Samsung SDM-090P, SDM-160MP, SDM-160P manual System setting, Baud Rate, Password Change

Page 32

Digital Multiplexer

7. System setting

Set application of password change, buzzer and summer time.

The following screen is displayed if pressing the “ENTER” button with the blinking indication placed at the “7. SYSTEM SET” on the main menu screen:

[SYSTEM SET]

RS-485 ADDR SET

1

BAUD RATE

38400

PASSWORD CHANGE...

PASSWORD CHECK

OFF

ALARM BUZZER

OFF

LOSS BUZZER

OFF

SUMMER TIME

OFF

LANGUAGE SELECT

OFF

- The blinking character moves if pressing “”, “” button. - The setting value is changed if pressing “”, “” button. RS-485 ADDR SET: 1~253

Set the address of this unit in using the RS-485. BAUD RATE: 4800 ↔ 9600 ↔ 19200 ↔ 38400 ↔ 4800

Set the baud rate of RS-232 and RS-485.

PASSWORD CHECK: ON ↔ OFF

Set existence of the password inspection in entering into the main menu.

ALARM BUZZER: ON ↔ OFF

Set existence of alarm sound in the occurrence of alarm.

LOSS BUZZER: ON ↔ OFF

Set existence of alarm sound in the occurrence of loss.

SUMMER TIME: ON ↔ OFF

Set application of summer time.

Summer time operation delays the current time from the setting time by an hour and move up by an hour from the released time and then return to the original time.

LANGUAGE SELECT: ON ↔ OFF

With the main meun “ON”, “LANGUAGE SELECT” will be displayed.

Select a language you want by using “” , “ ” button and then press “ENTER” , “SETUP MENU” will be displayed in the language you want.

ENGLISH

ESPAÑOL

FRANÇAIS

ITALIANO

GERMAN

5-9

Image 32
Contents Digital Multiplexer Important Safeguards Iii Contents Appendix B Checking Points in Trouble Introduction IntroductionName of parts and Function Move → Rear panel Preparing for the Installation Physical & EnvironmentalPrecautions when Installing Digital Multiplexer Unpacking Connecting to S-VHS VCR and S-VHS Monitor Connecting to Other DevicesConnecting to normal VCR and Monitor Connecting to Time Lapse VCR Connecting to Alarm Sensor Remote Control by connecting to PC AsciiRemote Control using SSC-1000RS-485 Monitor OUT Control@ Spot OUT Control Spot OUT ControlWhen desiring to see in the live screen/replay screen When desiring to see in the Triplex screenBasic Method to use Initial operationWhen desiring to see in the Full screen When desiring to see in the division screenWhen desiring to see automatic sequential conversion screen Full Mode 2TIMES Zoom Times Zoom When desiring to see the stop screenWhen desiring to see in the zoom screen When desiring to see output of VCR as it is When desiring to see in the PIP screenWhen desiring to see in the record screen Setting of Program Menu Record setting of each cameraREC OUT SET Type TLV Duty SET Reservation OFFEND Time REC Duty SET CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9REC Reservation Start Time Setting of display mode Sequence Loss Detect Loss Info Alarm Info Motion InfoALL PB Display ALL Spot OUT Cvbs PIP SizeAlarm S/W Time SequenceSetting of title by channel CH15 onDATE/TIME SET Display Type Title SETIjklmnopqrstuvwxyz Setting of alarm Setting of motionList Update OFF ↔ on XxxxxSensitivity OFF ↔ LOW ↔ Medium ↔ High Motion OUT OFF ↔ onSystem setting Password ChangePassword Check OFF Alarm Buzzer Loss Buzzer Summer Time Baud RatePassword Change Password Check NEW Password Confirm +++++++++++++++++ + - - - - +Recording Normal record modeTime Lapse record mode Weight value REC Duty record Alarm weight value recordReservation record REC DutyAlarm occurrence conditions Alarm releaseAlarm record Alarm signal standardOperation in motion detection Alarm/Loss list referenceOperation in video loss Appendix a Specifications Image inputOutside Drawing When record is not done Appendix B Checking points in trouble