Heatiator CB4842IR, CB4236IR owner manual Listing and Code Approvals

Page 7

1 Listing and Code Approvals

A. Appliance Certification

MODELS: CB4236IR, CB4842IR

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Vented Gas Fireplace Heater

STANDARD: ANSI Z21.88b-2008/CSA 2.33b-2008

NOTICE: This installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemental room heat or as a decorative appliance. It should not be fac- tored as primary heat in residential heating calculations.

B. Tempered Glass Specifications

Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectural Testing, Inc. Reports 02-31919.01 and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Section 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.

C. BTU Specifications

Caliber BV Series

CB4236

CB4842

 

IPI

 

Max/Min Input Rate (NG)

30,000/20,000

33,000/22,000

Orifice Size (NG)

.101 in./2.56 mm

.104 in./2.64 mm

Max/Min Input Rate (LP)

29,500/19,500

32,500/20,000

 

 

 

Orifice Size (LP)

.0635 in./1.61 mm

.065 in./1.65 mm

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Check with your local gas utility to determine proper orifice size.

E. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136, Stan- dard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763 shall be considered non-combustible materials.

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ig- nite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

Image 7
Contents Models CB4236IR CB4842IR Vent Gas Appliance Installation and OperationWhat to do if you smell gas Homeowner Reference Information CongratulationsInstaller Guide Table of ContentsUser Guide  a Limited Lifetime Warranty Warranty Hearth & Home Technologies IncThis warranty is void if WarrantyListing and Code Approvals Operating Instructions Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalLighting Instructions IPI For Your Safety Read Before LightingAfter Fireplace is Lit  L. Flame Adjustment ControlFrequently Asked Questions Initial Break-in ProcedureMaintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase Width Height Depth Model Rough Opening Rough Opening ClearancesMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsVent System Configuration Vent Information and DiagramsVent Guidelines Vertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingGas and Electrical Connections Appliance PreparationSecure Vent Sections Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureElectrical Service and Repair Wiring RequirementsOptional Accessories Requirements Intellifire Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Glass Assembly Install the Log AssemblyFirescreen Air Shutter Setting Install Louvers and TrimHood Intellifire Ignition System TroubleshootingHave accumulated on flame sensing rod Reference Materials Appliance Dimension DiagramCB4236IR  B. Service Parts ListCB4842IR Service Parts ListIPI Valve Assembly  C. Optional Components Model # Description Optional ComponentsContact Information