Heatiator C40 owner manual Framing & Clearances, Selecting Fireplace Locations

Page 35

6 Framing & Clearances

A. Selecting Fireplace Locations

Several options are available to you when choosing a loca- tion for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 6.1

Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the fire- place when no outside air is used. Outside air must be used for combustion. The Constitution comes equipped with an outside air inlet to feed combustion air from outside the home, along with an outside air termination cap. Consider- ation should be given to these factors before deciding on a location. See Sections 4 and 5.

NOTICE: In addition to these framing dimensions, also reference the following sections

• Clearances (Section 6.B)

NOTICE:

Illustrations and photos reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation/appearance may vary due to individual design preference.

Hearth & Home Technologies reserves the right to alter its products.

NOTICE:

A minimum 1 in. air clearance must be maintained at the back and to the sides of the fireplace as- sembly.

Chimney sections at any level require a 2 in. mini- mum air space clearance between the framing and chimney sections.

D

E

A

Across a corner

 

C

F

24 in.

(610mm)

 

As a

room H A divider

48 in.

(1219mm)

B

G

A

In an exterior chase or projecting into a garage

Along a wall

I

A

24 in.

(610mm)

B

B

24 in.

(610mm)

Model:

 

A

B

C

D

E

F

G

H

I

Constitution

 

 

 

 

 

 

 

 

 

 

in.

41-7/8

16

89-1/2

63-5/16

22-7/16

44-3/4

14-1/16

55-15/16

50-7/8

(Dimensions for

 

1063

406

2273

1608

570

1137

357

1421

1292

finished walls)

mm

NOTICE: Measurements are FRAMING dimensions only and do not include drywall either in the cavity or on

the interior walls.

Figure 6.1 Fireplace Locations

4/20/11

Heatilator • Constitution EPA Fireplace • 480-1091D

Page 35

Image 35
Contents Hot screen/mesh and glass doors will cause burns C40009 Listing Label Information/LocationSafety Alert Key Table Of Contents Limited Lifetime Warranty Warranty Conditions Manufactured Home Approved Listing and Code ApprovalsAppliance Certification Combustible Materials BTU & Efficiency Specifications Electrical CodesGlass Specifications Non-Combustible MaterialsHot glass will cause burns Operating InstructionsUser GuideYour Fireplace General Information Baffle and Blanket PlacementFirebrick Placement Seasoning Moisture contentWood Fuel Hardwood vs. SoftwoodStoring Wood Outside AirSeasoned Wood Glass Doors Clear Space Near the FireplaceChimney Fire Fire SafetySymptoms of Over-Firing Over-Firing Your Appliance2nd stage Starting a FireBurning Process Kindling or 1st stageSlide Air Control Slide Left to Stop Automatic Combustion Control ACCFinal stage Opacity Manual Timer OverrideBurn Rates Burning GuidelinesDraft Problems TroubleshootingUnderstanding Vent Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? General Maintenance Creosote Chimney Cleaning Maintenance and Servicing the FireplaceDoor and Door Gasket Care and Cleaning of Plated SurfacesGlass Cleaning Disposal of AshesReplacement Maintenance Glass Replacement Maintenance Task ListFire Brick Configurations Firebrick ReplacementFan Cord Location Baffle Removal and InstallationFan Replacement Removing the fan Fan Replacement Instructions11 Timer Assembly Timer Assembly ReplacementLinkage Arm Slider Control Rod Timer Removal & Replacement20/11 Heatilator Constitution EPA Fireplace 480-1091D Date of Service Performed By Description of Service Service & Maintenance LogTypical Fireplace System Getting Started Installer GuideNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Selecting Fireplace Locations Framing & ClearancesClearances to Combustible Materials ClearancesOptional Framing Construction / Reduced Mantel Height Frame the FireplaceFan Wiring Diagram Electrical Access and Wiring DiagramInstallation of Fireplace Mm metal flex Fireplace Or rigid pipe Place Protective Metal Hearth Strips Secure the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ ReturnsAssemble the Chimney Sections Installing CAK4A and Flex PipeInstalling Flex Pipe Install Ceiling FirestopsSecure the Chimney Install Attic Insulation ShieldCut out Hole in Roof Double-check the Chimney AssemblyComplete Installation Install Flashing13 Multiple Chimney Locations Consult local codes for framing details SL-300 Series Ceiling/Roof ThimbleConstruct the Chase Chase InstallationsInstall Termination Cap Install Fireplace & ChimneyInstall Chase Top ST375 Square Termination Cap TCT375 Terra Cotta Cap = 1/k x inches of thickness FinishingHearth Extension Fireplace and Hearth Extension are flush on the floor Raised Hearth Extension FramingNon-Combustible Material Position the Hearth ExtensionFinishing Material Combustible MaterialCardboard or Metal Template MantelNon-Combustible Sealant Material 13 Complete installation Non-Combustible Facing Material Installa TionHeat Zone Kit Optional AccessoriesRun Length Cut Pipe 40 ft 6-12m 4 wall Firescreen Constitution Fireplace DimensionsReference Materials Catalog Description Catalog No Chimney Components15-3/4 DTO134 Part number list on following Service PartsStocked #3 Brick SetSide view Door Handle AssemblyThis page intentionally left blank Do not Discard this Manual Contact Information
Related manuals
Manual 71 pages 48.08 Kb

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.