Samsung AP0AS0ANXSG manual Air Conditioner, Thank you for purchasing this Samsung product

Page 2

AP80S0A Series

AP0AS0A Series

Air Conditioner

user & installation manual

imagine the possibilities

Thank you for purchasing this Samsung product.

EN ES FR PT AR DB98-34514A-02

PAC_아프리카 중동향AP80S0A_IBIM_34514A-02_EN.indd 57

2015-04-23 오후 2:19:01

Image 2
Contents Questions or COMMENTS? 08000-7267864Air Conditioner Thank you for purchasing this Samsung productFeatures of your new air conditioner ContentsXXFailing to do so may result in electric shock or fire Safety precautionsImportant safety symbols and precautions XXThis may result in electric shock or fireFor Power Supply XXWhen there is fire, this may cause spread of fireXXThis may result in electric shock Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not clean the inside of the air conditioner by yourself Do not drink the water from the air conditionerOperational temperature and humidity range Using outdoor unitChecking the auxiliary power switch Auxiliary power switch Elcb Earth Leakage Circuit BreakerTo open the panel Viewing the partsMain parts Locking the control panel Control panel and the displayUsing the air conditioner with the control panel Installing the batteries Checking the remote controllerRemote controller button Auto Basic operationCool DryPress Button to adjust the desired temperature Press Button to start the operation of the air conditionerPress Adjusting the air flow directionTurbo operation Operation will operate for 30 minutesSmart saver operation Timer functionPress the button when the air conditioner is on You can turn the air conditioner off at your desired timeCleaning the outdoor unit heat exchanger Cleaning and maintaining the air conditionerCleaning the indoor unit Service centerCleaning the air filter Maintaining the air conditioner Periodical checksTroubleshooting Function See if the timer is already setClean the air filter if it is dirty If the message General information Installing the unitAccessing its internal components Make sure that you earth the cables Power supply line, fuse or circuit breakerDo not install the air conditioner in following places Complete, electric shock or fire may occurWhen moving with a fork lift Preparation for installationWhen moving with a crane Indoor outdoor unit type and combinationDeciding on where to install the product Indoor unitOutdoor unit Fix the wire on the groundWires on the wall Personal injury or property damageSelecting appropriate location for installation Wear protective goggles and mask before spraying When 3 sides of the outdoor unit are blocked by the wall When there are no tall obstacles around the outdoor unitWhen the air outlet is opposite the wall Space requirementsPipe length between the indoor and the outdoor unit When there is tall obstacle around the outdoor unitWhen installing 1 outdoor unit Installing the outdoor unit in harsh environments Preparing the installationInstalling duct for horizontal exhaust discharge When installing ductsInstalling indoor unit Installing outdoor unit AP80S0XOutdoor unit base mount and anchor bolt position Removing the connection pipe Connecting the pipesRefrigerant piping work InjuryOutdoor unit pipe connection AP80S0X Keep the pipe length as short as possibleModel name Liquid side mm Gas side mm Selecting refrigerant pipeTemper grade and minimum thickness of the refrigerant pipe Outer diameter mm/inch Minimum thickness mm Temper gradeNitrogen flushing brazing Direction of the pipe when brazingStoring refrigerant pipe Stored place Stored time Sealing typeCorrect Inclined Damaged surface Cracked Uneven thickness Cutting or flaring the pipesOuter diameter Dmm Pipe bending Connecting the drain hoseTightening flare connection part Piping materialFfPipe insulation Selecting the insulator of the refrigerant pipeInsulating refrigerant pipe To prevent moisture from enteringWiring work Electrical workPower supply and wire specification 0Not includedConnecting power and communication cable AP80S0A / AP0AS0ASelecting solderless ring terminal Screw Tightening torque kgf∙cm Connecting the power terminalFixing the power cable When using the exclusive terminal for grounding Grounding the power cableFfGrounding must be done by installation specialist Grounding workFfMake sure that grounding work is done in below procedure Grounding work procedureIf you are using the grounding on the switching board Procedure ExplanationGas leak test and vacuum drying Allowable refrigerant pipe length How to add refrigerantRefrigerant charging Setting the main PCB option Setting the option switches & function keysSetting the option switch of the indoor unit K1 K2 K3 K4Segment display Setting the outdoor unit KEYK2 Number of pressing Display PressingCheck lists after completing the installation Trial operation Trial operationInspection before trial operation Make sure that all the indoor units are properly operatingError display Error description Error diagnosisError display LED displayHow to connect your extended power cables Twist the wire cores together and push it in to the sleeveInsulation tape