B. Securing Stove Pipe/Liner to Flue Collar
1.There are 4
2.Attach gasket to bottom side of flue collar with a thin coat of silicone.
| Gasket |
Flue Collar | Stove Pipe/Liner |
Figure 40.1
C. Optional Offset Adapter Installation
In some installations the flue collar and stove pipe/liner do not always align properly. This situation may be remedied by using the optional offset adapter. See Appliance Dimen- sions page for the amount of distance this accessory can telescope between the flue collar and stove pipe/liner.
1.Remove the cast iron flue collar from the appliance and flip it upside down. Using the larger #7 drill bit supplied, drill through all 8 countersunk locations. Figure 40.2.
2.Slide the gasket over the the flue collar and attach it to the offset adapter using the
Figure 40.3.
3.Adjust the offset adapter to desired distance. Drill holes through the lower chamber as shown in Figure 40.4 using the small drill bit #26 provided.
4.Cut the gasket to the proper length and slide in between the upper and lower chambers centered on the screw holes. Attach the upper and lower chambers with screws provided. Figure 40.5.
5.Repeat the process on the bottom side.
Cast Iron Flue Located on Appliance
Drill through all 8 countersunk locations
Figure 40.2
Figure 40.3
Once distance is established, drill holes and secure both chambers together.
Figure 40.4
Figure 40.5
40 | Heatilator • |