Samsung US12AA(AB)MC, US12A5(A6)MC Deciding on Where to Install the Air Conditioner, Indoor Unit

Page 28

PREPARING THE INSTALLATION

Deciding on Where to Install the Air Conditioner

When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account.

General

Do NOT install the air conditioner in a location where it will come into contact with the following elements:

Combustible gases

Saline air

Machine oil

Sulphide gas

Special environmental conditions

If you must install the unit in such conditions, first consult your dealer.

Indoor Unit

There must be no obstacles near the air inlet and outlet.

Install the indoor unit on a surface that can support its weight.

Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the recommended length of 5m (16ft. 5in) to be respected (“L” m/ft. maximum).

Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance.

Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite.

Make sure that the water dripping from the drain hose runs away correctly and safely.

Outdoor Unit

The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the cooling circuit and seriously damage the unit.

Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.

Do not block any passageways or thoroughfares.

Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any neighbours.

Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended length of 5m (16ft. 5in) to be respected (“L” m/ft. maximum).

Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary noise and vibration.

Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.

Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite.

If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position; the maximum height is “H”m/ft. (“H”: indicated in the diagram on the page opposite.)

Make sure that the water dripping from the drain hose runs away correctly and safely.

CAUTION

You have just purchased a split-type room air conditioner and it has been installed by your installation specialist.

This device must be installed according to the national electrical rules.

E-28

Image 28
Contents Manuel D’UTILISATION & Manuel D’INSTALLATION Safety Precautions Contents View of the Unit Indoor UnitOutdoor Unit Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Installing the Remote Controller HolderUsing with the indoor unit Selecting with the Remote ControlWay Function To obtain anSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically Adjusting the Air Flow Direction HorizontallySetting the On Timer To Cancel the On TimerSetting the Off Timer To Cancel the Off TimerSetting the Sleep Timer To Cancel the Sleep TimerOperating Recommendations Topic RecommendationMode Outdoor Temperature Indoor Temperature Indoor Humidity Temperature and Humidity RangesIf the air conditioner is used at... Then Cleaning Your Air Conditioner Model AS07A5A6MA/AS09A5A6MA/AS12A5A6MC /AS12AAABMCSolving Common Problems AUTO, CoolInstalling a Filter Option Technical Specifications ModelAS18A5A6RC AS24A1A2RCInstallation Manual Purging the Unit Deciding on Where to Install the Air Conditioner Indoor Unit30mm1inch or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesAccessories in the Outdoor Unit Case Then follow Steps Fixing the Installation PlateWall Window frame Connecting the Assembly Cable Purging the UnitAS18A9A0RCD / AS24A1A2RC Installing and Connecting the Indoor Unit Drain Hose To install the drain hose, proceed as followsPipe Installing and Connecting the Indoor Unit Assembly PipingTorque Cutting/Extending the Piping Depth aConnecting the Cables to the Outdoor Unit 07/09AS12A5A6MC 18/24Auxiliary Circuit Breaker Electrical WorkChecking Correct Earthing 50 19Fixing the Unit in Position ModelConnecting Up and Purging the Circuit If you have used ThenTo check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics