP. UP

SPA AND POOL TEMPERATURE SET BUTTONS

TEMP. DOWN

The DDTC board, shown in Figure 26, is a digital temperature controller capable of controlling the pool, spa or both to a minimum temperature of 65° F. (below 65° F. display reads "Off") and a maximum of 104° F. The DDTC board also functions as a system status indicator, using LED lights and programmed error codes.

During normal operation, the DDTC will display the current temperature of the water returning to the heater, depending on which mode has been selected, “Pool” or “Spa”. This is accomplished by a thermister (sensor) on the inlet port of the water header of the heater and working in conjunction with the internal microprocessor controlling the operation of the heater.

Changing the desired pool or spa temperature is easily done by simply depressing the appropriate up or down arrow until the display reads the desired set-point temperature. For example, set pool to 78° F. and the spa to 104° F., when releasing the up or down arrow the display will flash once then return to the current temperature.

At any time, you wish to know the temperature setting of the pool or spa, simply press the appropriate up or down arrow, the display will flash once and display the set-point temperature for three (3) seconds, then flash once again and return to the current temperature.

P/N 472089

Rev. E 4-19-05

Image 24
Contents MiniMax NT LN Series Customer Service Table of Contents Heater Identification Information Heater Identification Information HINWarranty Information Important NoticesConsumer Information and Safety Code RequirementsInstallation Instructions SpecificationsBelow Pool Installation Below or Above Pool InstallationPlumbing Connections ValvesWater Connections Reversing HeadersReversible Inlet/Outlet Connection, cont’d GAS Line Installations GAS ConnectionsSediment Traps GAS Pipe Sizing Pipe Sizing for GAS Line ConnectionsTesting GAS Pressure GAS Pressure RequirementsIndoor Venting General Requirements Indoor Installation USA only Outdoor Shelter Installation CanadaCombustion AIR Supply Vent AdaptorsFits ALL Models Indoor Installations Minimax NT Venting Guidelines Outdoor Installation Venting Guidelines Side View Outdoor Vent KITElectrical Rating 60 Hz 120 / 240 Volts AC, single phase Electrical ConnectionsWire Color Basic System Operation Minimax NT LN HSI Electronic Ignition LIGHTING/OPERATIONSafety Controls Vacuum AIR Pressure FAN SwitchWater Pressure Switch LOW GAS Pressure SwitchHeat Mode High LimitsOperation of Ignition Module Failure to Light the BURNER-LOCK OUTDigital Display Temperature Controller Ddtc System Indicator LightsSection IV. Operation SET UP Temperature Setting Troubleshooting Instruction Troubleshooting DdtcTroubleshooting General Service CHECKS-IGNITION ModuleMaintenance Instruction Energy Saving TipsSpring and Fall Operation Winter OperationChemical Balance Pool and SPA WaterReplacement Parts NT LN w/DDTC Rev. E Rev. E Pentair Water Pool and Spa, Inc