Checking the remote controller

Point the remote controller towards the remote controller receiver of the indoor unit.

When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator() appears on the remote controller display.

Remote controller buttons

Remote controller display

Smart Saver

Less energy usage makes your space cool between the temperature range of 24°C~30°C.

Turbo

Operate in auto fan speed to cool quickly.

Quiet

Reduce noise generated from an indoor unit during operation.

Temp + -

Increase/Decrease the temperature by 1˚C.

Set themode on.

On Timer

Set the On Timer on.

Off Timer

Set the Off Timer on.

Time Up/Time Down

Adjust the time for timer/ mode.

This button doesn't have any function.

Power

Turn on/off the air conditioner.

Mode

Set one of the 5 operating modes (see pages 10-11 for instructions).

Auto Clean

Auto clean function – Dry inside of the indoor unit to get rid of odor.

Air swing

Activate/Deactivate air flow blade movement automatically up and down.

Fan

 

Adjust how much air flows through the air conditioner with the 4 different fan speeds such as Auto/Low/Medium/High.

Set

Set the timer/

mode.

Cancel

 

Cancel the timer/

mode.

• Make sure that the water does not get to the remote controller.

8

Image 8
Contents Page Contents Safety precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning Checking before use Operation rangesPower button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressAdjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerMode Press the Time Up or Time Down button to set the timeAdditional options available in On timer mode Setting the On/Off timerPress the On Timer/Off Timer button Using the Smart Saver function From the moment you have set the timerIf the air conditioner is on If the air conditioner is off Turn off automaticallyWhen the air conditioner is turned on Using the Quiet functionUsing the Auto Clean function Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Connection Outdoor unit Heat exchanger during Heat mode in winterFlow movement changes. It is normal AQV09P, AQV12P, AQV18P, AQV24P General informationIncluded Models Remark Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitWhen installing 1 outdoor unit When installing more than 1 outdoor unitSpace Requirements for Outdoor Unit Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Each wire is labeled with the corresponding terminal number InstallationPass the pipe through the hole in the wall Smooth the cut edgesCut off the remaining foam insulation Purging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked Outer DiameterDrain hose installation Ensure that condensation draining is adequate Purging the connected pipesConnect a drain hose to the drain plug Adding Refrigerant 1975 Please fill in with indelible ink the factory refrigerant charge of the product Performing the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesFixing the outdoor unit in place Then place the indoor unit on the installation plateFixing the indoor unit in place Final Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishPage 42 27 Samsung 7267864, € 0.07/min02-201-24-18 05 133Air Conditioner