Heatiator BCDV36 manual Venting, Horizontal Termination, Installing the Interior Wall Shield

Page 8

BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS

F. VENTING

WARNING - RISK OF FIRE!

Air space clearances must be maintained at all times.

WARNING - RISK OF FIRE!

The horizontal run of vent must have a 1/4” rise for every 1 ft. of run towards the termination. Never al- low the vent to run downward. This could cause high temperatures and may present a fire hazard.

Use only pipe supplied and listed for use with this appli- ance. See page 5 for a description of the listed compo- nents. See the directions on page 13 for assembling vent sections.

1.HORIZONTAL TERMINATION

a.Installing the Interior Wall Shield

Frame a hole in a combustible wall for an interior wall shield as shown in Figure 5. This shield maintains minimum clearances and prevents cold air infiltration.

b.Termination

Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap.

Install the cap as shown in Figure 6. The cap pipe sections should overlap the vent pipe by 1-1/2”. Caulk the outside edges of the cap.

Local codes may require the installation of a shield (product #CS) which prevents the cap from accidentally touching anything or anyone.

Figure 11 illustrates cap locations prescribed by current ANSI Z273.1 and CAN/CGA-B149 Installation Codes.

The termination cap height must meet all local and national codes and not be easily blocked or obstructed. If the hole being penetrated is of noncombustible materials, a 9” diameter hole is acceptable.

CAUTION:

Provisions shall be made to provide adequate com- bustion and ventilation air.

WARNING - RISK OF FIRE!

If you have chosen horizontal termination, be sure there are no present nor future obstructions from trees, bushes, snow drifts, etc.

Figure 5

Interior Wall Shield

Figure 6

Venting Through the Wall

33606 Rev D

8

01-03

Image 8
Contents Installation & Operating Instructions Please retain this manual for future reference Appliance Specifications Glass CERTIFICATIONS/SPECIFICATIONSS. and Canada Certification Local CodesBuilders Choice Series Installation Instructions Catalog # Description NomenclatureBuilders Choice Nomenclature Clearances Location and ClearancesAppliance Locations and Space Requirements Framing Setting the ApplianceWear gloves and safety glasses for protection Installing the Interior Wall Shield VentingHorizontal Termination TerminationNo Elbows Rear Vented Appliances 45 ElbowOne 45 Elbow Two Elbows Two Elbows Three Elbows One Elbow HorizontalDimension Descriptions Termination Cap LocationsVertical Termination ClearancesVent Clearances Vent Lengths Vent SupportChimney Height Chase/Termination Installation Firestop Spacer/Chimney InstallationInstalling the Firestop Spacer Roof Pitch Min. Ft Assembling Minimum Installations MI Sections Assembling Vent SectionsAttaching the Venting to the Appliance Assembling Vent SectionsAssembling Slip Sections Disassembling Vent Sections only if NecessaryUtilities GAS Line ConnectionGAS Pressure GAS ConversionsWiring Junction BOX Installation and WiringWall Switch Standing Pilot Ignition Wiring DiagramFinishing Glass and Screen Replacement Appliance PreparationLOG SET Placing the Vermiculite and Lava RockLighting Instructions Do not light by handStanding Pilot Operation Seasonal ChecklistPrior to Operation Fuel Conversion START-UP IssuesMaintenance Instructions Glass Cleaning Cleaning the GlassLOG REMOVAL/REPLACEMENT Optional Components Fan KitReplacement Parts BCDV36 Gas Log AssemblyHOMEOWNER’S Notes HOMEOWNER’S Notes Index Limited Lifetime Warranty Year Limited WarrantyHow to Obtain Service Conditions, Exclusions, & Limitations of Liability