Samsung AS18A9(A0)RCD, US12AA(AB)MC, US12A5(A6)MC, US18A5(A6)RC Technical Specifications, Model

Page 24

Technical Specifications

 

 

MODEL

 

AS07A5(A6)MA

AS09A5(A6)MA

AS12A5(A6)MC

 

Performance

Capacity Cooling

Btu/h

7500

9000

11500

 

Ratings

 

 

 

 

 

 

 

SEER

 

10.0

10.0

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture Removal

Pts/h

2.5

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

Air FLOW(Cooling, HIGH)

CFM

214

230

261

 

 

 

 

 

 

 

 

 

 

 

 

Sound Rating-Outdoor

dB

50

51

53

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

Power source

 

115V~, 60Hz

115V~, 60Hz

208-230V~, 60Hz

 

Data

 

 

 

 

 

 

 

Min.Ampacity

A

6.4

8.5

6.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Watts

W

680

900

1320

 

 

 

 

 

 

 

 

 

 

 

Refrigeration

Connections

 

Flare

Flare

Flare

 

Lines

 

 

 

 

 

 

 

Liquid Line O. D.

mm(in)

6.35(1/4)

6.35(1/4)

6.35(1/4)

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction Line O.D.

mm(in)

9.52(3/8)

9.52(3/8)

12.70(1/2)

 

 

 

 

 

 

 

 

 

 

 

Factory Pre-charge

m(ft)

5.0 ( 1621 )

5.0 ( 1621 )

5.0 ( 1621 )

 

 

 

 

 

 

 

 

 

 

 

Max. Line length

m(ft)

15.0 ( 4941 )

15.0 ( 4941 )

15.0 ( 4941 )

 

 

 

 

 

 

 

 

 

 

 

Max. Height Difference

m(ft)

7.0(23)

7.0(23)

7.0(23)

 

 

 

 

 

 

 

 

 

 

Dimensions

INDOOR UNIT

 

AS07A5(A6)MA

AS09A5(A6)MA

AS12A5(A6)MC

 

& Weight

 

 

 

 

 

 

 

W X H X D

mm(in)

790 x 245 x 165

790 x 245 x 165

790 x 245 x 165

 

 

 

 

( 31 18 x 9 21 x 6 21 )

( 31 18 x 9 21 x 6 21 )

( 31 18 x 9 21 x 6 21 )

 

 

 

 

 

 

 

 

 

 

 

Net Weight

Ibs

21.2

21.2

21.2

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR UNIT

 

US07A5(A6)MA

US09A5(A6)MA

US12A5(A6)MC

 

 

 

 

 

 

 

 

 

 

 

W X H X D

mm(in)

660 x 497 x 235

660 x 497 x 235

762 x 532 x 280

 

 

 

 

( 26 x 19 12 x 9 41 ) ( 26 x 19 12 x 9 41 ) ( 30 x 20

7

x 11 )

 

 

 

 

8

Net Weight

 

Ibs

60.7

 

61.7

65.5

Standard rating conditions

Cooling

Indoor

Outdoor

 

 

 

 

 

 

DB

WB

DB

WB

 

 

°F

80

67

95

75

 

 

°C

26.7

19.4

35.0

23.9

 

E-24

Image 24
Contents Manuel D’UTILISATION & Manuel D’INSTALLATION Safety Precautions Contents View of the Unit Indoor UnitOutdoor Unit Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Installing the Remote Controller HolderUsing with the indoor unit Selecting with the Remote ControlWay Function To obtain anSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically Adjusting the Air Flow Direction HorizontallySetting the On Timer To Cancel the On TimerSetting the Off Timer To Cancel the Off TimerSetting the Sleep Timer To Cancel the Sleep TimerOperating Recommendations Topic RecommendationTemperature and Humidity Ranges Mode Outdoor Temperature Indoor Temperature Indoor HumidityIf the air conditioner is used at... Then Cleaning Your Air Conditioner Model AS07A5A6MA/AS09A5A6MA/AS12A5A6MC /AS12AAABMCSolving Common Problems AUTO, CoolInstalling a Filter Option Technical Specifications ModelAS18A5A6RC AS24A1A2RCInstallation Manual Purging the Unit Deciding on Where to Install the Air Conditioner Indoor Unit30mm1inch or more Air Conditioner and Accessories Accessories in the Indoor Unit CaseAccessories in the Outdoor Unit Case Fixing the Installation Plate Then follow StepsWall Window frame Connecting the Assembly Cable Purging the UnitAS18A9A0RCD / AS24A1A2RC Installing and Connecting the Indoor Unit Drain Hose To install the drain hose, proceed as followsInstalling and Connecting the Indoor Unit Assembly Piping PipeTorque Cutting/Extending the Piping Depth aConnecting the Cables to the Outdoor Unit 07/09AS12A5A6MC 18/24Auxiliary Circuit Breaker Electrical WorkChecking Correct Earthing 50 19Fixing the Unit in Position ModelConnecting Up and Purging the Circuit If you have used ThenTo check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics