Heatiator BCDV36 manual Appliance Preparation, Log Set, Placing the Vermiculite and Lava Rock

Page 18

BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS

J. APPLIANCE PREPARATION

1. LOG SET

The log set should look similar to that in Figure 30.

Figure 30

BCDV36 Gas Log Set

2.PLACING THE VERMICULITE AND LAVA ROCK

See Figure 31.

3. PLACING THE ROCK WOOL

Place a small amount of 1/2” diameter pieces (dime sized) of rock wool on the ember tray above the burner

WARNING!

RISK OF CARBON MONOXIDE!

Never operate this appliance with the glass removed or not sealed.

WARNING!

RISK OF CARBON MONOXIDE!

Do not hit or strike the glass. Do not operate this ap- pliance if the glass if broken or cracked.

Figure 31

Placing the Rock Wool

(top logs removed for clarity)

tube. This will provide a glowing ember look to the appliance when burning. See Figure 31.

4. GLASS AND SCREEN REPLACEMENT

See page 22 of this manual.

33606 Rev D

18

01-03

Image 18
Contents Installation & Operating Instructions Please retain this manual for future reference S. and Canada Certification Appliance SpecificationsGlass CERTIFICATIONS/SPECIFICATIONS Local CodesBuilders Choice Series Installation Instructions Nomenclature Builders Choice NomenclatureCatalog # Description Location and Clearances Appliance Locations and Space RequirementsClearances Setting the Appliance Wear gloves and safety glasses for protectionFraming Horizontal Termination Installing the Interior Wall ShieldVenting TerminationOne 45 Elbow Two Elbows No ElbowsRear Vented Appliances 45 Elbow Two Elbows Three Elbows One Elbow HorizontalDimension Descriptions Termination Cap LocationsVent Clearances Vent Lengths Vertical TerminationClearances Vent SupportFirestop Spacer/Chimney Installation Installing the Firestop Spacer Roof Pitch Min. FtChimney Height Chase/Termination Installation Attaching the Venting to the Appliance Assembling Minimum Installations MI SectionsAssembling Vent Sections Assembling Vent SectionsAssembling Slip Sections Disassembling Vent Sections only if NecessaryGAS Pressure UtilitiesGAS Line Connection GAS ConversionsWall Switch WiringJunction BOX Installation and Wiring Standing Pilot Ignition Wiring DiagramFinishing LOG SET Glass and Screen ReplacementAppliance Preparation Placing the Vermiculite and Lava RockLighting Instructions Do not light by handSeasonal Checklist Prior to OperationStanding Pilot Operation START-UP Issues Maintenance InstructionsFuel Conversion Cleaning the Glass LOG REMOVAL/REPLACEMENTGlass Cleaning Optional Components Fan KitReplacement Parts BCDV36 Gas Log AssemblyHOMEOWNER’S Notes HOMEOWNER’S Notes Index How to Obtain Service Limited Lifetime WarrantyYear Limited Warranty Conditions, Exclusions, & Limitations of Liability