Desa FLAME-MAX VintageOak, LAME-MAX Golden Oak Operating Heater, Lighting Instructions

Page 18
C-clockwise

18

OPERATING HEATER (THERMOSTAT-CONTROLLED MODELS)

For Your Safety Read Before Lighting

Lighting Instructions

OPERATING HEATER

THERMOSTAT-CONTROLLED MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fire- place will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information column 1.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise to the PI- LOT position. Press in control knob for five (5) seconds (see Figure 30).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 19.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

 

 

Ignitor

Thermocouple

 

 

 

 

Pilot

 

 

Electrode

 

 

Burner

 

 

 

 

Ignitor

Control

 

 

 

Button

Knob

 

 

 

Figure 30 - Control Knob and

Figure 31- Pilot

 

Ignitor Button Location

(Note: Appearance of pilot

 

 

assembly may vary by model.)

For..com

110399-01B

Image 18
Contents Unvented VENT-FREE GAS LOG Heater What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Local Codes Optional Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building See options 1 and 2, . You can also remove door intoLOG Sizing Requirements InstallationCheck GAS Type Measured at 14 depthIf Not Using Mantel Minimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesDetermining Minimum Mantel Clearance Installation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various StandardDrill holes at marked locations using 3/16 drill bit Trol accessories, do so at this time Remote-Ready ModelsOnly. Follow all directions provided with accessory Attach base assembly to fireplace floor using two masonryConnecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing gas Supply Piping system Checking GAS ConnectionsClose equipment shutoff valve see , Installing Logs Pressure Testing Heater Gas ConnectionsVintage Oak Two-Piece Log Set Installing Vintage Oak Two-Piece Log Set Golden Oak One-Piece Log SetInstalling Golden Oak 5-Piece Log Set Log Golden Oak Five-Piece Log SetOperating Heater Lighting InstructionsThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Variable Control OperationFlame Adjustment Knob Ghrc Series Operation Optional Remote OperationThermostat Control Operation Ghrcta Series OperationBurner Primary AIR Holes Inspecting BurnersPilot Flame Pattern Main BurnerLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole We also recommend that you keep the burner tube and pilotTroubleshooting Clean burner see Cleaning and Mainte Low line pressure ODS/pilot is partially clogged Clean ODS/pilot see CleaningGas odor even when control knob is in OFF CompanyOptional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceThermostat-Controlled Models Only Specifications Golden Oak Golden Oak 24 Remote-Ready 36 Remote-ReadyTechnical Service Wiring DiagramService Hints Replacement PartsAccessories Illustrated Parts Breakdown ODS Pilot Natural Gas ODS Pilot Propane/LPParts List Variable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG ModelsVariable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Parts Available not Shown QTY Natural Gas From drawing.4Parts Available not Shown THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models Auxiliary Thermostat Mounting Clip REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models Parts List VYD36PNA and HD36NR Parts List For . .com Owners Registration Form Postage Required 110399-01B Warranty Information