Dansons Group HCJ, HCF120, HCS, HCF300 manual Initial Appliance Burn Setup, Start

Page 23

INITIAL APPLIANCE BURN SETUP

IT IS CRITICAL FOR THE CORRECT OPERATION OF YOUR STOVE THAT THE BURN

GRATE, AIR INLET DAMPER, COMBUSTION FAN SPEED, AND

1 & 4 FUEL RATE BE SET CORRECTLY!

A HIGH QUALITY FIRE should burn with a brisk, yellow flame. A flame exhibiting a lazy, orange or sooty characteristic is a poor quality and inefficient flame. A poor flame produces less heat, increases sooting and may cause a smoky exhaust. If a poor flame exists for any period of time, clean your stove and exhaust system.

Note: if log option is purchased, do not install until initial setup is complete

FEED RATE

4

3

2

1

START

FEED RATE

START APPLIANCE AS PER LIGHTING INSTRUCTIONS,

let stove run for approx. 10 minutes before turning the stove to the # 4 setting (or High), to begin to make fine adjustments. AUGER CYCLE indicator should be lit “ON” for 3 seconds and “OFF” for 3-5 seconds. Adjust the AIR INLET DAMPER. This will have to be set, as the factory sends all units out with the damper wide open to accommodate a wide range of installations and elevations.

AIR INLET DAMPER: Slide open or close

 

 

 

 

damper as needed to obtain a fire that is brisk

 

 

Air Inlet

enough to carry ash out of the grate, but not so

 

 

 

 

Slide Rod

brisk that it carries pellets out as well (known as

 

 

 

 

“Pop corning”). Normally you should find that the

 

 

 

 

damper will need to be closed two-thirds to three

 

Rubber

quarters, but will vary with length of vent run, pellet

Stove Back Panel

GrometT

quality and elevation. The best way to set this is at

 

 

 

 

 

the FUEL SETTING #4.

 

Right Hand

 

 

Side Panel

FEED RATE

When you are pleased with the burn and how the appliance is operating, you

are now ready to set the board up at LOW setting.

 

 

4

 

 

Set FUEL RATE to #1 or LOW setting. Again let this burn for

 

 

 

approx. 10 minutes before making any adjustments. The AUGER

Decrease

Increase

3

CYCLE indicator should be “OFF” for approx 9 – 14 seconds

between auger turnings (light ON). If “Pop corning” is taking place

FINE TUNE ADJUSTMENTS

 

at this setting adjust the COMBUSTION FAN SPEED.

 

 

2

COMBUSTION FAN SPEED (Draft): In a few instances

 

 

 

because of prevailing conditions pertinent to your specific

1

4

1

installation, or even different batches of pellet fuel, the

COMBUSTION FAN SPEED may be adjusted to increase or

 

 

 

decrease the amount of air moving through the grate for the

 

FAN

 

cleanest burn. Fan speed can be adjusted by adjusting the FAN

 

START

 

 

trim pod COUNTER CLOCKWISE to INCREASE the speed and

 

 

FEED RATE

CLOCKWISE to DECREASE the speed of the combustion fan.

 

 

 

 

 

FUEL RATE: Fuel rate at the Lowest (number 1) and highest (number 4) settings can be changed by adjusting the #1 or #4 TRIM PODS located on the control panel. To INCREASE fuel rate turn trimmer COUNTER CLOCKWISE and to LOWER turn CLOCKWISE. To assist in knowing what changes you made, you should note the amount of time the light on the AUGER CYCLE stays “OFF”. (Note: The light stays “off” when ever the fuel feed motor is not running). Lengthening the time this light stays “OFF” lowers the fuel feed and shortening the “OFF” time increases the fuel feed. Factory Setting #1 light “OFF” is approx. 9-11 seconds, #4 light “OFF” is 3-4 seconds.

Copyright 2004

23

Cheap Charlie Owner’s Manual

Canadian Comfort Industries

www.dansons.com

Dansons Group Inc.

Image 23
Contents Cheap Charlie Canadian Comfort Industries Dansons Group Inc Dear Cheap Charlie OwnerTable of Contents Safety Precautions Safety Precautions Specifications F140 FAN Limit Switch Automatic Safety FeaturesL250 High Limit Switch L120 LOW Limit SwitchCheap Charlie Home & Shop Heater Installation OptionsRead this Entire Manual Before YOU Install and USE Your Installation Options IncludeInstallation Check List Venting Distance Vent InstallationExhaust Systems General Pellet Vent TypeVent Termination Clearances Pellet Vent Termination Figures 7Through The Wall Kits Include Outside AIRMinimum Clearances to Combustibles Freestanding InstallationHeater Placement Floor Protection RequirementsAlcove Installation Clearances Corner InstallationThrough the Wall Direct INSTALLATION. Figure COMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 19Mobile Home Installation HOW Your Cheap Charlie Heater Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeHOW the Board Works Basic OverviewFAN Speed Convection or heating Trim Pots Fine Tune Adjustments- Factory SettingsShutting the Stove OFF Auger CycleExcessive Combustion Air Damper Adjustment GuidelinePerformance Enhancement Tips Start Initial Appliance Burn SetupPellet Consumption Fine Tuning the Pellet Feed RatesPellet Fuel Pellet QualityPFI Pellet Standards FinesEvery 2 -3 Days / Weekly Required Routine CleaningCheck and Clean the Hopper Periodic MaintenancePeriodic Maintenance … Problem Solution Trouble ShootingExtended Warranty Limited WarrantyUpper Grate Lip INSERTING, Removing & Adjusting the Burn GrateAppendix a Burn boxAppendix a Burn Grate … Appendix B Damper Adjustment Guideline Lack of Combustion AirAppendix C Optional AccessoriesSee Your Cheap Charlie Dealer for Additional Info Replacement PartsAppendix D On / OFF Option Flashing 1 Appendix EOperation High / LOW Cycle Option Flashing 3Tools Needed Installation StepsTools Needed How to InstallPurpose Service & Maintenance Log