INSTALLING THE INDOOR UNIT
Purging the Unit
On delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as follows.
Unscrew the caps at the end of each pipe.
Result: All inert gas escapes from the indoor unit.
➢To prevent dirt or foreign objects from getting into the pipes during installation, do NOT remove the caps completely until you are ready to connect the piping.
Connecting the Assembly Cable
❊The designs and shape are subject to change according to the model.
Connector cover
The outdoor unit is powered from the indoor unit via the assembly cable. If the outdoor unit is more than five metres away from the indoor unit, the cable must first be extended to a maximum of “L”m/ft.
1Extend the assembly cable if necessary.
2Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit; if necessary, refer to page 21.
3Remove the screw securing the connector cover, then open the connector cover.
4 | Remove three screws securing the front panel, then detach the front panel |
| from the indoor unit. |
|