Samsung AQV09PWCNCEE manual Using the Smart Saver function, From the moment you have set the timer

Page 15

Combining On Timer and Off Timer

If the air conditioner is on

If the air conditioner is off

 

 

Preset time on On timer is longer than Off timer

Preset time on On timer is shorter than Off timer

Ex) On timer : 3 hours, Off timer : 1 hour

Ex) On timer : 3 hours, Off timer : 5 hours

- The air conditioner will operate the Off timer after

- The air conditioner will operate On timer after 3 hours

1 hour from the moment you have set the timer.

from the moment you have set the timer.

Your air conditioner will turn on after 2 hours.

Your air conditioner will remain on for 2 hours and then

 

turn off automatically.

 

 

ENGLISH

• On timer and Off timer setting time should be different from each other.

• Press the Cancel button on the remote controller while timer combination is on. Both of the On and Off timer will be canceled and the indicator will disappear.

Using the Smart Saver function

This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode.

Press the Smart Saver button on the remote controller while the air conditioner is operating in Cool mode.

Smart Saver indicator and air swing indicator appears automatically on the remote controller display.

The air flow blades move up and down.

If the current set temperature is lower than 24°C, it will automatically raise to 24°C.

Cancel Press the Smart Saver button once again.

• Smart Saver function is only available in Cool mode.

• When Smart Saver function is activated, temperature range will be limited to 24°C~30°C.

If the desired temperature is lower than 24°C, turn off the Smart Saver function by pressing the Smart Saver button again.

Temperature/Fan speed can also be adjusted (see page 11 for instructions).

Air flow can be adjusted manually (see page 12 for instructions).

If you press the Mode button while the Smart Saver function is on, it will cancel the function.

15

Image 15
Contents Page Contents Wall socket Safety precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges Checking before useDisplay Power buttonChecking the name of the parts Main partsRemote controller buttons Checking the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press Button to adjust the temperatureVertical air flow Adjusting the air flow directionUsing the Turbo function Press the Air swing button on the remote controllerPress the Time Up or Time Down button to set the time When the air conditioner is on and in cool/heat modePress the button on the remote controller ModeSetting the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode Turn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is offUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on Opening the panel Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter Open the panel and put the Air filter outPeriodical checks Maintaining the air conditionerTroubleshooting Outdoor unit Heat exchanger during Heat mode in winter Flow movement changes. It is normalConnection General information Included Models RemarkAQV09P, AQV12P, AQV18P, AQV24P  a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerOutdoor Unit Where sulfide gas existsTop view Side view When installing 1 outdoor unitWhen installing more than 1 outdoor unit Space Requirements for Outdoor UnitAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Cable specificationConnecting the cable Installation Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationPass the pipe through the hole in the wall Put a flare nut slightly into the pipe and modify the flare Purging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined CrackedDrain hose installation Purging the connected pipes Connect a drain hose to the drain plugEnsure that condensation draining is adequate Adding Refrigerant Please fill in with indelible ink  the factory refrigerant charge of the product1975 Leak test with nitrogen before opening valves Performing the gas leak testsTo check for gas leaks on the outdoor unit To check for gas leaks on the indoor unitThen place the indoor unit on the installation plate Fixing the indoor unit in placeFixing the outdoor unit in place Final Check and Trial Operation Insulation tape to finish How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withPage 05 133 42 27Samsung 7267864, € 0.07/min 02-201-24-18Air Conditioner