mode

For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage.. When the air conditioner is operating in Cool/Heat (ARJQ) mode;

1.

Press the Timer button..

 

2.

Press the

button until (

) indicator starts to blink..

3.

Press the SET button to set the

mode..

 

--

) indicator will keep blinking and you can set the time..

4.Press the button to set the time..

-- You can set the time in half hour unit from 30 minutes (0..5 on the display) ~ 3 hours and hour unit from 3~12 hours..

-- Time can be set from minimum 30 minutes to maximum 12 hours..

 

-- Default time setting for the

mode is 8 hours..

 

 

5. Press the SET button to complete the

mode setting..

 

 

-- (

) indicator and the set time of the

mode will be displayed on

 

the remote controller display..

 

 

 

-- Timer indicator (

) will be displayed on the indoor unit display..

 

 

--

mode setting will be cancelled if you don't press the SET button within

 

10 seconds after setting the time.. Therefore, check for the ( ) indicator on the

 

 

 

 

remote controller display and the Timer indicator ( ) on the indoor unit display..

 

Cancel

fFPress the

button to make the set time to display as

,

 

 

and press the SET button..

 

 

Remote controller display

 

 

 

 

 

 

 

 

 

 

 

Additional options available in

mode

 

You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.

Fan speed will be adjusted automatically according to themode.

However, If you selectmode while heating operation is on, you can adjust fan speed.

When themode is on.

In Cool mode: Air flow direction will be adjusted automatically.

In Heat (ARJQ) mode: Adjusting air flow direction is available.

Temperature and fan speed change inmode

•• Fall asleep: Eases you into sleep by dropping the temperature..

•• Sound sleep: Relaxes your body and raises your temperature slightly..

•• Wake up: Allows you to wake up from comfortable intermittent air and it makes you feel refreshed..

• Recommended set temperature is between 25 °C ~ 27 °C for cooling and 21 ˚C~23 ˚C for heating (ARJQ).

• If the set temperature is too low, you may feel cold during sleep or catch a cold..

Optimal operation hour of mode is 8 hours.. Therefore, if the time is set too short or long, you may not feel as comfortable as you would expect..

If the mode is set over 5 hours, Wake up stage will begin when 1 hour is remaining in the operation time and the air conditioner will stop automatically..

When the On timer and the function is set simultaneously, the air conditioner will only apply the function that was set later..

English-20

MG_BETTER_ON&OFF_A3050_IB&IM_EN_DB68-04534A.indd 20

2014/9/26 16:28:03

Image 20
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4For Power Supply English-5For Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Checking the name of the parts Main partsDisplay English-12English-13 Checking the remote controllerRemote controller buttons Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Adjusting the air flow direction English-17Setting the On/Off timer Setting the On timerWhen the air conditioner is off English-18English-19 Setting the Off timerWhen the air conditioner is on Additional options available ModeEnglish-20 English-21 When the air conditioner is operating in Cool modeStep cooling function English-22 Using the Fast functionUsing the Comfort function Using the Single user function Single user function is only available in Cool modeEnglish-23 Blink and press the SET buttonUsing the Virus Doctor function When the air conditioner is operatingEnglish-24 Press the SET button to set the Virus Doctor functionEnglish-25 Using the Auto clean functionChecking the usage time Setting the Beep sound Resetting the Filter clean reminderSetting the Display option English-26Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger English-27Cleaning the Air filter Removing the Air filterEnglish-28 Remove the Air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-29 Maintaining the air conditioner English-30Troubleshooting TemperatureAdjustment is not English-31Button or disconnect the power plug/switch Check the Drains have been cleared Regular MaintenanceError is indicated Heard when refrigerant flow movement changes. It is normalGeneral information English-33Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitEnglish-35 Where sulfide gas existsOutdoor Unit When installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-36  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-37Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsAssembling the hanger screw English-39This QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-40Assembling the Cover panel After mounting the indoor unit English-41Connecting the assembly cable Cable specificationConnecting the cable English-42English-43 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number English-44 Smooth the cut edgesCut off the remaining foam insulation TorqueEnglish-45 Evacuating the indoor unitCutting or extending the pipe Cracked English-46Correct Inclined Drain hose installation English-47Change the direction only when it is necessary English-48Shield Downwards as seen in the pictureEvacuating the connected pipes English-49Connect a drain hose to the drain plug Ensure that condensation draining is adequateOuter Torque Adding RefrigerantEnglish-50 English-51 Cylinder with siphonPlease fill in with indelible ink 1975Performing the gas leak tests English-52Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-53 18/24JR 660 340 18JQ 24JQ 645Smart Install mode English-54English-55 Off / Blinking / OnFinal check and trial operation English-56Packing and unpacking guide English-57How to connect your extended power cables English-58Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-59 Questions or COMMENTS? 0211