Desa LAME-MAX Golden Oak Specifications, Golden Oak Golden Oak 24 Remote-Ready 36 Remote-Ready

Page 29

SPECIFICATIONS

29

SPECIFICATIONS

 

Vintage Oak 18" Variable

Vintage Oak 24" and 30"

Golden Oak 18" Variable

 

Manually-Controlled

Variable Manually-Controlled

Manually-Controlled

Btu (Variable)

16,000/27,000

20,000/31,500

16,000/30,000

Type Gas

Propane/LP Only - Natural

Propane/LP Only - Natural

Propane/LP Only - Natural

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

8.0" W.C. - 3.5" W.C.

8.0" W.C. - 3.5" W.C.

8.0" W.C. - 3.5" W.C.

Inlet Gas Pressure

 

 

 

(in. of water)

 

 

 

Maximum

14" - 10.5"

14" - 10.5"

14" - 10.5"

Minimum*

11" - 5"

11" - 5"

11" - 5"

Shipping Weight

36 lbs.

38 lbs.

26 lbs.

* For purpose of input adjustment

 

 

 

 

 

 

 

Golden Oak 24", 30"

 

 

 

and 36" Variable

Golden Oak 18"

Golden Oak 24" and 30"

 

Manually-Controlled

Thermostat-Controlled

Thermostat-Controlled

Btu (Variable)

20,000/39,000

20,000/33,000

21,500/36,000

Type Gas

Propane/LP Only - Natural

Propane/LP Only - Natural

Propane/LP Only - Natural

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

8.0" W.C. - 3.5" W.C.

8.0" W.C. - 3.5" W.C.

8.0" W.C. - 3.5" W.C.

Inlet Gas Pressure

 

 

 

(in. of water)

 

 

 

Maximum

14" - 10.5"

14" - 10.5"

14" - 10.5"

Minimum*

11" - 5"

11" - 5"

11" - 5"

Shipping Weight

28 lbs. (24"), 30 lbs. (30")

26 lbs.

28 lbs. (24"), 30 lbs. (30")

 

32 lbs. (36")

 

 

* For purpose of input adjustment

 

 

 

 

 

 

 

Golden Oak 18"

Golden Oak 24", 30"

 

Remote-Ready

and 36" Remote-Ready

Btu (Variable)

16,000/30,000

20,000/39,000

Type Gas

Propane/LP Only - Natural

Propane/LP Only - Natural

Ignition

Piezo

Piezo

Manifold Pressure

8.0" W.C. - 3.5" W.C.

8.0" W.C. - 3.5" W.C.

Inlet Gas Pressure

 

 

(in. of water)

 

 

Maximum

14" - 10.5"

14" - 10.5"

Minimum*

11" - 5"

11" - 5"

Shipping Weight

28 lbs.

30 lbs. (24")/32 lbs. (30")

 

 

34 lbs. (36”)

* For purpose of input adjustment

 

For morevisit www..com

110399-01B

Image 29
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsSafety Information Product Identification Optional Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors See options 1 and 2, . You can also remove door intoCheck GAS Type InstallationLOG Sizing Requirements Measured at 14 depthMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Mantel ClearancesFloor Clearances Installing Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various StandardOnly. Follow all directions provided with accessory Trol accessories, do so at this time Remote-Ready ModelsDrill holes at marked locations using 3/16 drill bit Attach base assembly to fireplace floor using two masonryExternal Regulator With Vent Pointing Down Connecting to GAS SupplyClose equipment shutoff valve see , Pressure Testing gas Supply Piping systemChecking GAS Connections Vintage Oak Two-Piece Log Set Installing LogsPressure Testing Heater Gas Connections Golden Oak One-Piece Log Set Installing Vintage Oak Two-Piece Log SetGolden Oak Five-Piece Log Set Installing Golden Oak 5-Piece Log Set LogLighting Instructions Operating HeaterTo Turn OFF GAS to Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off HeaterVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingFlame Adjustment Knob Thermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrcta Series OperationPilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs We also recommend that you keep the burner tube and pilotTroubleshooting Clean burner see Cleaning and Mainte Gas odor even when control knob is in OFF ODS/pilot is partially clogged Clean ODS/pilot see CleaningLow line pressure CompanyThermostat-Controlled Models Only Optional Positioning of Thermostat Sensing BulbFor Masonry and FACTORY-BUILT Metal Fireplace Golden Oak Golden Oak 24 Remote-Ready 36 Remote-Ready SpecificationsService Hints Wiring DiagramTechnical Service Replacement PartsAccessories ODS Pilot Natural Gas ODS Pilot Propane/LP Illustrated Parts BreakdownVariable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG Models Parts ListVariable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Parts Available not Shown QTY From drawing.4 Natural GasParts Available not Shown THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Auxiliary Thermostat Mounting Clip REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models Parts List VYD36PNA and HD36NR Parts List For . .com Owners Registration Form Postage Required 110399-01B Warranty Information