Samsung AQV12PWCNCEE, AQV09PWCNEUR manual Using the Quiet function, Using the Auto Clean function

Page 16

Using the Quiet function

You can reduce the noise generated from an indoor unit.

Press the Quiet button on the remote controller while the air conditioner is operating in Cool/Heat mode.

Quiet indicator appears on the remote controller display.

The indoor unit will operate more quietly.

Cancel Press the Quiet button once again.

• If using a multi system, this function will work only when the Quiet function is set on all operated indoor units.

Using the Auto Clean function

Auto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit. Your indoor unit evaporates the moisture inside of the unit. Activate this function to provide you with more clean and healthier air.

Press the Auto Clean button.

When the air conditioner is turned off,

The Auto clean indicator on the indoor unit display appears and the Auto cleaning

function runs.

When the air conditioner is turned on,

After stopping the air conditioner operation , the Auto clean indicator on the indoor

unit display appears and the Auto cleaning function runs.

Auto Cleaning time can vary, depending on the previously used mode.

Auto(cool), Cool, Dry mode : approximately 30 minutes.

Auto(heat), Heat, Fan mode : approximately 15 minutes.

Cancel Press the Auto Clean button once again.

• When the air conditioner is turned on, the Auto clean function runs after

stopping the air conditioner operation.

16

Image 16 Contents
Page Contents Safety precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning Checking before use Operation rangesPower button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressAdjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerMode Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerAdditional options available in On timer mode Using the Smart Saver function From the moment you have set the timerIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Flow movement changes. It is normal Outdoor unit Heat exchanger during Heat mode in winterConnection Included Models Remark General informationAQV09P, AQV12P, AQV18P, AQV24P Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitWhen installing 1 outdoor unit When installing more than 1 outdoor unitSpace Requirements for Outdoor Unit Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number InstallationCut off the remaining foam insulation Smooth the cut edgesPass the pipe through the hole in the wall Purging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked Outer DiameterDrain hose installation Connect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate Adding Refrigerant  the factory refrigerant charge of the product Please fill in with indelible ink1975 Performing the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Then place the indoor unit on the installation plateFixing the outdoor unit in place Final Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishPage 42 27 Samsung 7267864, € 0.07/min02-201-24-18 05 133Air Conditioner
Related manuals
Manual 41 pages 12.62 Mb Manual 43 pages 23.26 Kb Manual 41 pages 10.61 Kb Manual 39 pages 33.67 Kb Manual 43 pages 50.37 Kb Manual 41 pages 45.51 Kb Manual 23 pages 13.22 Kb Manual 43 pages 9.83 Kb