E. Junction Box Installation

If the box is being wired from the OUTSIDE of the appli- ance:

Remove the cover plate located on the outer shell - right side (see Figure 12.2).

Install the supplied Romex™ connector in the cover plate.

Make all necessary wire connections and reattach the cover plate to the outer shell.

If the box is being wired from the INSIDE of the appli- ance:

Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell.

Pull the electrical wires from outside the appliance through this opening into the valve compartment.

Make all necessary wire connections to the junction box/ receptacle and reassemble the junction box/receptacle to the outer shell.

F. Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mounted switch for use with a fan, see Figure 12.3:

The power supply for the appliance must be brought into a switch box.

The power can then be supplied from the switch box to the appliance using a minimum of 14-3 with ground wire.

At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch as shown.

At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as shown.

Add a 1/4 in. insulated female connector to the red (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown.

 

 

 

 

Romex

 

 

 

 

Connector

 

 

 

 

14/2WG

 

 

 

 

Cover Plate

 

 

 

 

outside firebox

T

 

 

 

H

 

 

 

 

W

L

K

 

 

B

 

 

 

 

 

 

 

 

 

T

 

K

 

 

H

 

 

 

W

 

L

 

 

 

B

 

Copper

 

 

 

 

 

 

 

 

 

 

GRN wire

ground attached

 

 

 

to GRN screw with

 

 

 

inside box

 

 

 

GRN wire

 

 

 

 

 

 

 

NOTICE: DO NOT wire

 

 

 

110 VAC to wall switch.

Figure 12.2 Junction Box Detail

 

 

 

 

 

Switch

Minimum 14-3 AWG with Ground

 

 

 

 

 

 

Red

 

 

 

 

 

Black

 

 

 

 

 

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

White

 

Junction Box

 

 

 

 

Green

 

 

 

 

 

 

Green

 

 

 

Red

Black

White

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Switch Box Supply

Wires

Knockout

Red

Figure 12.3 Junction Box Wired to Wall Switch or BC10

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

27

Image 27
Contents Installation and Operation Models CB4236IR CB4842IR Vent Gas ApplianceWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Installer GuideUser Guide  a Limited Lifetime Warranty Warranty Hearth & Home Technologies IncThis warranty is void if WarrantyListing and Code Approvals Gas Fireplace Safety Operating InstructionsYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalLighting Instructions IPI For Your Safety Read Before LightingAfter Fireplace is Lit  L. Flame Adjustment ControlFrequently Asked Questions Initial Break-in ProcedureMaintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase Width Height Depth Model Rough Opening Rough Opening ClearancesMantel and Wall Projections MantelsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsVent Information and Diagrams Vent System ConfigurationVent Guidelines Vertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingGas and Electrical Connections Appliance PreparationSecure Vent Sections Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureElectrical Service and Repair Wiring RequirementsOptional Accessories Requirements Intellifire Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Install the Log Assembly Glass AssemblyFirescreen Install Louvers and Trim Air Shutter SettingHood Intellifire Ignition System TroubleshootingHave accumulated on flame sensing rod Reference Materials Appliance Dimension DiagramCB4236IR  B. Service Parts ListCB4842IR Service Parts ListIPI Valve Assembly  C. Optional Components Model # Description Optional ComponentsContact Information