Pentair MiniMax NT LN installation manual Troubleshooting General, Service CHECKS-IGNITION Module

Page 29

Section V. Troubleshooting

29

 

 

TROUBLESHOOTING (GENERAL)

Possible Cause

Remedy

 

 

Heater will not come on

 

 

 

 

Check if electrical connections are

Automatic ignition system fails

correct and securely fastened –

 

If YES, call serviceperson.

Pump not running

Place pump in operation

Pump air locked

Check for leaks

Filter dirty

Clean filter

Pump strainer clogged

Clean strainer

Defective wiring or connection

Repair or replace wires

Defective pressure switch

Replace switch

Defective gas controls

Call serviceperson

On-Off switch in "OFF" position

Turn switch to "ON"

Heater Short Cycling (Rapid On and Off Operation)

 

 

Insufficient water flow

Clean filter and pump strainer

Defective wiring

Repair or replace wiring

Defective flow valve or out of adjustment

Call serviceperson

Defective hi-limit and/or thermostat

Call serviceperson

Heater Makes Knocking Noises,

make sure all valves on system are open.

Heater operating after pump has shut off

 

 

Shut off gas supply and call serviceperson

Heater exchanger scaled

 

 

Shut off gas supply and call serviceperson

 

 

 

 

 

SERVICE CHECKS—IGNITION MODULE

 

 

 

 

 

Symptom

Cause/Cure

 

 

 

 

 

 

 

1.

Dead

A. Miswired

 

 

 

 

B. Transformer bad

 

 

 

 

C.

Fuse/Circuit breaker bad

 

 

 

 

D.

Bad control

 

 

 

 

 

 

 

 

2.

Thermostat on—no ignition

A.

Miswired

 

 

 

 

B. Bad thermostat no voltage at terminal

 

 

 

 

 

 

 

 

3.

Valve on, no ignition

A.

Defective ignitor

 

 

 

 

B.

Miswired

 

 

 

 

C. Bad control (check voltage at ignitor)

 

 

 

 

 

 

 

 

4.

Ignitor on, no valve action

A.

Valve coil open

 

 

 

 

B. Open valve wire

 

 

 

 

C. Bad control (check voltage)

 

 

 

 

 

 

 

5.

Flame okay during

A. Bad flame sensor

 

 

 

Try For Ignition (TFI),

B.

Bad wires

 

 

 

no flame sense (after TFI)

C.

Poor ground at burner

 

 

 

 

D. Poor flame (check flame current)

 

 

 

 

 

 

 

 

Rev. E 4-19-05

P/N 472089

Image 29
Contents MiniMax NT LN Series Customer Service Table of Contents Heater Identification Information HIN Heater Identification InformationImportant Notices Warranty InformationCode Requirements Consumer Information and SafetySpecifications Installation InstructionsBelow or Above Pool Installation Below Pool InstallationPlumbing Connections ValvesReversing Headers Water ConnectionsReversible Inlet/Outlet Connection, cont’d Sediment Traps GAS Line InstallationsGAS Connections Pipe Sizing for GAS Line Connections GAS Pipe SizingGAS Pressure Requirements Testing GAS PressureIndoor Venting General Requirements Outdoor Shelter Installation Canada Indoor Installation USA onlyFits ALL Models Combustion AIR SupplyVent Adaptors Indoor Installations Minimax NT Venting Guidelines Outdoor Vent KIT Outdoor Installation Venting Guidelines Side ViewElectrical Connections Electrical Rating 60 Hz 120 / 240 Volts AC, single phaseWire Color Minimax NT LN HSI Electronic Ignition LIGHTING/OPERATION Basic System OperationVacuum AIR Pressure FAN Switch Safety ControlsWater Pressure Switch LOW GAS Pressure SwitchHigh Limits Heat ModeOperation of Ignition Module Failure to Light the BURNER-LOCK OUTSystem Indicator Lights Digital Display Temperature Controller DdtcSection IV. Operation SET UP Temperature Setting Troubleshooting Ddtc Troubleshooting InstructionService CHECKS-IGNITION Module Troubleshooting GeneralEnergy Saving Tips Maintenance InstructionWinter Operation Spring and Fall OperationPool and SPA Water Chemical BalanceReplacement Parts NT LN w/DDTC Rev. E Rev. E Pentair Water Pool and Spa, Inc