COMMISSIONING

Maximum Temperature Setting

The Thermostatic Shower Controls are preset at approximately 43 °C at the factory. If adjustment is required, set the maximum temperature as follows:

Note! Make sure that the hot water temperature is at least 10 °C above the required maximum showering temperature.

1.Pull-off the temperature knob.

2.Unscrew the temperature hub with a 3 mm hexagon key (supplied).

3.Remove the temperature hub and temperature hub spacer (if fitted).

4.Operate the flow control lever.

5.Rotate the spindle until required maximum blend temperature is obtained at discharge point (clockwise = decrease temperature).

Caution! When resistance is felt do not use force to turn any further, as this can damage the internal parts.

6.Once the desired maximum blend temperature has been achieved, refit the temperature hub and temperature hub spacer (if required) without disturbing the spindle, positioning the temperature hub (or temperature hub spacer) so that the lug is against the left side of the stop on the cartridge face, thus preventing anticlockwise rotation which could damage the internal mechanism (refer to illustration). Make sure that the temperature has not altered.

Note! The temperature hub spacer will be required where the finished wall thickness is greater than 8 mm.

Cartridge Face Stop

Rear Face of

Temperature

Hub / Spacer

 

 

Temperature

Temperature

 

Hub / Spacer Lug

Temperature

 

Spindle

 

 

Hub Spacer

 

 

Temperature Hub

Temperature

 

 

 

Screw

Knob

 

 

22

Image 22
Contents These instructions are to be left with the user Contents Safety Warnings IntroductionPack Contents Dimensions Pressures SpecificationsTemperatures Flow RatesConnections Thermostatic Shut-downGravity fed system Installation RequirementsKey to symbols Gas heated systemHot water system thermal store Mains pressurised instantaneousPumped system Installation GeneralInstallation Methods Mm Max Outlet Pipe BIR Page Page Refer to section ‘1. Solid Wall or Page Fit the securing brackets to the shower valve M5 Fixing Holes Securing Screws Control Assembly ‘Commissioning’ Reversed Supplies Maximum Temperature Setting CommissioningOperation Fault Diagnosis Symptom CAUSE/RECTIFICATIONCleaning Filters MaintenanceLubricants Spare Parts Page Customer Service