THE ACUTRON CONTROLS

as desired

Basic Overview

The AcuTron II or III digital control board was designed to give you flexibility on how you want to operate your stove. The AcuTron can be operated as a MANUAL control or by a THERMOSTAT. When operating in the Thermostat option, you can also choose to run your appliance in the ON/OFF mode or the LOW/HIGH mode.

The START or FEED RATE touch pad allows electricity to flow to your stove's electrical components for 15 minutes. If after 15 minutes your stove has heated to normal operating temperatures your stove will continue to run. If the fire does not light and/or burn properly, the electricity to your stove's components will be shut off at the end of 15 minutes.

The FAN SPEED controls the speed of the room air fan. This fan blows room air through the heat exchange tubes and back into the room. When the FEED RATE is set to a higher position, the FAN SPEED should be set higher and visa versa. To achieve optimum heat transfer it is recommended to set the FAN SPEED to LOW when running the FEED RATE at 1 or 2, and Fan on MED on FEED RATE #3 or 4.

When the START / FEED RATE is ON, the AUGER CYCLE LED will turn on when the auger is active. When the OFF touch pad is pushed [OFF], the auger motor will not run, fuel stops feeding and the fire will die.

The FEED RATE works in a synchronized manner setting both the fuel rate and combustion air at the same time. When fuel is increased by setting the FEED RATE higher, combustion air is automatically increased and visa versa.

HOW THE BOARD WORKS

INITIAL START OR SET-UP (MANUAL OR NON-THERMOSTAT MODE)

Upon initial start-up the control will feed automatically at the #1 feed rate.

Press the START touch pad.

-Convection (heating) fan will start and the FAN LED will be solid on LOW setting

-The 300 watt Auto-Igniter will begin to glow and the IGNITER LED will be solid

-The AUGER CYCLE LED will go solid for 3 seconds, indicating signal is being sent to the auger motor.

-The Combustion (exhaust) fan will start and operate at full speed for 60 seconds, then adjust downward to match feed rate #1.

Press FEED RATE touch pad to select desired heat output that you require upon completion of ignition sequence.

NOTE: If you do not press the FEED RATE touch pad, the stove will continue to run at FEED RATE #1 and the LED will continue to flash at a fast rate.

When the FEED RATE LED is flashing at a FAST rate this indicates that the LOW LIMIT (L120) is closed. This means the unit has not reached operating temperature.

When the FEED RATE LED is flashing at a SLOW rate this indicates that the LOW LIMIT (L120) is open. This means the control board has entered a 5 minute “Safety Delay” mode.

After the 5 minute Safety Delay is complete

-IGNITER and INGNITER LED will turn off

-FEED RATE LED will become solid and the appliance will feed fuel at your selected heat output

RE-START (MANUAL OR NON-THERMOSTAT MODE)

The AcuTron II or III board does have limited memory. To restart your appliance push the START touch pad. The appliance will automatically go through it normal start-up then return to the FEED and FAN setting you used prior to turning off the board and appliance the last time of use.

Copyright 2004

20

Cheap Charlie Owner’s Manual

Canadian Comfort Industries

www.dansons.com

Dansons Group Inc.

Image 20
Contents Cheap Charlie Dear Cheap Charlie Owner Canadian Comfort Industries Dansons Group IncTable of Contents Safety Precautions Safety Precautions Specifications Automatic Safety Features L250 High Limit SwitchL120 LOW Limit Switch F140 FAN Limit SwitchInstallation Options Read this Entire Manual Before YOU Install and USE YourInstallation Options Include Cheap Charlie Home & Shop HeaterInstallation Check List Vent Installation Exhaust Systems GeneralPellet Vent Type Venting DistancePellet Vent Termination Figures 7 Vent Termination ClearancesOutside AIR Through The Wall Kits IncludeFreestanding Installation Heater PlacementFloor Protection Requirements Minimum Clearances to CombustiblesClearances Corner Installation Alcove InstallationThrough the Wall Direct INSTALLATION. Figure Vertical Installations Figures 19 COMMON, but not inclusive, Vertical Installation Designs areMobile Home Installation Operating Your Stove HOW Your Cheap Charlie Heater WorksLighting stove manually No Igniter NON-Thermostat Mode Lighting Your StoveBasic Overview HOW the Board WorksTrim Pots Fine Tune Adjustments- Factory Settings Shutting the Stove OFFAuger Cycle FAN Speed Convection or heatingExcessive Combustion Air Damper Adjustment GuidelinePerformance Enhancement Tips Initial Appliance Burn Setup StartFine Tuning the Pellet Feed Rates Pellet FuelPellet Quality Pellet ConsumptionFines PFI Pellet StandardsRequired Routine Cleaning Every 2 -3 Days / WeeklyPeriodic Maintenance Check and Clean the HopperPeriodic Maintenance … Trouble Shooting Problem SolutionLimited Warranty Extended WarrantyINSERTING, Removing & Adjusting the Burn Grate Appendix aBurn box Upper Grate LipAppendix a Burn Grate … Damper Adjustment Guideline Lack of Combustion Air Appendix BOptional Accessories Appendix CSee Your Cheap Charlie Dealer for Additional Info Replacement PartsAppendix D Appendix E OperationHigh / LOW Cycle Option Flashing 3 On / OFF Option Flashing 1Installation Steps Tools NeededTools Needed How to InstallPurpose Service & Maintenance Log