Desa LAME-MAX Golden Oak, FLAME-MAX VintageOak installation manual Parts List

Page 43

PARTS LIST

Remote-Ready Flame-Max®Golden Oak Log Models VYD18NRA, HD18NR, VYD24PNA, HD24NR, VYD30NRA, HD30NR, VYD36PNA and HD36NR

43

PARTS LIST

REMOTE-READY

FLAME-MAX®GOLDEN OAK LOG MODELS

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.

 

 

PART NUMBER FOR

 

 

 

 

 

 

 

 

 

 

 

 

KEY

VYD18NRA

VYD24NRA

VYD30NRA

VYD36NRA

 

 

 

NO.

HD18NR

HD24NR

HD30NR

HD36NR

DESCRIPTION

QTY.

 

1

110397-03

110397-04

110397-05

Five-Piece Golden Oak Log Set

1

 

1-1

110315-01

110313-01

110320-01

Front Log

1

 

1-2

110315-02

110313-02

110320-02

Rear Log

1

 

1-3

110315-03

110313-03

110320-03

Center Log

1

 

1-4

110315-04

110313-04

110320-04

Right Top Log

1

 

1-5

110315-05

110313-05

110320-05

 

Left Top Log

1

 

2

105268-01

105268-02

105268-03

107027-01

One-Piece Golden Oak Log Set

 

 

3

103779-01

103779-01

103779-01

103779-01

ODS Pilot (NG)

1

 

4

098249-01

098249-01

098249-01

098249-01

ODS Nut

2

 

5

104422-01

103342-01

103342-01

103342-01

Burner Outlet Tube

1

 

6

098264-02

098264-02

098264-02

098264-02

Male Connector (14396)

1

 

7

102843-01

102843-01

102843-01

102843-01

Burner Clip

1

 

8

099056-26

099056-16

099056-16

099056-16

Burner Orifice Injector

1

 

9

102966-01

102966-01

102966-01

Upper Bracket

1

 

10

102980-01

102772-01

102772-01

102772-01

Burner

1

 

11

099387-15

099387-12

099387-12

099387-12

Pilot Tube (Valve to regulator)

1

 

12

103781-01

103781-01

103781-01

103781-01

Gas Control Valve

1

 

13

103345-02

103345-01

103345-01

103345-01

Lower Bracket

1

 

14

M11084-38

M11084-38

M11084-38

M11084-38

Screw, #8 x .38

7

 

15

104384-01

102775-06CK

102775-08CK

102775-08CK

Painted Base Assy

1

 

16

098271-10

098271-10

098271-10

098271-10

Ignitor Cable

1

 

17

102445-01

102445-01

102445-01

102445-01

Piezo Ignitor (14261)

1

 

18

103587-02CK

103587-02CK

103587-02CK

103587-02CK

Plate, Switch

1

 

19

104099-01

104099-01

104099-01

104099-01

Heat Shield

1

 

20

098304-01

098304-01

098304-01

098304-01

Screw

2

 

21

103784-02

103784-02

103784-02

103784-02

Flame Adjustment Knob

1

 

22

103784-01

103784-01

103784-01

103784-01

Off-Pilot-On Knob

1

 

23

M12461-26

M12461-26

M12461-26

M12461-26

Screw, Hex Slt Wsr 10-32 x .38

4

 

24

100609-01

100609-01

100609-01

100609-01

Pilot Tube (Regulator to Pilot)

1

 

25

099918-02

099918-02

099918-02

099918-02

Pilot Regulator

1

 

26

103284-02

103284-02

103284-02

103284-02

Wiring Harness

1

 

27

099998-01

099998-01

099998-01

099998-01

Switch (14579)

1

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

100563-01

100563-01

100563-01

100563-01

Warning Plate

1

 

103877-01

103877-01

103877-01

103877-01

Lighting Instructions Plate

1

 

100565-01

100565-01

100565-01

100565-01

Warning Plate Fastener

1

 

100693-01

100639-01

100639-01

100639-01

Caution Decal

1

 

101137-02

101137-02

101137-02

101137-02

Hardware Kit

1

 

GA6060

GA6060

GA6060

GA6060

Lava Rock

1

 

 

 

 

 

 

 

For morevisit www..com

110399-01B

Image 43
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsSafety Information Unpacking Optional Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationSee options 1 and 2, . You can also remove door into Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsMeasured at 14 depth InstallationCheck GAS Type LOG Sizing RequirementsMinimum Noncombustible Material Clearances If Not Using MantelFloor Clearances Mantel ClearancesDetermining Minimum Mantel Clearance Area of Various Standard Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttach base assembly to fireplace floor using two masonry Trol accessories, do so at this time Remote-Ready ModelsOnly. Follow all directions provided with accessory Drill holes at marked locations using 3/16 drill bitExternal Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemClose equipment shutoff valve see , Pressure Testing Heater Gas Connections Installing LogsVintage Oak Two-Piece Log Set Golden Oak One-Piece Log Set Installing Vintage Oak Two-Piece Log SetGolden Oak Five-Piece Log Set Installing Golden Oak 5-Piece Log Set LogLighting Instructions Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Thermostat Control OperationVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingFlame Adjustment Knob Ghrcta Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesWe also recommend that you keep the burner tube and pilot Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsTroubleshooting Clean burner see Cleaning and Mainte Company ODS/pilot is partially clogged Clean ODS/pilot see CleaningGas odor even when control knob is in OFF Low line pressureFor Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbThermostat-Controlled Models Only Golden Oak Golden Oak 24 Remote-Ready 36 Remote-Ready SpecificationsReplacement Parts Wiring DiagramService Hints Technical ServiceAccessories ODS Pilot Natural Gas ODS Pilot Propane/LP Illustrated Parts BreakdownVariable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG Models Parts ListVariable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Parts Available not Shown QTY From drawing.4 Natural GasParts Available not Shown THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Auxiliary Thermostat Mounting Clip REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models Parts List VYD36PNA and HD36NR Parts List For . .com Owners Registration Form Postage Required 110399-01B Warranty Information