INSTALLING THE OUTDOOR UNIT

Connecting the Cables to the Outdoor Unit

One electric cable must be connected to the outdoor unit:

The assembly cable connecting the indoor unit to the outdoor unit

1Remove the terminal board cover on the side of the outdoor unit.

2Connect the assembly cable to terminals as shown in the figure.

Each wire is labelled with the corresponding terminal number.

Each wire from the terminal number of the indoor unit. Shall be comected with the same terminal number of its outdoor unit.

3Connect the earth wires to the earth terminals.

Refer to the page 39 for further details on how to check that earthing is correct.

✴✴07/09✴✴

ENGLISH

 

AS12A5(A6)MC

 

AS12AA(AB)MC

4Replace the terminal board cover, carefully tightening the screw.

AS12A5(A6)MC

Indoor

N1 1

2

3

N

L

E

unit

 

 

 

 

 

 

 

1

 

 

N

L

E

 

N

L

1

 

 

E

Outdoor

 

 

 

 

 

unit

 

 

 

 

 

 

 

N

L

1

2

3

 

NL E Earth terminal

✴✴07/09✴✴ / AS12AA(AB)MC

Indoor

(A)

1

 

 

L1

L2

E

unit

 

 

 

 

 

 

 

 

 

1

 

 

L1

L2

E

Outdoor

L1

L2

1

 

 

E

 

 

 

 

 

 

unit

 

 

 

 

 

 

 

 

 

L1

L2

1

2

3

 

 

 

L1

L2

E

 

Earth

 

 

 

 

 

 

terminal

 

✴✴18/24✴✴

AS18A5(A6)RC

AS18A9(A0)RCD / AS24A1(A2)RC

Indoor A B 1 2 3 4

E

Indoor A B 1 2 3 4

E

unit

 

unit

 

A B 1 2

E

A B 1 2 3

E

A B 1 2

E

A B 1 2 3

E

Outdoor

 

Outdoor

 

unit

 

unit

 

A B 1 2 3 4 L1 L2

A B 1 2 3 4 L1 L2

 

Earth

 

Earth

 

L1 L2 E terminal

 

L1 L2 E terminal

Circuit Breaker(Main Power)

Circuit Breaker(Main Power)

Circuit Breaker(Main Power)

Circuit Breaker(Main Power)

E-37

Image 37
Contents Manuel D’UTILISATION & Manuel D’INSTALLATION Safety Precautions Contents Indoor Unit View of the UnitOutdoor Unit Remote Control Buttons and Display Getting Started Installing the Remote Controller Holder Inserting the Remote Control BatteriesSelecting with the Remote Control Using with the indoor unitWay Function To obtain anSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction VerticallyTo Cancel the On Timer Setting the On TimerTo Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsMode Outdoor Temperature Indoor Temperature Indoor Humidity Temperature and Humidity RangesIf the air conditioner is used at... Then Model AS07A5A6MA/AS09A5A6MA/AS12A5A6MC /AS12AAABMC Cleaning Your Air ConditionerAUTO, Cool Solving Common ProblemsInstalling a Filter Option Model Technical SpecificationsAS24A1A2RC AS18A5A6RCInstallation Manual Purging the Unit Indoor Unit Deciding on Where to Install the Air Conditioner30mm1inch or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesAccessories in the Outdoor Unit Case Then follow Steps Fixing the Installation PlateWall Window frame Purging the Unit Connecting the Assembly CableAS18A9A0RCD / AS24A1A2RC To install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HosePipe Installing and Connecting the Indoor Unit Assembly PipingTorque Depth a Cutting/Extending the Piping07/09 Connecting the Cables to the Outdoor UnitAS12A5A6MC 18/24Electrical Work Auxiliary Circuit Breaker50 19 Checking Correct EarthingModel Fixing the Unit in PositionIf you have used Then Connecting Up and Purging the CircuitPerforming Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics