Heatiator C40 owner manual Manual Timer Override, Burn Rates, Burning Guidelines, Opacity

Page 16

P. Manual Timer Override

If timer is unintentionally engaged, push the Timer Over- ride Lever to the left. This will disengage the timer and set the Fireplace back to the low setting. Figure 2.6

Manual Override

Left-Close Right-Open

Figure 2.6 Manual Override

R. Burn Rates

HIGH - Maximum Heat: Fully open (Combustin Air Control all the way to the right). It is important to do this when reload- ing the fireplace. Failure to do this could result in excessive emissions (smoke).

MEDIUM HIGH BURN RATE - 15,000 to 30,000 BTU: After a wood load has been burning on high for 5 to 15 minutes, close the Combustion Air Control to 1/2 in. - 1-1/2 in. (13 mm-38 mm) distance open. (Move the handle to left to stop and then to right for the proper setting).

MEDIUM - 10,000 - 15,000 BTU: After a wood load has been burning on high for 5 to 15 minutes (longer for very large pieces or wet wood), Combustion Air Control left to 1/8 in. -1/2 in. (3 mm-13 mm) distance open. (Move the handle to left to stop and then to right for the proper setting).

LOW - Below 10,000 BTU: After a wood load has been burn- ing on high for 5 to 15 minutes (longer for very large pieces or wet wood), gradually slide the Combustion Air Control left to close down the air, making sure to maintain flames in the fireplace. It is very important to maintain flames in your fireplace during the first few hours of a low burn to avoid excessive air pollution.

Q. Burning Guidelines

For maximum operating efficiency with the lowest emissions, follow these operating procedures:

1.Regardless of desired heat output, when loading the fireplace, burn your fireplace with the Combustion Air

Control wide open (fully to the right) for a minimum of 5 to 15 minutes.

2.Regulate burn rate (heat output) by using the Com- bustion Air Control. See Figure 2.5 on page 15.

3.Heat output settings: Follow the burn rate instructions listed below.

Burn Rate

BTU / Hr

*Combustion Air Control

Low

Below 10,000

Slide LEFT to Stop

Medium

10,000 - 15,000

Stop to 1/8 in. -1/2 in. open

Medium High

15,000 - 30,000

Stop to 1/2 in. - 1-1/2 in. open

High

Maximum Heat

All the way to RIGHT

 

 

 

*These are approximate settings, and will vary with type of wood or chimney draft.

S. Opacity

This is the measure of how cleanly your fireplace is burning. Opacity is measured in percent; 100% opacity is when an ob- ject is totally obscured by the smoke column from a chimney, and 0% opacity means that no smoke column can be seen. As you become familiar with your fireplace, you should peri- odically check the opacity. This will allow you to know how to burn your fireplace as nearly smoke-free as possible (goal of 0% opacity).

Page 16

Heatilator • Constitution EPA Fireplace • 480-1091D

4/20/11

Image 16
Contents C40 Hot screen/mesh and glass doors will cause burnsListing Label Information/Location 009Safety Alert Key Table Of Contents Limited Lifetime Warranty Warranty Conditions Appliance Certification Listing and Code ApprovalsManufactured Home Approved BTU & Efficiency Specifications Electrical Codes Glass SpecificationsNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsUser GuideHot glass will cause burns Firebrick Placement Baffle and Blanket PlacementGeneral Information Moisture content Wood FuelHardwood vs. Softwood SeasoningSeasoned Wood Outside AirStoring Wood Clear Space Near the Fireplace Glass DoorsFire Safety Symptoms of Over-FiringOver-Firing Your Appliance Chimney FireStarting a Fire Burning ProcessKindling or 1st stage 2nd stageFinal stage Automatic Combustion Control ACCSlide Air Control Slide Left to Stop Manual Timer Override Burn RatesBurning Guidelines OpacityUnderstanding Vent Problems TroubleshootingDraft Problems Factory-built Fireplaces Troubleshooting Diagnostics and Problem Solving Diagnostic Question Possible Causes of Condition SolutionsDon’t get enough/any heat. What can I do about it? Maintenance and Servicing the Fireplace General Maintenance Creosote Chimney CleaningCare and Cleaning of Plated Surfaces Glass CleaningDisposal of Ashes Door and Door GasketMaintenance Task List Replacement Maintenance Glass ReplacementFirebrick Replacement Fire Brick ConfigurationsFan Replacement Baffle Removal and InstallationFan Cord Location Fan Replacement Instructions Removing the fanTimer Assembly Replacement 11 Timer AssemblyTimer Removal & Replacement Linkage Arm Slider Control Rod20/11 Heatilator Constitution EPA Fireplace 480-1091D Service & Maintenance Log Date of Service Performed By Description of ServiceGetting Started Installer Guide Typical Fireplace SystemDraft Design and Installation ConsiderationsNegative Pressure Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsFireplace System Requirements Tools and Supplies NeededInspect Fireplace and Components Framing & Clearances Selecting Fireplace LocationsClearances Clearances to Combustible MaterialsFrame the Fireplace Optional Framing Construction / Reduced Mantel HeightElectrical Access and Wiring Diagram Fan Wiring DiagramInstallation of Fireplace Mm metal flex Fireplace Or rigid pipe Secure the Fireplace Place Protective Metal Hearth StripsChimney Assembly Chimney Requirements Chimney Termination RequirementsUsing Offsets/ Returns ExampleInstalling CAK4A and Flex Pipe Assemble the Chimney SectionsInstall Ceiling Firestops Installing Flex PipeInstall Attic Insulation Shield Secure the ChimneyDouble-check the Chimney Assembly Complete InstallationInstall Flashing Cut out Hole in Roof13 Multiple Chimney Locations SL-300 Series Ceiling/Roof Thimble Consult local codes for framing detailsChase Installations Construct the ChaseInstall Chase Top Install Fireplace & ChimneyInstall Termination Cap ST375 Square Termination Cap TCT375 Terra Cotta Cap Hearth Extension Finishing= 1/k x inches of thickness Raised Hearth Extension Framing Fireplace and Hearth Extension are flush on the floorPosition the Hearth Extension Finishing MaterialCombustible Material Non-Combustible MaterialNon-Combustible Sealant Material MantelCardboard or Metal Template Non-Combustible Facing Material Installa Tion 13 Complete installationAccessories Heat Zone Kit OptionalRun Length Cut Pipe 40 ft 6-12m 4 wall Firescreen Reference Materials Fireplace DimensionsConstitution Chimney Components Catalog Description Catalog No15-3/4 DTO134 Service Parts Part number list on following#3 Brick Set StockedDoor Handle Assembly Side viewThis page intentionally left blank Contact Information Do not Discard this Manual
Related manuals
Manual 71 pages 48.08 Kb

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.