Weil-McLain PLUS-E017-A/1206 manual Pump relays

Page 60

PLUS LINEIndirect-Fired Water Heaters – Series 3

D Boiler-side wiring & controls (except Gas)continued

Figure 42

Typical wiring:

• Zoning with pumps

• Pump relays

• Domestic priority with 3- way priority valve and priority relay

• Also refer to Weil-McLain Boiler Zone Wiring Guide for further details.

• Refer to Wiring requirements on page 47.

System piping

Apply this wiring to systems in:

• Figure 22, page 38

Notes

1.

These drawings are conceptual only. They show representative piping components and

 

 

layout. Weil-McLain does not represent that the drawings meet any particular mechanical

 

 

or building codes. The installer is responsible for inclusion of all required safety devices, or

 

 

other miscellaneous piping hardware not shown on drawings. The installer is responsible

 

 

for proper sizing/selection of all hardware shown on this diagram.

 

2.

Follow component manufacturer’s instructions for installation of all items shown.

 

3.

See Weil-McLain installation instructions for specific details on installing the boiler.

60

Part Number PLUS-E017-A/1206

Image 60
Contents Plus Line Read this page first Hazard definitionsContents Zoning with pumps Gold Plus 30/40/60/80 or Plus 40/60/80 Plus 100/110/119 Multiple water heater applications A1 Pre-installation CodesGold Plus 30/40/60/80 or Plus 40/60/80 see Figure Plus 100/110/119 see FigureRestrictions Code restrictions National Standard Plumbing CodeUniform Plumbing Code Temperature & pressure T & P relief valve Water heater pipingAir vent A2 Water heater piping  Drain valveGold Plus 30/40/60/80 Or Plus 40/60/80 Option Plus 100/110/119 Option A2 Water heater piping Thermal expansion Water hammer General piping informationBoiler water Water heater wiring A4 Water heater start-up Filling the inner domestic water tankA4 Water heater start-up  A5 Adjusting water heater temperature General notesA5 Adjusting water heater temperature  Setting the thermostatGold Plus 30/40/60/80 Plus 100/110/119 Plus 40/60/80 A6 Water heater maintenance Maintenance schedule annual service technicianA6 Water heater maintenance  Filling DrainingDraining inner domestic water tank A7 Recirculation and heat tracing · Recirculation· Self-regulating heat tracing Components B1. Install system water piping Gas-fired boiler applicationsSystem water piping methods Expansion tank and make-up waterBoiler circulator Sizing space heat system pipingInstall system water piping space heating Zoning with zone valvesB1 Install system water piping space heating Zoning with circulatorsInstall boiler-to-water heater piping Combined space heating/water heating applicationsDedicated water heating-only applications For boilers other than Ultra Gas, see page 67 for ratings B3 Field wiring Gas boilers only Installation must comply withWiring boiler circulator Wiring water heater circulatorWiring a system circulator Routing line voltage wiringOutdoor temperature sensor Water heater thermostatLow voltage field wiring connections Follow boiler manual Water heater operation setup B4 Start-up Gas boilers onlySet space heating operation Water heater operationVerify water heater operation Operating informationReplace jacket front door Boiler-side piping except Gas Wiring options Boiler-side piping except Gas Primary/secondary piping 60 Pump relays and 3-way priority valve and priority relay 58 or , page 59 Priority using 2-way valve Tions Applications Multiple water heaters This diagram Connecting water heater to steam boiler Special considerationsSteam boiler application Boiler-side wiring & controls except Gas Boiler-side wiring & controls except Gas  CirculatorsZone Valves Boiler ModelsTypical wiring System pipingPrimary/secondary piping sys- tems Pump zonesBoiler-side wiring & controls except Gas  Zoning with pumps Using pump relays No domestic priority 39 using 2-way water heater zone valve and no priority valve Zoning with 4-wire zone Valves No domestic priority Zoning with 3-wire zone valves No domestic priority Plus 40/60/80 Boiler-side wiring & controls except Gas  39 using 2-way Water heater zone valve and no priority valve Boiler-side wiring & controls except Gas  Room Thermostat Pump relays Replacement parts Series 3 only Replacement parts  Gold Plus 30/40/60/80 or Plus 40/60/80Description Size Manufacturer Weil-McLain PartPlus 100/110/119 Replacement parts Plus 100/110/119 Series Water heater dimensions Dimensions PLUS-Line indirect water heaters, SeriesWater heater performance ratings MBHWeil-McLain Limited Warranties

PLUS-E017-A/1206 specifications

The Weil-McLain PLUS-E017-A/1206 is a high-performance heating boiler that reflects the brand's commitment to quality engineering and advanced technology. This model is renowned for its efficiency and reliability, making it a preferred choice for both residential and commercial heating applications.

One of the standout features of the PLUS-E017-A/1206 is its exceptional efficiency rating. The boiler employs advanced condensing technology, which allows it to utilize the latent heat in exhaust gases. This means it can achieve efficiency levels of over 90%, significantly reducing energy consumption and lowering utility bills. The unit also complies with stringent regulatory standards, making it an environmentally friendly heating solution.

The PLUS-E017-A/1206's compact design is another significant characteristic, allowing for easy installation even in limited spaces. It is built with durable materials that enhance its longevity and efficiency. The sleek appearance of the unit also makes it suitable for various settings, maintaining aesthetic appeal while delivering powerful heating performance.

This boiler is equipped with advanced controls and a user-friendly interface, offering precise temperature management and efficient operation. The control panel showcases a digital display, enabling easy monitoring of system performance. Additionally, it allows for integration with smart home systems, providing users with enhanced control over their heating systems remotely.

Safety features are paramount in the PLUS-E017-A/1206. It includes multiple safety mechanisms designed to prevent overheating and pressure issues, ensuring worry-free operation. These elements, combined with Weil-McLain’s reputation for durable construction, contribute to the boiler’s overall reliability.

The PLUS-E017-A/1206 is designed with ease of maintenance in mind. It features accessible components that can be easily serviced, minimizing downtime and reducing maintenance costs. With Weil-McLain’s extensive network of support, users can rely on expert assistance when needed.

Overall, the Weil-McLain PLUS-E017-A/1206 is a robust heating solution that combines efficiency, safety, and advanced technology. Its range of features makes it an excellent choice for those seeking a dependable boiler that delivers consistent performance and energy savings. Whether for a home or business, the PLUS-E017-A/1206 represents a smart investment in heating technology.