Heatiator CB4842IR, CB4236IR owner manual Have accumulated on flame sensing rod

Page 33

A. Intellifire Ignition System (continued)

4. Pilot lights but continues

A. A shorted or loose connection

Verify all connections to wiring diagram in manual. Verify

to spark, and main burner

in flame sensing rod.

connections underneath pilot assembly are tight. Verify connections

will not ignite. (If the pilot

 

are not grounding out to metal chassis, pilot burner, pilot enclosure

continues to spark after

 

or screen if present, or any other metal object.

the pilot flame has been lit,

 

 

B. Poor flame rectification or

With fixed glass assembly in place, verify that flame is engulfing

flame rectification has not

contaminated flame sensing

flame sensing rod on left side of pilot hood. Flame sensing rod

occurred.)

rod.

should glow shortly after ignition. Verify correct pilot orifice is

 

 

 

installed and gas inlet is set to pressure specifications. Clean flame

 

 

sensing rod with emery cloth to remove any contaminants that may

 

 

have accumulated on flame sensing rod.

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

Verify that wire harness is firmly connected to the module.

 

 

 

 

D. Damaged pilot assembly or

Verify that ceramic insulator around the flame sensing rod is not

 

contaminated flame sensing

cracked, damaged, or loose. Verify connection from flame sensing

 

rod.

rod to white sensor wire. Clean flame sensing rod with emery cloth

 

 

to remove any contaminants that may have accumulated on flame

 

 

sensing rod. Verify continuity with a multimeter with ohms set at

 

 

lowest range. Replace pilot if any damage is detected.

 

 

 

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF rocker switch or wall

 

 

switch in ON position. If there is no spark at “I” terminal module must

 

 

be replaced. If there is a spark at “I” terminal, module is fine.

 

 

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish while in

 

 

B. Improper gas inlet pressure.

Verify with manometer. NG should read 5-14 inches w.c. LP should

operation.

 

read 10-14 inches w.c.

 

 

 

C. Inner vent pipe leaking exhaust

Check venting system for damage. Replace/repair improperly

 

gases back into the system.

assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace glass panel

 

 

assembly.

 

E. Improper vent cap installation.

Check for proper installation and freedom from debris or blockage.

 

 

 

 

F. High limit switch has been

This appliance is equipped with an auto reset high limit switch

 

automatically activated.

which will shut down the appliance if it spills under flue blockage or

 

 

excessive negative pressure conditions. Shut off the appliance and

 

 

the gas supply. Do not attempt to operate the appliance until it has

 

 

been examined by a qualified service technician.

 

 

 

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

33

Image 33
Contents Installation and Operation Models CB4236IR CB4842IR Vent Gas ApplianceWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Installer GuideUser Guide  a Limited Lifetime Warranty Warranty Hearth & Home Technologies IncThis warranty is void if WarrantyListing and Code Approvals Gas Fireplace Safety Operating InstructionsYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceLighting Instructions IPI For Your Safety Read Before LightingFrequently Asked Questions  L. Flame Adjustment ControlInitial Break-in Procedure After Fireplace is LitMaintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase Width Height Depth Model Rough Opening Rough Opening ClearancesMantel and Wall Projections MantelsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsVent Information and Diagrams Vent System ConfigurationVent Guidelines Pipe Clearances to Combustibles Vent Clearances and FramingWall and Ceiling Penetration Framing Vertical Penetration FramingGas and Electrical Connections Appliance PreparationAssembly of Vent Sections Installing Vent PipeInstall Attic Insulation Shield Secure Vent SectionsFuel Conversion Gas InformationGas Pressure Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntellifire Ignition System Wiring Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Install the Log Assembly Glass AssemblyFirescreen Install Louvers and Trim Air Shutter SettingHood Intellifire Ignition System TroubleshootingHave accumulated on flame sensing rod Reference Materials Appliance Dimension DiagramCB4236IR  B. Service Parts ListCB4842IR Service Parts ListIPI Valve Assembly  C. Optional Components Model # Description Optional ComponentsContact Information