Heatiator C40 owner manual Listing Label Information/Location, 009

Page 2

Read this manual before installing or operating this appliance.

Please retain this owner’s manual for future references.

Congratulations

Congratulations on selecting a Heatilator wood burning fireplace. The Heatilator fireplace you have selected is designed to provide the utmost in safety, reliability, and efficiency.

As the owner of a new fireplace, you'll want to read and carefully follow all of the instructions contained in this Owner's Manual. Pay special attention to all Cautions and Warnings.

This Owner's Manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.

Your new Heatilator wood burning fireplace will give you years of durable use and trouble-free enjoyment. Welcome to the Heatilator family of fireplace products!

Homeowner Reference Information

We recommend that you record the following pertinent information about your appliance.

Model Name: ___________________________________________ Date purchased/installed:__________________

Serial Number:__________________________________________ Location on appliance: ____________________

Dealership purchased from: _______________________________ Dealer Phone: __________________________

Notes: _______________________________________________________________________________________

_____________________________________________________________________________________________

Listing Label Information/Location

The model information regarding your specific appliance can be found on the rating plate usually located in the control area of the appliance.

Tested and

O-T L

Portland

Listed by

Oregon USA

CUS

OMNI-Test Laboratories, Inc.

OMNI-Test Laboratories, Inc.

Report #061-S-40-2

TESTED TO

UL 127, ULC-S610-M87

A division of Hearth & Home Technologies Inc. 1915 W. Saunders, Mt. Pleasant, IA 52641

www.heatilator.com

Model:

CONSTITUTION

EPA CERTIFIED F IREPLACE

Serial No / Numéro De Série

009

LISTED FIREPLACE, SOLID FUEL TYPE, ALSO SUITABLE FOR MANUFACTURED HOME INSTALLATION. (UM) 84 HUD. "For Use with Solid Wood Fuel Only."

Install and use only in accordance with manufacturer's installation, venting and operating instructions. Any area incorporating warm or cold air ducts shall be enclosed in accordance with the manufacturer's installation instructions.

Contact Your Local Building Or Fire Officials Or Authority Having Jurisdiction About Restrictions, Installation Inspection And Permits Required In Your Area.

WARNING - For Manufactured Homes: Do not install in a sleeping room. An outside combustion air inlet must be provided and unrestricted while unit is in use. The structural integrity of the manufactured home floor, ceiling and walls must be maintained. The fireplace needs to be properly grounded to the frame of the manfactured home.

Components required for installation: HTI SLSeries Pipe, Termination Cap, Hearth Extension and required accessory Chimney Air Kit Part CAK4A.

Do not connect this unit to a chimney serving another appliance.

DANGER: Risk of electrical shock. Disconnect power supply before servicing.

Electrical Rating: 115 VAC <3.0 AMPS 60 Hz

Do not use grate or elevate fire. Build wood fire directly on firebrick.

Do not overfire. If heater or chimney connector glows, you are overfiring.

Do not use a fireplace insert or other products not specified for use with this product.

WARNING - THIS FIREPLACE HAS NOT BEEN TESTEDUSAWITH N UNVENTED G S LOG SET OR ANY LOG SET.

TO REDUCE RISK OF FIRE OR INJURY, DO NOT IN TALL AN UNVENTED G LOG SET OR ANY LOG SET INTO FIREPLACE.

Must provide a source of air to prevent air starvation from combustion which could result of high levels of carbon monoxide.

Replace glass only with 5mm ceramic available from your dealer.

Optional Fire Screen Part Mesh-EPA, may be used ONLY in

Minimum Clearances To Combustible Material

Chimney sections at any level require a 2” (51mm) minimum air space clearance between the framing and chimney section.

WITHIN NCLOSURE AREA

 

Appliance to backwall

1" (25mm)

Appliance to sidewall

1" (25mm)

Duct boots to framing

0" (0mm)

Top standoffs to header

0" (0mm")

EXPOSED SURFACES

 

Faceplate to sidewall

16" (406mm)

Remote outlet air grills to ceiling

12"(305mm)

MANTEL

 

Mantel from base of fireplace

60" (1524mm)

Maximum mantel depth

12" (305mm)

FLOOR PROTECTION

Combustible flooring 20" (508mm) in front of and 8" (203mm) to either side of the fuel opening must be insulated with non-combustible floor protection with a minimum thickness of 1" (25mm) and ("k" value = 0.43).

In Canada: The hearth extension must be installed according to the installation instructions.

U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to comply with July 1990 particulate emission standards.

 

2011 2012 2013

Jan Feb

Mar Apr May June July Aug Sept Oct. Nov. Dec.

Mfg by:

 

 

 

 

www.heatilator.com

DO NOT REMOVE THIS LABEL

Made in U.S.A

480-1110

 

Page 2

Heatilator • Constitution EPA Fireplace • 480-1091D

4/20/11

Image 2
Contents C40 Hot screen/mesh and glass doors will cause burnsListing Label Information/Location 009Safety Alert Key Table Of Contents Limited Lifetime Warranty Warranty Conditions Manufactured Home Approved Listing and Code ApprovalsAppliance Certification Non-Combustible Materials BTU & Efficiency Specifications Electrical CodesGlass Specifications Combustible MaterialsHot glass will cause burns Operating InstructionsUser GuideYour Fireplace General Information Baffle and Blanket PlacementFirebrick Placement Hardwood vs. Softwood Moisture contentWood Fuel SeasoningStoring Wood Outside AirSeasoned Wood Clear Space Near the Fireplace Glass DoorsOver-Firing Your Appliance Fire SafetySymptoms of Over-Firing Chimney FireKindling or 1st stage Starting a FireBurning Process 2nd stageSlide Air Control Slide Left to Stop Automatic Combustion Control ACCFinal stage Burning Guidelines Manual Timer OverrideBurn Rates OpacityDraft Problems TroubleshootingUnderstanding Vent Problems Factory-built Fireplaces Troubleshooting Diagnostics and Problem Solving Diagnostic Question Possible Causes of Condition SolutionsDon’t get enough/any heat. What can I do about it? Maintenance and Servicing the Fireplace General Maintenance Creosote Chimney CleaningDisposal of Ashes Care and Cleaning of Plated SurfacesGlass Cleaning Door and Door GasketMaintenance Task List Replacement Maintenance Glass ReplacementFirebrick Replacement Fire Brick ConfigurationsFan Cord Location Baffle Removal and InstallationFan Replacement Fan Replacement Instructions Removing the fanTimer Assembly Replacement 11 Timer AssemblyTimer Removal & Replacement Linkage Arm Slider Control Rod20/11 Heatilator Constitution EPA Fireplace 480-1091D Service & Maintenance Log Date of Service Performed By Description of ServiceGetting Started Installer Guide Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Framing & Clearances Selecting Fireplace LocationsClearances Clearances to Combustible MaterialsFrame the Fireplace Optional Framing Construction / Reduced Mantel HeightElectrical Access and Wiring Diagram Fan Wiring DiagramInstallation of Fireplace Mm metal flex Fireplace Or rigid pipe Secure the Fireplace Place Protective Metal Hearth StripsChimney Assembly Chimney Requirements Chimney Termination RequirementsUsing Offsets/ Returns ExampleInstalling CAK4A and Flex Pipe Assemble the Chimney SectionsInstall Ceiling Firestops Installing Flex PipeInstall Attic Insulation Shield Secure the ChimneyInstall Flashing Double-check the Chimney AssemblyComplete Installation Cut out Hole in Roof13 Multiple Chimney Locations SL-300 Series Ceiling/Roof Thimble Consult local codes for framing detailsChase Installations Construct the ChaseInstall Termination Cap Install Fireplace & ChimneyInstall Chase Top ST375 Square Termination Cap TCT375 Terra Cotta Cap = 1/k x inches of thickness FinishingHearth Extension Raised Hearth Extension Framing Fireplace and Hearth Extension are flush on the floorCombustible Material Position the Hearth ExtensionFinishing Material Non-Combustible MaterialCardboard or Metal Template MantelNon-Combustible Sealant Material Non-Combustible Facing Material Installa Tion 13 Complete installationAccessories Heat Zone Kit OptionalRun Length Cut Pipe 40 ft 6-12m 4 wall Firescreen Constitution Fireplace DimensionsReference Materials Chimney Components Catalog Description Catalog No15-3/4 DTO134 Service Parts Part number list on following#3 Brick Set StockedDoor Handle Assembly Side viewThis page intentionally left blank Contact Information Do not Discard this Manual
Related manuals
Manual 71 pages 48.08 Kb

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.