GE ASQ28 owner manual Install the Security Bracket and the Foam TOP Window Gasket

Page 12

Window Installation Instructions

8INSTALL THE SECURITY BRACKET AND THE FOAM TOP WINDOW GASKET

AAttach the security bracket with a type B screw.

BCut the foam top window gasket to the window width.

CStuff the foam between the glass and the window to prevent air and insects from getting into the room.

9INSTALL THE AIR CONDITIONER IN THE CASE

ASlide the air conditioner into the case. Reinstall the 2 front side ground screws removed earlier on each side of the case.

IMPORTANT: The ground screws must be reinstalled to ensure a proper ground.

BPlace the bottom inner case gasket between the bottom of the air conditioner and the inside bottom of the case. Fold up the ends on both sides and push them in.

Front of air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom inner

 

 

 

 

 

conditioner

 

 

 

 

 

 

case gasket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAttach the front grille to the case by inserting the tabs on the grille into the slots on the front of the case. Push the grille in until it snaps into place.

Guide the lever carefully through the grille as you push it in.

DSecure the front grille to the case by replacing the screw removed in Step 4.

Replace the filter and the inlet grille.

Caulk or weather-strip any gaps or openings to the outside to seal the installation.

The installation is now complete.

12

Image 12
Contents Air Conditioners Write the model and serial numbers here Model # Serial #Safety Precautions Do not use an adapter plug with this applianceUSE of Extension CORDS-115-Volt models only Ge.comRemote Control About the controls on the air conditionerPower Outage Recovery Feature Cool ModeFan Mode Vent ControlCare and cleaning of the air conditioner How to Insert the BatteriesGrille and Case Outdoor CoilsBefore YOU Begin Electrical RequirementsTools YOU will Need Window Installation Instructions Parts IncludedWindow Requirements Storm Window RequirementsPrepare the Window Remove the Front Grille if AttachedRemove the AIR Conditioner from the Case Prepare the CaseInstall the Case Install the Case in the WindowInstall the Security Bracket and the Foam TOP Window Gasket Install the AIR Conditioner in the CaseThrough-the-Wall Installation Instructions-Optional Finish the Wall OpeningTroubleshooting Tips… Normal Operating SoundsGeneral Electric Company Consumer Product Ownership Registration GE Air Conditioner Warranty What Is Not CoveredGE Will Replace Schedule Service Parts and AccessoriesConsumer Support GE Appliances Website Real Life Design StudioAcondicionadores de Aire Instrucciones de Seguridad ¡ADVERTENCIA InstruccionesAcerca de los controles en el acondicionador de aire Control remotoFunción de recuperación de pérdida de energía Modo Cool FrioModo de FAN Ventilador Control de la ventilaciónCuidado y limpieza del acondicionador de aire Precaución no Opere elAntes DE Iniciar Requisitos ElectricosHerramientas QUE Usted Necesitará Partes IncluidasRequisitos Para LA Ventana Requisitos DE UNA Ventana DE TormentasPrepare LA Ventana Retire LA Parrilla Frontal SI Está PegadaPrepare LA Caja Retire EL Acondicionador DE Aire DE LA CajaInstale LA Caja EN LA Ventana Instale LA CajaDE LA Ventana Instale EL Acondicionador DE Aire EN LA CajaInstrucciones de instalación a través de la pared-opcional ImportanteTermine LA Abertura EN LA Pared Solucionar problemas Sonidos de operación normales Garantía de su acondicionador de aire de GE GE reemplazaráLo que no está cubierto Un añoApoyo al Consumidor Página Web de GE Appliances Solicite una reparaciónGarantías ampliadas Piezas y accesorios