Samsung US12A5(A6)MC, US12AA(AB)MC, US18A5(A6)RC, US18A9(A0)RCD Placing the Indoor Unit in Position

Page 43

COMPLETING THE INSTALLATION

Placing the Indoor Unit in Position

Once you have checked that there are no leaks in the system, you can insulate the piping, hose and cables and place the indoor unit on the installation plate.

1To avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit.

2Wrap the refrigerant pipes and the drain hose located at the rear of the indoor unit up in the absorbent pad.

Triply wind the pipes and hose to the end of the indoor unit with the absorbent pad (make intervals of 20mm / 34 inch).

3Wind insulating tape around the pipes, assembly cable and drain hose.

4Place the resulting bundle carefully in the lower part of the indoor unit, making sure that it does not jut out from the rear of the indoor unit.

5Hook the indoor unit on to the installation plate and move the unit to the right and left until you are sure that it is securely in place.

6Finish wrapping vinyl tape around the rest of the piping leading to the outdoor unit.

7Using clamps (optionally supplied), attach the piping to the wall wherever possible.

ENGLISH

Installation plate

E-43

Image 43
Contents Manuel D’UTILISATION & Manuel D’INSTALLATION Safety Precautions Contents Indoor Unit View of the UnitOutdoor Unit Remote Control Buttons and Display Getting Started Installing the Remote Controller Holder Inserting the Remote Control BatteriesTo obtain an Using with the indoor unitSelecting with the Remote Control Way FunctionSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction VerticallyTo Cancel the On Timer Setting the On TimerTo Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsMode Outdoor Temperature Indoor Temperature Indoor Humidity Temperature and Humidity RangesIf the air conditioner is used at... Then Model AS07A5A6MA/AS09A5A6MA/AS12A5A6MC /AS12AAABMC Cleaning Your Air ConditionerAUTO, Cool Solving Common ProblemsInstalling a Filter Option Model Technical SpecificationsAS24A1A2RC AS18A5A6RCInstallation Manual Purging the Unit Indoor Unit Deciding on Where to Install the Air Conditioner30mm1inch or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesAccessories in the Outdoor Unit Case Then follow Steps Fixing the Installation PlateWall Window frame Purging the Unit Connecting the Assembly CableAS18A9A0RCD / AS24A1A2RC To install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HosePipe Installing and Connecting the Indoor Unit Assembly PipingTorque Depth a Cutting/Extending the Piping18/24 Connecting the Cables to the Outdoor Unit07/09 AS12A5A6MCElectrical Work Auxiliary Circuit Breaker50 19 Checking Correct EarthingModel Fixing the Unit in PositionIf you have used Then Connecting Up and Purging the CircuitPerforming Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics