Samsung AQV12PWCXCEE, AQV09PWCNEUR manual Maintaining the air conditioner, Periodical checks

Page 19

Maintaining the air conditioner

If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.

1.Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components.

2.Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness.

ENGLISH

Periodical checks

Refer to the following chart to maintain the air conditioner properly.

Type

Description

Every 2

Every 3

Every 4

Once a year

weeks

months

months

 

 

 

 

 

 

 

 

 

 

Clean the air filter (1)

 

 

 

 

 

 

 

 

 

Indoor

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

Thoroughly clean the heat exchanger (2)

 

 

 

unit

 

 

 

 

 

 

 

 

 

Clean the condensate drain pipe (2)

 

 

 

 

 

 

 

 

 

 

Replace the remote controller batteries (1)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the outside of the unit (2)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the inside of the unit (2)

 

 

 

 

 

 

 

 

 

 

Clean the electric components with jets of air (2)

 

 

 

Outdoor

 

 

 

 

 

Verify that all the electric components are firmly

 

 

 

unit

tightened (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean the fan (2)

 

 

 

 

 

 

 

 

 

 

Verify that all the fan assembly is firmly tightened (2)

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

 

: This check mark requires checking the indoor/outdoor unit periodically, following to the description to maintain the air conditioner properly.

(1) The described operations should be performed more frequently if the area of installation is very dusty.

(2) These operations must always be performed by qualified personnel. For more detailed information, see the installation part in the manual.

19

Image 19
Contents Page Contents Wall socket Safety precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges Checking before useDisplay Power buttonChecking the name of the parts Main partsRemote controller buttons Checking the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press Button to adjust the temperatureVertical air flow Adjusting the air flow directionUsing the Turbo function Press the Air swing button on the remote controllerPress the Time Up or Time Down button to set the time When the air conditioner is on and in cool/heat modePress the button on the remote controller ModePress the On Timer/Off Timer button Setting the On/Off timerAdditional options available in On timer mode Turn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is offUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Opening the panel Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter Open the panel and put the Air filter outPeriodical checks Maintaining the air conditionerTroubleshooting Flow movement changes. It is normal Outdoor unit Heat exchanger during Heat mode in winterConnection Included Models Remark General informationAQV09P, AQV12P, AQV18P, AQV24P  a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerOutdoor Unit Where sulfide gas existsTop view Side view When installing 1 outdoor unitWhen installing more than 1 outdoor unit Space Requirements for Outdoor UnitAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsCable specification Connecting the assembly cableConnecting the cable Installation Each wire is labeled with the corresponding terminal numberCut off the remaining foam insulation Smooth the cut edgesPass the pipe through the hole in the wall Put a flare nut slightly into the pipe and modify the flare Purging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined CrackedDrain hose installation Connect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate Adding Refrigerant  the factory refrigerant charge of the product Please fill in with indelible ink1975 Leak test with nitrogen before opening valves Performing the gas leak testsTo check for gas leaks on the outdoor unit To check for gas leaks on the indoor unitFixing the indoor unit in place Then place the indoor unit on the installation plateFixing the outdoor unit in place Final Check and Trial Operation Insulation tape to finish How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withPage 05 133 42 27Samsung 7267864, € 0.07/min 02-201-24-18Air Conditioner
Related manuals
Manual 41 pages 50.29 Kb Manual 41 pages 10.61 Kb Manual 43 pages 43.79 Kb Manual 39 pages 33.67 Kb Manual 43 pages 50.37 Kb Manual 41 pages 45.51 Kb Manual 23 pages 13.22 Kb Manual 43 pages 9.83 Kb