Samsung AR18JRSDBWKXMG manual Cleaning the air conditioner, Cleaning the indoor unit, English-27

Page 27

Cleaning the air conditioner

Make sure to turn off the power of the indoor unit and cut-off

CAUTION the power supply before cleaning the air conditioner.

Cleaning the indoor unit

Wipe the surface of the unit with a slightly damp micro fiber cloth when

needed.

• Contact the service center when you clean the indoor unit

heat exchanger because it needs to be disassembled.

Since the panel of the indoor unit is easily scratched, you should use a micro fiber cloth to clean the panel.

When you use the micro fiber cloth, slightly dampen the cloth and remove any debris on the cloth to avoid scratches.

• Do not clean the display using alkaline detergent.

 

• Do not use sulfuric acid, hydrochloric acid, organic solvents

CAUTION

 

(such as thinner, kerosene and acetone etc.) to clean the

 

 

surface of the product or put any stickers on it.

 

They may damage the surface of the air conditioner.

06 OTHERS

Cleaning the outdoor unit heat exchanger

When dust accumulates on the heat exchanger, it may decrease cooling performance. Therefore, clean it regularly.

Spray water to clean the dust.

• If it is difficult to clean the outdoor unit heat exchanger on

your own, contact service center.

• Be careful with the sharp edges on the CAUTION outdoor unit heat exchanger.

Heat exchanger

(Illustration may differ slightly depending on the models)

English-27

MG_BETTER_ON&OFF_A3050_IB&IM_EN_DB68-04534A.indd 27

2014/9/26 16:28:06

Image 27
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautionsEnglish-5 For Power SupplyEnglish-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 English-11 Technical SpecificationsEnglish-12 Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-13 Inserting the batteries Remote controller displayLow Battery warning Storing the remote controllerBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 English-17 Adjusting the air flow directionEnglish-18 Setting the On/Off timerSetting the On timer When the air conditioner is offSetting the Off timer When the air conditioner is onEnglish-19 Mode English-20Additional options available When the air conditioner is operating in Cool mode Step cooling functionEnglish-21 Using the Fast function Using the Comfort functionEnglish-22 Blink and press the SET button Using the Single user functionSingle user function is only available in Cool mode English-23Press the SET button to set the Virus Doctor function Using the Virus Doctor functionWhen the air conditioner is operating English-24Using the Auto clean function Checking the usage timeEnglish-25 English-26 Setting the Beep soundResetting the Filter clean reminder Setting the Display optionEnglish-27 Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerRemove the Air filter from the main body Cleaning the Air filterRemoving the Air filter English-28Reassembling the Air filter English-29Top of the Air filter into the main body.. ➀ English-30 Maintaining the air conditionerEnglish-31 TroubleshootingTemperature Adjustment is notHeard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicatedEnglish-33 General informationIndoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitEnglish-35  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-36English-37 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsEnglish-39 Assembling the hanger screwEnglish-40 This QR code for detail video of indoor unit installationRemoving the screws Removing the Cover panel Before mounting the indoor unitEnglish-41 Assembling the Cover panel After mounting the indoor unitEnglish-42 Connecting the assembly cableCable specification Connecting the cableExtend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-43 Torque English-44Smooth the cut edges Cut off the remaining foam insulationEvacuating the indoor unit Cutting or extending the pipeEnglish-45 English-46 Correct InclinedCracked English-47 Drain hose installationDownwards as seen in the picture Change the direction only when it is necessaryEnglish-48 ShieldEnsure that condensation draining is adequate Evacuating the connected pipesEnglish-49 Connect a drain hose to the drain plugAdding Refrigerant English-50Outer Torque 1975 English-51Cylinder with siphon Please fill in with indelible inkEnglish-52 Performing the gas leak tests18/24JR 660 340 18JQ 24JQ 645 Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-53English-54 Smart Install modeOff / Blinking / On English-55English-56 Final check and trial operationEnglish-57 Packing and unpacking guideAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-58 Apply heat to the contraction tube to contract itEnglish-59 0211 Questions or COMMENTS?
Related manuals
Manual 58 pages 49.13 Kb Manual 60 pages 59.79 Kb