INSTALLATION

Installing Heater Base Assembly (Cont.)

INSTALLATION

Continued

4.

Place logs in their proper position on heater base (see Installing

 

Logs, pages 15 through 17).

5.

Center heater base and logs front-to-back and side-to-side in

 

fireplace.

6.

Carefully remove logs without moving heater base.

7.

Mark screw locations through one hole on each side of the

 

mounting bracket (see Figures 13, 14 or 15, depending on your

 

model). If installing in a brick-bottom fireplace, mark screw

 

locations in mortar joint of bricks.

8.

Remove heater base from fireplace. If installing optional con-

 

trol accessories, do so at this time (Remote-Ready Models

 

Only). Follow all directions provided with accessory.

9.

Drill holes at marked locations using 3/16" drill bit.

VINTAGE OAK LOG CHASSIS

(Variable Manually-Controlled and

Thermostat-Controlled Models)

Masonry

Screw

Bracket with

Screw Holes

10. Attach base assembly to fireplace floor using two masonry

screws (in hardware package).

Heater Gas

Regulator

Fitting

Flexible Gas Hose (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator (Variable Manually-Controlled and Thermostat- Controlled Models Only)

Flexible Gas Hose (if allowed by local codes)

Fitting

Figure 13 - Attaching Heater to Fireplace Floor (Variable Manually- Controlled and Thermostat-Controlled Models Only)

Masonry

Screw

GOLDEN OAK MODEL CHASSIS

Bracket with

(Variable Manually-Controlled and

Screw Holes

Thermostat-Controlled Models)

 

Figure 14 - Attaching Base to Fireplace Floor (Remote-Ready Models Only)

Masonry

Screw

Figure 12 - Attaching Flexible Gas Hose to Heater (Remote-

Ready Models Only)

GOLDEN OAK MODEL CHASSIS

Bracket with

(Remote-Ready Models)

Screw Holes

 

Figure 15 - Attaching Base Assembly to Fireplace Floor

For..com

110399-01B

Image 12
Contents Unvented VENT-FREE GAS LOG Heater What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Optional Remote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors See options 1 and 2, . You can also remove door intoInstallation Check GAS TypeLOG Sizing Requirements Measured at 14 depthIf Not Using Mantel Minimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesDetermining Minimum Mantel Clearance Installing Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various StandardTrol accessories, do so at this time Remote-Ready Models Only. Follow all directions provided with accessoryDrill holes at marked locations using 3/16 drill bit Attach base assembly to fireplace floor using two masonryConnecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing gas Supply Piping system Checking GAS ConnectionsClose equipment shutoff valve see , Installing Logs Pressure Testing Heater Gas ConnectionsVintage Oak Two-Piece Log Set Installing Vintage Oak Two-Piece Log Set Golden Oak One-Piece Log SetInstalling Golden Oak 5-Piece Log Set Log Golden Oak Five-Piece Log SetOperating Heater Lighting InstructionsManual Lighting Procedure To Turn OFF GAS to ApplianceThermostat Control Operation Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Variable Control OperationFlame Adjustment Knob Optional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrcta Series OperationInspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs We also recommend that you keep the burner tube and pilotTroubleshooting Clean burner see Cleaning and Mainte ODS/pilot is partially clogged Clean ODS/pilot see Cleaning Gas odor even when control knob is in OFFLow line pressure CompanyOptional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceThermostat-Controlled Models Only Specifications Golden Oak Golden Oak 24 Remote-Ready 36 Remote-ReadyWiring Diagram Service HintsTechnical Service Replacement PartsAccessories Illustrated Parts Breakdown ODS Pilot Natural Gas ODS Pilot Propane/LPParts List Variable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG ModelsVariable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Parts Available not Shown QTY Natural Gas From drawing.4Parts Available not Shown THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Auxiliary Thermostat Mounting Clip REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models Parts List VYD36PNA and HD36NR Parts List For . .com Owners Registration Form Postage Required 110399-01B Warranty Information