FREESTANDING INSTALLATION
HEATER PLACEMENT:
Stove must be placed so that no combustibles are within, or can swing within (i.e. drapes doors), 36” of the heater.
If the stove is placed in a location where the ceiling height is less than 7’, it must follow the requirements in the section “Alcove Installation”.
FLOOR PROTECTION REQUIREMENTS:
Stove and floor protection must be installed on a level secure floor
The stove must be installed on a
Must extend under and 2” to each side of chimney tee (if used).
MINIMUM CLEARANCES TO COMBUSTIBLES
(Figures 12-17)
1” From Back Of Heater to Combustibles
10” From Front Side of Heater to Combustibles 1” From Back Corner of Heater to Combustibles 16” From Top Of Heater to Combustibles
3” From PL Vent to Combustibles
6” Non Combustible Surface In Front Of Heater 36” to drapes, doors, anything that can swing
CLEARANCES – “STRAIGHT INSTALLATION”: | INTERIOR VERTICAL |
THROUGH THE WALL |
12”
1”
1”
10” 10”
3”
10”
6”
6”
6”
Figure 12 |
| Figure 13 |
Copyright 2004 | 13 | Cheap Charlie Owner’s Manual |
Canadian Comfort Industries | www.dansons.com | Dansons Group Inc. |