Dansons Group HCS, HCF120, HCF300, HCJ manual Mobile Home Installation

Page 17

MOBILE HOME INSTALLATION

CAUTION: DO NOT INSTALL STOVE IN SLEEPING ROOM

THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR,

CEILING/ROOF MUST BE MAINTAINED!

Your Cheap Charlie stove has been tested and listed for mobile home installation. It may be installed in a mobile home as a "Free Standing Stove" or a "Hearth Stove", see detailed install and clearance requirements in these sections as they imply there.

In addition to all previously detailed installation requirements, mobile home installations must meet the following requirements:

Permanently bolt your stove to the floor, (A), figure 26.

Electrically ground your stove or the pedestal to the steel frame of the home. Use a number 8 gauge copper wire, (B), figure 26, or equivalent.

The stove must have a permanent outside air source with a ¼ inch screen over the inlet. Figure 25, (B, C & D)

For transportation all chimney/vent above the mobile home must be removed.

Chimney/PL Vent must be 3” or 4” PL Vent and must extend a minimum or 36” above the roofline of the mobile home and must be installed using a UL / ULC listed ceiling fire stop (J), figure 25, and rain cap (L), figure 25.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

L

K

J

A

Floor Pad

B

Combustion Air Intake

C

Fresh Air Duct

D

Fresh Air Hood

E

Stove Exhaust

F

Pipe Adapter

G

Clean Out Tee

H

Tee Support Bracket

I

Pipe

J

Firestop Spacer / Ceiling Support

K

Roof Flashing / Storm Collar

L

Rain Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E F

H

 

 

G

A

B

C D

 

 

Figure 25

 

Floor Pad

 

Floor

 

 

B (ground wire)

A (bolts)

Frame

Figure 26

 

 

Note: When moving your Mobile Home, all exterior venting must be removed while Mobile Home is being relocated. Upon completion of relocation all venting must be reinstalled and securely fastened.

Copyright 2004

17

Cheap Charlie Owner’s Manual

Canadian Comfort Industries

www.dansons.com

Dansons Group Inc.

Image 17
Contents Cheap Charlie Canadian Comfort Industries Dansons Group Inc Dear Cheap Charlie OwnerTable of Contents Safety Precautions Safety Precautions Specifications L250 High Limit Switch Automatic Safety FeaturesL120 LOW Limit Switch F140 FAN Limit SwitchRead this Entire Manual Before YOU Install and USE Your Installation OptionsInstallation Options Include Cheap Charlie Home & Shop HeaterInstallation Check List Exhaust Systems General Vent InstallationPellet Vent Type Venting DistanceVent Termination Clearances Pellet Vent Termination Figures 7Through The Wall Kits Include Outside AIRHeater Placement Freestanding InstallationFloor Protection Requirements Minimum Clearances to CombustiblesAlcove Installation Clearances Corner InstallationThrough the Wall Direct INSTALLATION. Figure COMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 19Mobile Home Installation HOW Your Cheap Charlie Heater Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeHOW the Board Works Basic OverviewShutting the Stove OFF Trim Pots Fine Tune Adjustments- Factory SettingsAuger Cycle FAN Speed Convection or heatingExcessive Combustion Air Damper Adjustment GuidelinePerformance Enhancement Tips Start Initial Appliance Burn SetupPellet Fuel Fine Tuning the Pellet Feed RatesPellet Quality Pellet ConsumptionPFI Pellet Standards FinesEvery 2 -3 Days / Weekly Required Routine CleaningCheck and Clean the Hopper Periodic MaintenancePeriodic Maintenance … Problem Solution Trouble ShootingExtended Warranty Limited WarrantyAppendix a INSERTING, Removing & Adjusting the Burn GrateBurn box Upper Grate LipAppendix a Burn Grate … Appendix B Damper Adjustment Guideline Lack of Combustion AirAppendix C Optional AccessoriesSee Your Cheap Charlie Dealer for Additional Info Replacement PartsAppendix D Operation Appendix EHigh / LOW Cycle Option Flashing 3 On / OFF Option Flashing 1Tools Needed Installation StepsTools Needed How to InstallPurpose Service & Maintenance Log