Samsung US24A1(A2)RC, US12AA(AB)MC, US12A5(A6)MC, US18A5(A6)RC AS18A9A0RCD / AS24A1A2RC

Page 33

INSTALLING THE INDOOR UNIT

Connecting the Assembly Cable (cont.)

5Detach the control box from the indoor unit.

6Install the conduit kit. (The conduit kit is optional)

7Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals as shown in the figure.

Each wire is labelled with the corresponding terminal number.

8Pass the other end of the cable through the 65mm( 2 169 inch) hole in the wall.

9Reinstall the control box, then tighten the C screw.

The C screw is provided with this manual.

10Install the D terminal block cover, tightening the E screws.

The D terminal block cover and E screws are provided with this manual.

11Replace the front panel, carefully tightening the screws.

12Reinstall the front grille.

13For further details on how to plug the other end of the assembly cable into the outdoor unit, refer to page 37.

ENGLISH

Control Box

A

B

The conduit kit is optional(A and B).

C

Control Box

 

 

E

D Terminal

block

cover

AS12A5(A6)MC

Indoor

N1 1

2

3

N

L

E

unit

 

 

1

 

 

N

L

E

 

N

L

1

 

 

E

Outdoor

 

 

 

 

 

unit

 

 

 

 

 

 

 

 

 

 

 

Earth

 

 

 

 

 

terminal

✴✴07/09✴✴ / AS12AA(AB)MC

Indoor

(A) 1

L1

L2

E

unit

 

 

1

L1

L2

E

 

L1 L2 1

 

 

E

Outdoor

unit

Earth terminal

AS18A5(A6)RC

Indoor

A

B

1

2 3

4

E

unit

 

 

A

B

1

2

 

E

Outdoor

A

B

1

2

 

E

 

 

 

 

 

 

unit

 

 

 

 

 

 

 

 

 

 

 

Earth

 

 

 

 

 

terminal

AS18A9(A0)RCD / AS24A1(A2)RC

Indoor

A

B

1

2

3

4

E

unit

 

 

A

B

1

2

3

 

E

Outdoor

A

B 1

2

3

 

E

 

 

 

 

 

 

 

unit

 

 

 

 

 

 

 

 

 

 

 

 

 

Earth

 

 

 

 

 

 

terminal

E-33

Image 33
Contents Manuel D’UTILISATION & Manuel D’INSTALLATION Safety Precautions Contents Indoor Unit View of the UnitOutdoor Unit Remote Control Buttons and Display Getting Started Installing the Remote Controller Holder Inserting the Remote Control BatteriesSelecting with the Remote Control Using with the indoor unitWay Function To obtain anSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction VerticallyTo Cancel the On Timer Setting the On TimerTo Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsTemperature and Humidity Ranges Mode Outdoor Temperature Indoor Temperature Indoor HumidityIf the air conditioner is used at... Then Model AS07A5A6MA/AS09A5A6MA/AS12A5A6MC /AS12AAABMC Cleaning Your Air ConditionerAUTO, Cool Solving Common ProblemsInstalling a Filter Option Model Technical SpecificationsAS24A1A2RC AS18A5A6RCInstallation Manual Purging the Unit Indoor Unit Deciding on Where to Install the Air Conditioner30mm1inch or more Air Conditioner and Accessories Accessories in the Indoor Unit CaseAccessories in the Outdoor Unit Case Fixing the Installation Plate Then follow StepsWall Window frame Purging the Unit Connecting the Assembly CableAS18A9A0RCD / AS24A1A2RC To install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HoseInstalling and Connecting the Indoor Unit Assembly Piping PipeTorque Depth a Cutting/Extending the Piping07/09 Connecting the Cables to the Outdoor UnitAS12A5A6MC 18/24Electrical Work Auxiliary Circuit Breaker50 19 Checking Correct EarthingModel Fixing the Unit in PositionIf you have used Then Connecting Up and Purging the CircuitPerforming Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics