2. Solid Wall or Stud Partition
(Using Rear Fixing Points on Shower Control)
2.1Refer to section: ‘1. Solid Wall or
Stud Partition Installation (Using Securing Brackets - Mounting off Front Face)’ and follow instructions 1 to 4.
2.2Cut away the plasterboard or brick work to the required depth.
Important! This depth ‘X’ will depend on the finished wall thickness e.g. tiles or facia board. Refer to the table for this measurement.
For stud partitions depth ‘X’ refers to the distance from the rear mounting e.g. wooden baton, to the front of the wall (before tiling).
Rear Support
Depth ‘X’
Finished Wall
Surface
Finished Wall
Thickness
Finished Wall Thickness | Wall Cutout Depth ‘X’ |
(e.g. tile and adhesive) |
|
6 mm | 76 - 58 mm |
8 mm | 74 - 56 mm |
10 mm | 72 - 54 mm |
|
|
12 mm | 70 - 54 mm |
14 mm | 68 - 54 mm |
|
|
16 mm | 66 - 54 mm |
|
|
18 mm | 64 - 54 mm |
20 mm | 62 - 54 mm |
22 mm | 60 - 54 mm |
24 mm | 58 - 54 mm |
|
|