Heatiator CB4842IR, CB4236IR Fan Kit optional, Clear Space, Decorative Doors and Fronts

Page 9

C. Fan Kit (optional)

Refer to Figure 2.1 for location of control.

D.Clear Space

WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High tempera- tures may start a fire. See Figure 2.2.

Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects.

 

Clear Space

 

3 ft (0.91 m)

 

in front of

 

appliance

Figure 2.2

Clear Space

E. Decorative Doors and Fronts

WARNING! Risk of Fire! Install ONLY doors or fronts approved by Hearth & Home Technologies. Unapproved doors or fronts may cause fireplace to overheat.

This fireplace has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the fireplace with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

For more information refer to the instructions supplied with your decorative door or front.

F. Fixed Glass Assembly

See Section 14.J.

G. Remote Controls, Wall Controls and Wall Switches

Follow the instructions supplied with the control installed to operate your fireplace:

For safety:

Install a switch lock or a wall/remote control with child protection lockout feature.

Keep remote controls out of reach of children.

See your dealer if you have questions.

H. Outside Air (optional)

The outside air kit supplies some fresh combustion air for your fireplace. It may help reduce the effects of negative air pressure. (See Section 9.A.)

Refer to Figure 2.1 for location of control.

Close the inlet to prevent cold drafts when the fireplace is not being used.

CAUTION! Risk of Burns! The outside air control handle is HOT when fireplace is in operation. Adjust BEFORE lighting fire.

I. Before Lighting Fireplace

Before operating this fireplace for the first time, have a qualified service technician:

Verify all shipping materials have been removed from inside and/or underneath the firebox.

Review proper placement of logs, ember material and/or other decorative materials.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position and that the integral barrier is in place.

WARNING! Risk of Fire/Asphyxiation! DO NOT operate fireplace with fixed glass assembly removed.

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

Image 9
Contents Installation and Operation Models CB4236IR CB4842IR Vent Gas ApplianceWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Installer GuideUser Guide  a Limited Lifetime Warranty Warranty Hearth & Home Technologies IncThis warranty is void if WarrantyListing and Code Approvals Gas Fireplace Safety Operating InstructionsYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceLighting Instructions IPI For Your Safety Read Before LightingFrequently Asked Questions  L. Flame Adjustment ControlInitial Break-in Procedure After Fireplace is LitMaintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase Width Height Depth Model Rough Opening Rough Opening ClearancesMantel and Wall Projections MantelsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsVent Information and Diagrams Vent System ConfigurationVent Guidelines Pipe Clearances to Combustibles Vent Clearances and FramingWall and Ceiling Penetration Framing Vertical Penetration FramingGas and Electrical Connections Appliance PreparationAssembly of Vent Sections Installing Vent PipeInstall Attic Insulation Shield Secure Vent SectionsFuel Conversion Gas InformationGas Pressure Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntellifire Ignition System Wiring Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Install the Log Assembly Glass AssemblyFirescreen Install Louvers and Trim Air Shutter SettingHood Intellifire Ignition System TroubleshootingHave accumulated on flame sensing rod Reference Materials Appliance Dimension DiagramCB4236IR  B. Service Parts ListCB4842IR Service Parts ListIPI Valve Assembly  C. Optional Components Model # Description Optional ComponentsContact Information