COMMISSIONING
Maximum Temperature Setting
The Thermostatic Shower Controls are preset at approximately 43 °C at the factory. If adjustment is required, set the maximum temperature as follows:
Note! Make sure that the hot water temperature is at least 10 °C above the required maximum showering temperature.
1.
2.Unscrew the temperature hub with a 3 mm hexagon key (supplied).
3.Remove the temperature hub and temperature hub spacer (if fitted).
4.Operate the flow control lever.
5.Rotate the spindle until required maximum blend temperature is obtained at discharge point (clockwise = decrease temperature).
Caution! When resistance is felt do not use force to turn any further, as this can damage the internal parts.
6.Once the desired maximum blend temperature has been achieved, refit the temperature hub and temperature hub spacer (if required) without disturbing the spindle, positioning the temperature hub (or temperature hub spacer) so that the lug is against the left side of the stop on the cartridge face, thus preventing anticlockwise rotation which could damage the internal mechanism (refer to illustration). Make sure that the temperature has not altered.
Note! The temperature hub spacer will be required where the finished wall thickness is greater than 8 mm.
Cartridge Face Stop
Rear Face of
Temperature
Hub / Spacer
|
| Temperature |
Temperature |
| Hub / Spacer Lug |
Temperature |
| |
Spindle |
| |
| Hub Spacer |
|
| Temperature Hub | Temperature |
|
| |
| Screw | Knob |
|
|
22