The following information is prepared for safe installation of the unit.

This unit can be placed on a flat table or installed in the rack. It should not be used vertically or skew, but

horizontally. The location of the unit and the composition of wiring are very important in properly operating

the system. When equipment is placed too close or if ventilation is not properly done, system may not

work properly, and maintenance of the system may be difficult. In order to prevent system failure and to

reduce system shut-down by outside environmental factors, air circulation in the system operating room,

and the cover of the unit must be fixed. Do not open the cover voluntarily because high voltage within the

unit may cause electric shock.

PHYSICAL & ENVIRONMENTAL

Operating Temperature : 0 °C to 40 °C

Maintenance Temperature : -20 °C to 60 °C

Operating Humidity : 20% to 85% (RH)

Maintenance Humidity : 20% to 95% (RH)

Power Supply : 100 ~ 240 VAC

Power Consumption : less than 14W

Frequency : 50 / 60 Hz

CAUTIONS

When system is operated, input voltage range must be within 10% of nominal voltage, and power consent should be grounded. Heating devices such as hair dryer, iron, refrigerator should not be used together. For safe power supply, AVR (Automatic Voltage Regulator) is recommended.

The connector linked to this equipment can affect EMI, so it is recommended to coil the CORE-FERRITE for use.

2-1

Image 10
Contents Digital Multiplexer Important Safeguards Iii Contents Appendix B Checking Points in Trouble Introduction IntroductionName of parts and Function Move → Rear panel Preparing for the Installation Physical & EnvironmentalPrecautions when Installing Digital Multiplexer Unpacking Connecting to normal VCR and Monitor Connecting to Other DevicesConnecting to S-VHS VCR and S-VHS Monitor Connecting to Time Lapse VCR Connecting to Alarm Sensor Remote Control by connecting to PC Ascii@ Spot OUT Control Remote Control using SSC-1000RS-485Monitor OUT Control Spot OUT ControlBasic Method to use When desiring to see in the live screen/replay screenWhen desiring to see in the Triplex screen Initial operationWhen desiring to see in the Full screen When desiring to see in the division screenWhen desiring to see automatic sequential conversion screen When desiring to see in the zoom screen When desiring to see the stop screenFull Mode 2TIMES Zoom Times Zoom When desiring to see in the record screen When desiring to see in the PIP screenWhen desiring to see output of VCR as it is REC OUT SET Type TLV Setting of Program MenuRecord setting of each camera Duty SET Reservation OFFREC Reservation Start Time REC Duty SET CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9END Time ALL Setting of display modeSequence Loss Detect Loss Info Alarm Info Motion Info PB Display ALL Spot OUT Cvbs PIP SizeAlarm S/W Time SequenceSetting of title by channel CH15 onIjklmnopqrstuvwxyz Title SETDATE/TIME SET Display Type Setting of alarm Setting of motionSensitivity OFF ↔ LOW ↔ Medium ↔ High List Update OFF ↔ onXxxxx Motion OUT OFF ↔ onPassword Check OFF Alarm Buzzer Loss Buzzer Summer Time System settingPassword Change Baud RatePassword Change Password Check NEW Password Confirm +++++++++++++++++ + - - - - +Time Lapse record mode Normal record modeRecording Reservation record Weight value REC Duty recordAlarm weight value record REC DutyAlarm record Alarm occurrence conditionsAlarm release Alarm signal standardOperation in video loss Alarm/Loss list referenceOperation in motion detection Appendix a Specifications Image inputOutside Drawing When record is not done Appendix B Checking points in trouble