Heatiator CB4236IR, CB4842IR For Your Safety Read Before Lighting, Lighting Instructions IPI

Page 10

J. Lighting Instructions (IPI)

For normal use, activate/deactivate your fireplace with the wall switch or remote control.

The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer.

If your fireplace must be deactivated for serviced or an extended period of time, follow the instructions below.

 

FOR YOUR SAFETY READ BEFORE LIGHTING

 

This appliance needs fresh air for safe operation

 

 

and must be installed so there are provisions for

 

 

adequate combustion and ventilation air.

 

 

 

 

WARNING:

If you do not follow these instructions exactly, a fire

 

 

 

 

This appliance must be installed in accordance with

 

 

 

 

 

 

 

 

 

 

 

 

 

or explosion may result causing property damage,

 

 

 

 

local codes, if any; if not, follow ANSI Z223.1 or, in

 

 

 

 

 

personal injury or loss of life.

 

 

 

 

Canada, current CAN/CGA-B149.

 

 

 

 

 

 

 

 

A.

This appliance is equipped with an ignition device which

 

• If you cannot reach your gas supplier, call the fire

 

This appliance must be properly connected to a

 

automatically lights the pilot. Do not try to light the pilot by

 

department.

 

 

 

venting system in accordance with the

 

hand.

 

C.

Use only your hand to push in and move the gas control

 

manufacturer's installation instructions.

B.

BEFORE LIGHTING smell all around the appliance area for

 

 

 

 

 

WARNING: Improper installation,

 

valve or turn the gas control knob. Never use tools. If the

 

 

gas. Be sure to smell next to the floor because some gas is

 

 

 

 

lever or knob will not move by hand, don't try to repair it, call

 

 

heavier than air and will settle on the floor.

 

 

 

 

 

 

a qualified service technician. Force or attempted repair may

 

adjustment, alteration, service or maintenance can

 

WHAT TO DO IF YOU SMELL GAS

 

 

 

 

 

 

result in a fire or explosion.

 

 

 

cause injury or property damage. Refer to the

 

• Do not try to light any appliance.

 

D.

Do not use this appliance if any part has been under water.

 

owner's information manual provided with the

 

• Do not touch any electric switch; do not use any phone in

 

Immediately call a qualified service technician to inspect the

 

appliance. For assistance or additional information

 

your building.

 

 

appliance and to replace any part of the control system and

 

consult a qualified installer, service agency or the

 

• Immediately call your gas supplier from a neighbor's

 

any gas control which has been under water.

 

 

 

gas supplier.

 

phone. Follow the gas supplier's instructions.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: Hot while in operation. Do

 

 

 

 

LIGHTING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

not touch. Keep children, clothing, furniture,

 

 

 

 

 

 

 

 

 

gasoline and other liquids having flammable vapors

 

 

 

 

 

 

 

 

 

1.

STOP! Read the safety information above on this label.

5.

Wait five minutes to clear out any gas. If you then smell gas, STOP!

 

away.

 

WARNING RISK OF FIRE

2.

Turn wall switch to the "OFF" position or thermostat to the

 

Follow "B" in the safety information above on this label. If you don't

 

 

lowest setting.

 

 

smell gas, go to the next step.

 

 

 

3.

Turn off all electric power to the appliance.

 

6.

To turn on the burner, turn on all electric power to this appliance and

 

This appliance is intended to burn a specified gas

4.

This appliance is equipped with an ignition device which

 

turn on the wall switch or set the thermostat to the desired setting.

 

fuel only. Do not attempt to use with solid wood fuel

 

automatically lights the pilot. Do NOT try to light the pilot by

7.

If the appliance will not operate, follow the instructions "TO TURN OFF

 

or another type of fuel. Do not attempt to modify or

 

hand.

 

 

GAS TO APPLIANCE" and call your service technician or gas supplier.

 

use any other type of gas burner system.

 

 

TO TURN OFF GAS TO APPLIANCE

 

 

 

WARNING: Disconnect the electric power

 

 

 

 

 

 

 

 

 

 

before servicing. If for any reason the original wire

 

 

 

 

 

supplied with the appliance must be replaced, it must

 

 

 

 

 

1.

Turn off wall switch or set thermostat to lowest setting.

3.

Push the gas control lever in and move to the "OFF" position

 

be replaced with 105° C or its equivalent.

 

For use with natural gas or propane. A conversion kit

2.

Turn off all electric power to the appliance if service is to be

 

or push the gas control lever to the "OFF" position. Do not

 

 

performed.

 

 

force.

 

 

 

as supplied by the manufacturer shall be used to

 

 

 

 

 

 

4.

Replace the control access panel.

 

 

 

convert this appliance to the alternative fuel.

 

 

 

 

 

 

 

 

 

 

 

 

* Also certified for installation in a bedroom or a

 

 

 

 

 

 

 

 

 

 

 

 

 

bed-sitting room.

 

 

 

 

 

 

 

 

 

 

 

*

For U.S. only!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Due to high surface temperatures, keep children, clothing and furniture away.

 

 

 

 

 

 

 

NATURAL GAS

 

Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.

33631D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

Image 10
Contents Models CB4236IR CB4842IR Vent Gas Appliance Installation and OperationWhat to do if you smell gas Congratulations Homeowner Reference InformationInstaller Guide Table of ContentsUser Guide  a Warranty Hearth & Home Technologies Inc Limited Lifetime WarrantyWarranty This warranty is void ifListing and Code Approvals Operating Instructions Gas Fireplace SafetyYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceFor Your Safety Read Before Lighting Lighting Instructions IPIInitial Break-in Procedure  L. Flame Adjustment ControlFrequently Asked Questions After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase Clearances Width Height Depth Model Rough Opening Rough OpeningMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesVent System Configuration Vent Information and DiagramsVent Guidelines Wall and Ceiling Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Vertical Penetration FramingAppliance Preparation Gas and Electrical ConnectionsInstall Attic Insulation Shield Installing Vent PipeAssembly of Vent Sections Secure Vent SectionsGas Pressure Gas InformationFuel Conversion Gas ConnectionIntellifire Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical Service and RepairJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Glass Assembly Install the Log AssemblyFirescreen Air Shutter Setting Install Louvers and TrimHood Troubleshooting Intellifire Ignition SystemHave accumulated on flame sensing rod Appliance Dimension Diagram Reference Materials B. Service Parts List CB4236IRService Parts List CB4842IRIPI Valve Assembly  C. Optional Components Optional Components Model # DescriptionContact Information