Heatiator C40 owner manual Install Attic Insulation Shield, Secure the Chimney

Page 47

G. Install Attic Insulation Shield

Warning! Risk of Fire! You MUST install an attic insu- lation shield when there is any possibility of insulation or other combustible material coming into contact with the chimney.

Do NOT pack insulation between the chimney and the attic insulation shield.

Failure to keep insulation and other materials away from chimney pipe could cause fire.

Do NOT offset chimney inside insulation shield.

Installation of a ceiling firestop is required

Refer to Figures 8.8 - 8.10.

Roll the shield (around the chimney if already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on top).

Insert three screws into the matching holes to form a tube.

Bend three tabs on the bottom of the tube inward to 90° to maintain chimney air space (refer to Figure 8.8).

Rest the insulation shield on the ceiling firestop below.

Bend the three short tabs at the top of the shield inward to 90° to maintain the 2 in. (51 mm) air space from the chimney.

Bend the remaining top tabs to just meet the pipe.

If you wish to make a custom shield or barrier, follow these guidelines:

Metal is preferred, although any material stiff enough to hold back the insulation can be used.

Warning! Risk of Fire! Use of cardboard or other materials that can deflect under humidity or other envi- ronmental conditions is not recommended.

The shield or barrier must be tall enough to extend above the insulation and prevent blown-in insulation from spilling into the cavity.

Maintain specified air spaces around chimney.

Check instructions and local codes for further details.

H. Secure the Chimney

When offsets and returns are joined to straight pipe sec- tions, they must be locked into position with the screws pro- vided* (outer only), using the predrilled holes. To prevent gravity from pulling the chimney sections apart, the returns and the chimney stabilizers have hanger straps for secur- ing these parts to joists or rafters. See Figure 8.11 on page 48.

*Use #6 or #8 sheet metal screw, or larger, no longer than

1/2 in. (13mm).

 

 

 

 

Bend remaining tabs

 

 

 

 

to rest against pipe to

Bend

 

inward

prevent insulation

90°

 

from falling in.

 

 

 

 

 

Insert three

 

 

 

 

screws

 

3 in. (76 mm)

 

 

overlap

Figure 8.8 Prepare Attic Insulation Shield

 

 

Tabs bent in to

 

Pipe

rest against pipe

 

 

 

 

Attic Insulation Shield

 

 

14-1/2 in. (368 mm)

 

6 Tabs bent

diameter

 

in 90°

Ceiling Firestop

 

 

Insulation

Pipe

Insulation

10-1/2 in.

 

 

(267 mm)

 

 

Figure 8.9 Install Attic Insulation Shield (firestop above ceiling)

 

 

Tabs bent in to

 

 

rest against pipe

 

Pipe

 

 

 

Attic Insulation Shield

 

 

14-1/2 in. (368 mm)

 

 

diameter

 

6 Tabs bent

 

 

in 90°

 

Insulation

 

Insulation

10-1/2 in.

Pipe

Ceiling Firestop

(267 mm)

 

 

Figure 8.10 Install Attic Insulation Shield (firestop below ceiling)

4/20/11

Heatilator • Constitution EPA Fireplace • 480-1091D

Page 47

Image 47
Contents Hot screen/mesh and glass doors will cause burns C40009 Listing Label Information/LocationSafety Alert Key Table Of Contents Limited Lifetime Warranty Warranty Conditions Manufactured Home Approved Listing and Code ApprovalsAppliance Certification Combustible Materials BTU & Efficiency Specifications Electrical CodesGlass Specifications Non-Combustible MaterialsHot glass will cause burns Operating InstructionsUser GuideYour Fireplace General Information Baffle and Blanket PlacementFirebrick Placement Seasoning Moisture contentWood Fuel Hardwood vs. SoftwoodStoring Wood Outside AirSeasoned Wood Glass Doors Clear Space Near the FireplaceChimney Fire Fire SafetySymptoms of Over-Firing Over-Firing Your Appliance2nd stage Starting a FireBurning Process Kindling or 1st stageSlide Air Control Slide Left to Stop Automatic Combustion Control ACCFinal stage Opacity Manual Timer OverrideBurn Rates Burning GuidelinesDraft Problems TroubleshootingUnderstanding Vent Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? General Maintenance Creosote Chimney Cleaning Maintenance and Servicing the FireplaceDoor and Door Gasket Care and Cleaning of Plated SurfacesGlass Cleaning Disposal of AshesReplacement Maintenance Glass Replacement Maintenance Task ListFire Brick Configurations Firebrick ReplacementFan Cord Location Baffle Removal and InstallationFan Replacement Removing the fan Fan Replacement Instructions11 Timer Assembly Timer Assembly ReplacementLinkage Arm Slider Control Rod Timer Removal & Replacement20/11 Heatilator Constitution EPA Fireplace 480-1091D Date of Service Performed By Description of Service Service & Maintenance LogTypical Fireplace System Getting Started Installer GuideNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Selecting Fireplace Locations Framing & ClearancesClearances to Combustible Materials ClearancesOptional Framing Construction / Reduced Mantel Height Frame the FireplaceFan Wiring Diagram Electrical Access and Wiring DiagramInstallation of Fireplace Mm metal flex Fireplace Or rigid pipe Place Protective Metal Hearth Strips Secure the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ ReturnsAssemble the Chimney Sections Installing CAK4A and Flex PipeInstalling Flex Pipe Install Ceiling FirestopsSecure the Chimney Install Attic Insulation ShieldCut out Hole in Roof Double-check the Chimney AssemblyComplete Installation Install Flashing13 Multiple Chimney Locations Consult local codes for framing details SL-300 Series Ceiling/Roof ThimbleConstruct the Chase Chase InstallationsInstall Termination Cap Install Fireplace & ChimneyInstall Chase Top ST375 Square Termination Cap TCT375 Terra Cotta Cap = 1/k x inches of thickness FinishingHearth Extension Fireplace and Hearth Extension are flush on the floor Raised Hearth Extension FramingNon-Combustible Material Position the Hearth ExtensionFinishing Material Combustible MaterialCardboard or Metal Template MantelNon-Combustible Sealant Material 13 Complete installation Non-Combustible Facing Material Installa TionHeat Zone Kit Optional AccessoriesRun Length Cut Pipe 40 ft 6-12m 4 wall Firescreen Constitution Fireplace DimensionsReference Materials Catalog Description Catalog No Chimney Components15-3/4 DTO134 Part number list on following Service PartsStocked #3 Brick SetSide view Door Handle AssemblyThis page intentionally left blank Do not Discard this Manual Contact Information
Related manuals
Manual 71 pages 48.08 Kb

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.