Kohler Discovery manual Control Assembly

Page 19

Control Assembly

1.Pull off the temperature knob.

Concealing Plate

2.Carefully separate the concealing plate from the backplate.

Note! Use a screwdriver in the cutout to assist separation.

3. Fit the backplate to the shower control and secure with the three securing screws (removed from the building-in shroud). Make sure that the seal is fully compressed on the finished wall surface.

Note! If the finish is particularly uneven (i.e. due to grout lines), apply a small amount of silicone sealant to ensure a seal.

Caution! Do not overtighten the screws as this may cause the backplate to distort, preventing the fitting of the control knobs.

4.Align the flow control hub with the taper towards the top of the shower control (refer to illustration).

Cutout

Flow Control Hub

Temperature Knob

Backplate

Securing Screws

(Seal on Rear)

 

19

Image 19
Contents These instructions are to be left with the user Contents Introduction Safety WarningsPack Contents Dimensions Flow Rates SpecificationsTemperatures PressuresThermostatic Shut-down ConnectionsGas heated system Installation RequirementsKey to symbols Gravity fed systemHot water system thermal store Mains pressurised instantaneousPumped system General InstallationInstallation Methods Mm Max Outlet Pipe BIR Page Page Refer to section ‘1. Solid Wall or Page Fit the securing brackets to the shower valve M5 Fixing Holes Securing Screws Control Assembly ‘Commissioning’ Reversed Supplies Commissioning Maximum Temperature SettingOperation Symptom CAUSE/RECTIFICATION Fault DiagnosisCleaning Filters MaintenanceLubricants Spare Parts Page Customer Service