A2 Water heater piping  continued

Thermal expansion

Water hammer

If a backflow preventer, check valve, or pressure reducing valve is piped on cold water inlet of water heater, you must install an expansion tank on cold water supply line to prevent normal thermal expansion from repeat- edly forcing open T&P relief valve. The T&P relief valve is not intended for constant duty, such as relief of pressure due to repeated normal system expansion.

Refer to expansion tank manufacturer’s instructions for proper sizing.

Failure to follow the above could result in severe personal injury, death or substantial property damage.

Dishwashers, clothes washers, and fast-closing positive shutoff valves incorporated in the system all contribute to creating water shock. Install a water hammer arrester to prevent damage to pipes and appliances. See control manufacturer’s instructions for application and installation.

General piping information

For domestic water piping, see pages 8 through 12.

See pages 22–23, for domestic water recirculation piping.

See Table 1 for piping connections:

All plumbing must meet or exceed all local, state and national plumbing codes.

Use pipe dope or tape suitable for potable water.

Use isolation valves to isolate system components.

See Section B for Gas boiler and system piping or Sections C boiler and system piping with other boilers.

Table 1

Piping (Inches NPT)

Water

Connections

Recommended

Recirculation Dip Tube

Heater

Domestic

Boiler Water

Piping Between

Length

Diameter

Model

Water Heater

Water

Supply/

(inches)

(inches)

 

and Boiler

 

Inlet/Outlet

Return

 

 

 

 

 

 

30

¾

1

1

34

¾

 

 

 

 

 

 

40

¾

1

1

42

¾

 

 

 

 

 

 

60

¾

1 ¼

1 ¼

52

¾

 

 

 

 

 

 

80

¾

1 ¼

1 ½

61

¾

 

 

 

 

 

 

100

1 ½

1 ½

1 ½

25

1 ½

 

 

 

 

 

 

110

1 ½

1 ½

1 ½

32

1 ½

 

 

 

 

 

 

119

1 ½

2

2

32

1 ½

 

 

 

 

 

 

If domestic water-side pressure exceeds 70 psig, install a pressure reducing valve to prevent pressure spikes. Higher pressures can cause the heater pressure/temperature valve to lift or weep.

Part Number PLUS-E017-A/1206

13

Image 13
Contents Plus Line Hazard definitions Read this page firstContents Zoning with pumps Gold Plus 30/40/60/80 or Plus 40/60/80 Plus 100/110/119 Multiple water heater applications Codes A1 Pre-installationGold Plus 30/40/60/80 or Plus 40/60/80 see Figure Plus 100/110/119 see FigureCode restrictions National Standard Plumbing Code RestrictionsUniform Plumbing Code Water heater piping Temperature & pressure T & P relief valveAir vent Drain valve A2 Water heater piping Gold Plus 30/40/60/80 Or Plus 40/60/80 Option Plus 100/110/119 Option A2 Water heater piping General piping information Thermal expansion Water hammerBoiler water Water heater wiring Filling the inner domestic water tank A4 Water heater start-upA4 Water heater start-up  General notes A5 Adjusting water heater temperatureSetting the thermostat A5 Adjusting water heater temperature Gold Plus 30/40/60/80 Plus 100/110/119 Plus 40/60/80 Maintenance schedule annual service technician A6 Water heater maintenanceFilling Draining A6 Water heater maintenance Draining inner domestic water tank · Recirculation A7 Recirculation and heat tracing· Self-regulating heat tracing Components Gas-fired boiler applications B1. Install system water pipingExpansion tank and make-up water System water piping methodsBoiler circulator Sizing space heat system pipingZoning with zone valves Install system water piping space heatingZoning with circulators B1 Install system water piping space heatingCombined space heating/water heating applications Install boiler-to-water heater pipingDedicated water heating-only applications For boilers other than Ultra Gas, see page 67 for ratings Installation must comply with B3 Field wiring Gas boilers onlyWiring boiler circulator Wiring water heater circulatorRouting line voltage wiring Wiring a system circulatorOutdoor temperature sensor Water heater thermostatLow voltage field wiring connections B4 Start-up Gas boilers only Follow boiler manual Water heater operation setupSet space heating operation Water heater operationOperating information Verify water heater operationReplace jacket front door Boiler-side piping except Gas Boiler-side piping except Gas  Wiring optionsPrimary/secondary piping 60 Pump relays and 3-way priority valve and priority relay 58 or , page 59 Priority using 2-way valve Tions Applications Multiple water heaters This diagram Special considerations Connecting water heater to steam boilerSteam boiler application Boiler-side wiring & controls except Gas Circulators Boiler-side wiring & controls except Gas Zone Valves Boiler ModelsSystem piping Typical wiringPump zones Primary/secondary piping sys- temsBoiler-side wiring & controls except Gas  Zoning with pumps Using pump relays No domestic priority 39 using 2-way water heater zone valve and no priority valve Zoning with 4-wire zone Valves No domestic priority Zoning with 3-wire zone valves No domestic priority Plus 40/60/80 Boiler-side wiring & controls except Gas  39 using 2-way Water heater zone valve and no priority valve Boiler-side wiring & controls except Gas  Room Thermostat Pump relays Replacement parts Series 3 only Gold Plus 30/40/60/80 or Plus 40/60/80 Replacement parts Weil-McLain Part Description Size ManufacturerPlus 100/110/119 Replacement parts Plus 100/110/119 Series Dimensions PLUS-Line indirect water heaters, Series Water heater dimensionsMBH Water heater performance ratingsWeil-McLain Limited Warranties

PLUS-E017-A/1206 specifications

The Weil-McLain PLUS-E017-A/1206 is a high-performance heating boiler that reflects the brand's commitment to quality engineering and advanced technology. This model is renowned for its efficiency and reliability, making it a preferred choice for both residential and commercial heating applications.

One of the standout features of the PLUS-E017-A/1206 is its exceptional efficiency rating. The boiler employs advanced condensing technology, which allows it to utilize the latent heat in exhaust gases. This means it can achieve efficiency levels of over 90%, significantly reducing energy consumption and lowering utility bills. The unit also complies with stringent regulatory standards, making it an environmentally friendly heating solution.

The PLUS-E017-A/1206's compact design is another significant characteristic, allowing for easy installation even in limited spaces. It is built with durable materials that enhance its longevity and efficiency. The sleek appearance of the unit also makes it suitable for various settings, maintaining aesthetic appeal while delivering powerful heating performance.

This boiler is equipped with advanced controls and a user-friendly interface, offering precise temperature management and efficient operation. The control panel showcases a digital display, enabling easy monitoring of system performance. Additionally, it allows for integration with smart home systems, providing users with enhanced control over their heating systems remotely.

Safety features are paramount in the PLUS-E017-A/1206. It includes multiple safety mechanisms designed to prevent overheating and pressure issues, ensuring worry-free operation. These elements, combined with Weil-McLain’s reputation for durable construction, contribute to the boiler’s overall reliability.

The PLUS-E017-A/1206 is designed with ease of maintenance in mind. It features accessible components that can be easily serviced, minimizing downtime and reducing maintenance costs. With Weil-McLain’s extensive network of support, users can rely on expert assistance when needed.

Overall, the Weil-McLain PLUS-E017-A/1206 is a robust heating solution that combines efficiency, safety, and advanced technology. Its range of features makes it an excellent choice for those seeking a dependable boiler that delivers consistent performance and energy savings. Whether for a home or business, the PLUS-E017-A/1206 represents a smart investment in heating technology.