Section V. Troubleshooting

28

Troubleshooting Instruction

TROUBLESHOOTING (DDTC)

The DDTC temperature display contains three LED’s with a decimal point between the first and second, this display is also used to display an error code if for some reason there is a failure within the heater control system or a DDTC internal fault. The DDTC will display the actual temperature or set-point temperature or OFF, as selected by the user. When DDTC detects an error, the display will show Exx, see Figure 27, where Exx is the error code of DDTC fault, see Table 11. Codes 1 through 9 indicate a “soft lockout” error that means after these errors are fixed, the heater will resume normal operation and restart immediately. Code ERR indicates a “hard lockout” error that means after these errors are fixed, you need to reset the power of the heater through the switch on the bottom of the electrical junction box on the right side of the cabinet.

NOTE: If Code ERR is shown on the LED display at any time, turn the heater off, (from power switch), then turn on the heater again. If the error code is still displayed, call a certified Pentair Service Technician for repair.

Error Code

Error Description

 

 

E01

System Low Voltage

 

 

E02

High Temperature Limit

 

 

E03

Thermal Fuse Open

 

 

E04

Fan Failure

 

 

E05

Ignition / Flame Failure

 

 

E06

Gas Valve / Module Failure

 

 

E07, E08, E09

Not Used

 

 

ERR

Call Pentair's Technical Service Department at: (800) 831-7133

 

 

Table 11.

P/N 472089

Rev. E 4-19-05

Image 28
Contents MiniMax NT LN Series Customer Service Table of Contents Heater Identification Information Heater Identification Information HINWarranty Information Important NoticesConsumer Information and Safety Code RequirementsInstallation Instructions SpecificationsBelow Pool Installation Below or Above Pool InstallationPlumbing Connections ValvesWater Connections Reversing HeadersReversible Inlet/Outlet Connection, cont’d GAS Connections GAS Line InstallationsSediment Traps GAS Pipe Sizing Pipe Sizing for GAS Line ConnectionsTesting GAS Pressure GAS Pressure RequirementsIndoor Venting General Requirements Indoor Installation USA only Outdoor Shelter Installation CanadaVent Adaptors Combustion AIR SupplyFits ALL Models Indoor Installations Minimax NT Venting Guidelines Outdoor Installation Venting Guidelines Side View Outdoor Vent KITElectrical Rating 60 Hz 120 / 240 Volts AC, single phase Electrical ConnectionsWire Color Basic System Operation Minimax NT LN HSI Electronic Ignition LIGHTING/OPERATIONSafety Controls Vacuum AIR Pressure FAN SwitchWater Pressure Switch LOW GAS Pressure SwitchHeat Mode High LimitsOperation of Ignition Module Failure to Light the BURNER-LOCK OUTDigital Display Temperature Controller Ddtc System Indicator LightsSection IV. Operation SET UP Temperature Setting Troubleshooting Instruction Troubleshooting DdtcTroubleshooting General Service CHECKS-IGNITION ModuleMaintenance Instruction Energy Saving TipsSpring and Fall Operation Winter OperationChemical Balance Pool and SPA WaterReplacement Parts NT LN w/DDTC Rev. E Rev. E Pentair Water Pool and Spa, Inc